Epoxy phosphonate crosslinkers for providing flame resistance to cotton textiles
- 6 June 2007
- journal article
- research article
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 18 (8) , 611-619
Abstract
Two new monomers (2‐methyl‐oxiranylmethyl)‐phosphonic acid dimethyl ester (3) and [2‐(dimethoxy‐phosphorylmethyl)‐oxyranylmethyl]‐phosphonic acid dimethyl ester (6) were prepared and used with dicyandiamide (7) and citric acid (8) to impart flame resistance to cotton plain weave, twill, and 80:20‐cotton/polyester fleece fabrics. Monomers 3 and 6 were prepared from methallyl chloride (1) and 3‐chloro‐2‐chloromethylpropene (4) respectively via a two‐step phosphorylation epoxidation sequence in 79.3 and 67.5% overall yields. 1H and 13C nuclear magnetic resonance (NMR) and gas chromatographic mass spectrometry (GCMS) data were used to confirm their structures. Decomposition of monomers 3 and 6 in nitrogen by thermogravimetric analysis (TGA) occurred at 110 and 220°C, respectively. The mixtures of 3:7:8 and 6:7:8 (in 2:1:1 ratio) exhibited peak‐curing temperatures by differential scanning calorimeter (DSC) at 125 and 150°C and the temperatures were deemed suitable for curing treated fabrics without marring them. Flame‐retardant treatments were applied by the pad‐dry‐cure methods. All untreated fabrics showed limiting oxygen index (LOI) values of about 18% oxygen in nitrogen. For formulations with monomer 3, LOI values for the three types of treated fabrics were greater than 25.5% when add‐on values for the formulation were 17.4, 12.7, and 21.1%. For formulations comprising monomer 6, LOI values were greater than 28.6% when add‐on values for the formulation were 18.3, 13.1, and 16.7%. With the formulation comprising monomer 3, the three fabrics passed the vertical flame test when add‐on values were 21.6, 12.7, and 23.5%, respectively; and with the formulation comprising monomer 6, they passed the vertical flame test when add‐on values were 13.8, 8.4, and 18.0%. In all cases char lengths of fabrics that passed the vertical flame test were less than 50% of original length and after‐flame time was 0 sec and after‐glow time was less than 2 sec. Published in 2007 by John Wiley & Sons, Ltd.Keywords
This publication has 17 references indexed in Scilit:
- Correlation between Limiting Oxygen Index and Phosphorus Content of the Cotton Fabric Treated with a Hydroxy-Functional Organophosphorus Flame Retarding Finish and Melamine–FormaldehydeJournal of Fire Sciences, 2004
- Substantive intumescence from phosphorylated 1,3‐propanediol derivatives substituted on to celluloseJournal of Applied Polymer Science, 2003
- Enhancing polymer flame retardancy by reaction with phosphorylated polyols. Part 2. Cellulose treated with a phosphonium salt urea condensate (proban CC®) flame retardantFire and Materials, 2002
- Pyrolytic Gas Generation of Cotton Cellulose With and Without Flame Retardants at Different Stages of Thermal Degradation: Effects of Nitrogen, Phosphorus, and HalogensTextile Research Journal, 2000
- Durable flame-retardant finished cotton fabrics characterized by thermal degradation behaviorsJournal of Applied Polymer Science, 1999
- Flame Retardation of Cellulosic Fibers as Characterized by Thermal Degradation BehaviorTextile Research Journal, 1998
- Isolation, Characterization, and Toxicological Aspects of Volatile Organophosphorus Compounds from the Combustion of Flame-Retarded Epoxy Resins with Phosphonate SubstructuresChemistry – A European Journal, 1998
- Halogen‐free flame‐retardant plastics for electronic applicationsJournal of Vinyl and Additive Technology, 1997
- Chemistry and Technology of Epoxy Resins1993
- Studies on the chars of flame-retardant phosphorylated cotton fibres containing transition metal ionsFire Safety Journal, 1989