Navzer (Nozar) D. Sachinvala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Navzer (Nozar) D. Sachinvala has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
David L. Winsor
Sucrochemistry Research Group, Hawaii Agriculture Research Center, New Orleans Office, Located at the SRRC, USDA-ARS, New Orleans, LA 70124, USA
2 shared publicationsNoelie R. Bertoniere
Cotton Textile Chemistry Research Unit, Southern Regional Research Center (SRRC), USDA-ARS, 1100 Robert E. Lee Blvd., New Orleans, LA 70124, USA
2 shared publicationsTyrone L. Vigo
Cotton Textile Chemistry Research Unit, Southern Regional Research Center (SRRC), USDA-ARS, 1100 Robert E. Lee Blvd., New Orleans, LA 70124, USA
2 shared publicationsCasey Grimm
Southern Regional Research Center, USDA-ARS, 1100 Robert E. Lee Blvd., New Orleans, LA 70124, USA
1 shared publicationD. V. Parikh
Southern Regional Research Center, USDA-ARS, 1100 Robert E. Lee Blvd., New Orleans, LA 70124, USA
1 shared publicationDharnidhar V. Parikh
Cotton Textile Chemistry Research Unit, United States Department of Agriculture, Agricultural Research Service, Southern Regional Research Center, 1100 Robert E. Lee Blvd., New Orleans, LA 70124, USA
1 shared publication
Latest Publications
- 6 June 2007
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 18 (8) , 611-619
Epoxy phosphonate crosslinkers for providing flame resistance to cotton textiles
Two new monomers (2‐methyl‐oxiranylmethyl)‐phosphonic acid dimethyl ester (3) and [2‐(dimethoxy‐phosphorylmethyl)‐oxyranylmethyl]‐phosphonic acid dimethyl ester (6) were prepared and used with dicyandiamide (7) and citric acid (8) to impart flame resistance to cotton plain weave, twill, and 80:20‐cotton/polyester fleece fabrics. Monomers 3 and 6 were prepared from methallyl chloride (1) and 3‐chloro‐2‐chloromethylpropene (4) respectively via a two‐step phosphorylation epoxidation sequence in 79.3 and 67.5% overall yields. 1H and 13C nuclear magnetic resonance (NMR) and gas chromatographic mass spectrometry (GCMS) data were used to confirm their structures. Decomposition of monomers 3 and 6 in nitrogen by thermogravimetric analysis (TGA) occurred at 110 and 220°C, respectively. The mixtures of 3:7:8 and 6:7:8 (in 2:1:1 ratio) exhibited peak‐curing temperatures by differential scanning calorimeter (DSC) at 125 and 150°C and the temperatures were deemed suitable for curing treated fabrics without marring them. Flame‐retardant treatments were applied by the pad‐dry‐cure methods. All untreated fabrics showed limiting oxygen index (LOI) values of about 18% oxygen in nitrogen. For formulations with monomer 3, LOI values for the three types of treated fabrics were greater than 25.5% when add‐on values for the formulation were 17.4, 12.7, and 21.1%. For formulations comprising monomer 6, LOI values were greater than 28.6% when add‐on values for the formulation were 18.3, 13.1, and 16.7%. With the formulation comprising monomer 3, the three fabrics passed the vertical flame test when add‐on values were 21.6, 12.7, and 23.5%, respectively; and with the formulation comprising monomer 6, they passed the vertical flame test when add‐on values were 13.8, 8.4, and 18.0%. In all cases char lengths of fabrics that passed the vertical flame test were less than 50% of original length and after‐flame time was 0 sec and after‐glow time was less than 2 sec. Published in 2007 by John Wiley & Sons, Ltd.
- 6 June 2007
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 18 (8) , 611-619
Epoxy phosphonate crosslinkers for providing flame resistance to cotton textiles
Two new monomers (2‐methyl‐oxiranylmethyl)‐phosphonic acid dimethyl ester (3) and [2‐(dimethoxy‐phosphorylmethyl)‐oxyranylmethyl]‐phosphonic acid dimethyl ester (6) were prepared and used with dicyandiamide (7) and citric acid (8) to impart flame resistance to cotton plain weave, twill, and 80:20‐cotton/polyester fleece fabrics. Monomers 3 and 6 were prepared from methallyl chloride (1) and 3‐chloro‐2‐chloromethylpropene (4) respectively via a two‐step phosphorylation epoxidation sequence in 79.3 and 67.5% overall yields. 1H and 13C nuclear magnetic resonance (NMR) and gas chromatographic mass spectrometry (GCMS) data were used to confirm their structures. Decomposition of monomers 3 and 6 in nitrogen by thermogravimetric analysis (TGA) occurred at 110 and 220°C, respectively. The mixtures of 3:7:8 and 6:7:8 (in 2:1:1 ratio) exhibited peak‐curing temperatures by differential scanning calorimeter (DSC) at 125 and 150°C and the temperatures were deemed suitable for curing treated fabrics without marring them. Flame‐retardant treatments were applied by the pad‐dry‐cure methods. All untreated fabrics showed limiting oxygen index (LOI) values of about 18% oxygen in nitrogen. For formulations with monomer 3, LOI values for the three types of treated fabrics were greater than 25.5% when add‐on values for the formulation were 17.4, 12.7, and 21.1%. For formulations comprising monomer 6, LOI values were greater than 28.6% when add‐on values for the formulation were 18.3, 13.1, and 16.7%. With the formulation comprising monomer 3, the three fabrics passed the vertical flame test when add‐on values were 21.6, 12.7, and 23.5%, respectively; and with the formulation comprising monomer 6, they passed the vertical flame test when add‐on values were 13.8, 8.4, and 18.0%. In all cases char lengths of fabrics that passed the vertical flame test were less than 50% of original length and after‐flame time was 0 sec and after‐glow time was less than 2 sec. Published in 2007 by John Wiley & Sons, Ltd.
- 7 May 2002
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 13 (6) , 413-427
Synthesis and NMR characterization of 6-Phenyl-6-deoxy-2,3-di-O-methylcellulose
- 7 May 2002
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 13 (6) , 413-427
Synthesis and NMR characterization of 6-Phenyl-6-deoxy-2,3-di-O-methylcellulose
- 31 December 2001
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 13 (1) , 66-79
Use of Sucrose‐based Epoxy Formulations and Cellulosic Fibers in the Design, Preparation, and Screening of New Composite Insulation Materials
Non‐woven composite insulation materials were generated from cotton, kenaf, jute, polyester, polypropylene, sucrose‐based epoxy formulations, and aluminum foil. The needlepunched fiber batts were rendered flame resistant by use of inorganic reagents and urea. To discover suitable epoxy formulations to bind the cellulose fibers to themselves or to dissimilar surfaces and to make flexible composites, a comparison of the performance of the known epoxy allyl sucroses (EAS), epoxy crotyl sucroses (ECS), and diglycidyl ether of bisphenol‐A (DGEBA) was made. The epoxies were cured with commercial diethylenetriamine (DETA), and UNIREZs‐2142 and 2355®, to discover a formulation with the following characteristics: (a) low cure temperature; (b) low Young's moduli and glass transition temperatures of cured thermosets for flexible composites; (c) ample bond strength between the fabric and the bonded surfaces; and (d) non‐cytotoxicity and non‐mutagenicity of the epoxies. Based on results following these criteria, EAS was selected, and the formulation comprising EAS and UNIREZ‐2355® was deemed suitable to bind fiber batts to surfaces of any type and geometry. ASTM guidelines were used to construct a wooden frame cube (heat box) for the simultaneous rapid screening of cellulosic fiber batts and composites. The new materials were compared against R‐19 fiberglass insulation for their ability to resist heat flow (denoted by relative R‐values) and time taken to approach thermal equilibrium. Plain non‐woven cellulosic fiber batts showed relative R‐values of 4.0 °F ft2 hr/Btu per inch thickness (0.27 K m2/W per cm), and took about 2 hr to establish equilibrium heat flow. Commercial fiberglass batts showed relative R‐valuesof 2.2 per in (0.15 per cm) and took 1 hr to attain equilibrium heat flow. When 6.25 in (15.9 cm) thick batts of fiberglass were needle punched to a thickness of 1 in (2.54 cm), relative R‐values and equilibrium heat flow times were 4.0 per in (0.27 per cm) and 2 hr, respectively. This denoted that the densities and thermal resistances of non‐conducting materials are raised concurrently. Anisotropic heat flow behavior was observed in cellulosic fiber composites with aluminum foil (shiny side out) bonded on one side. It depended upon whether the aluminum foil side or the fibers side faced the heat source. In the latter orientation the aluminum acted as a heat sink, and in the former orientation the foil acted as a poor heat reflector. The poor performance of these insulation composites was related to the fact that aluminum was directly bonded to the fiber batts and was acting as a heat conductor. When cellulose fiber shims (spacers) were placed between the fiber batts and the aluminum foil, the R‐values of the composites were comparable to those of plain batts but the times taken to approach thermal equilibrium increased to >3 hr, denoting that the foil was acting more as a reflector and less as a conductor. Copyright © 2001 John Wiley & Sons, Ltd.
- 31 December 2001
- Published by Wiley in Polymers for Advanced Technologies
- Vol. 13 (1) , 66-79
Use of Sucrose‐based Epoxy Formulations and Cellulosic Fibers in the Design, Preparation, and Screening of New Composite Insulation Materials
Non‐woven composite insulation materials were generated from cotton, kenaf, jute, polyester, polypropylene, sucrose‐based epoxy formulations, and aluminum foil. The needlepunched fiber batts were rendered flame resistant by use of inorganic reagents and urea. To discover suitable epoxy formulations to bind the cellulose fibers to themselves or to dissimilar surfaces and to make flexible composites, a comparison of the performance of the known epoxy allyl sucroses (EAS), epoxy crotyl sucroses (ECS), and diglycidyl ether of bisphenol‐A (DGEBA) was made. The epoxies were cured with commercial diethylenetriamine (DETA), and UNIREZs‐2142 and 2355®, to discover a formulation with the following characteristics: (a) low cure temperature; (b) low Young's moduli and glass transition temperatures of cured thermosets for flexible composites; (c) ample bond strength between the fabric and the bonded surfaces; and (d) non‐cytotoxicity and non‐mutagenicity of the epoxies. Based on results following these criteria, EAS was selected, and the formulation comprising EAS and UNIREZ‐2355® was deemed suitable to bind fiber batts to surfaces of any type and geometry. ASTM guidelines were used to construct a wooden frame cube (heat box) for the simultaneous rapid screening of cellulosic fiber batts and composites. The new materials were compared against R‐19 fiberglass insulation for their ability to resist heat flow (denoted by relative R‐values) and time taken to approach thermal equilibrium. Plain non‐woven cellulosic fiber batts showed relative R‐values of 4.0 °F ft2 hr/Btu per inch thickness (0.27 K m2/W per cm), and took about 2 hr to establish equilibrium heat flow. Commercial fiberglass batts showed relative R‐valuesof 2.2 per in (0.15 per cm) and took 1 hr to attain equilibrium heat flow. When 6.25 in (15.9 cm) thick batts of fiberglass were needle punched to a thickness of 1 in (2.54 cm), relative R‐values and equilibrium heat flow times were 4.0 per in (0.27 per cm) and 2 hr, respectively. This denoted that the densities and thermal resistances of non‐conducting materials are raised concurrently. Anisotropic heat flow behavior was observed in cellulosic fiber composites with aluminum foil (shiny side out) bonded on one side. It depended upon whether the aluminum foil side or the fibers side faced the heat source. In the latter orientation the aluminum acted as a heat sink, and in the former orientation the foil acted as a poor heat reflector. The poor performance of these insulation composites was related to the fact that aluminum was directly bonded to the fiber batts and was acting as a heat conductor. When cellulose fiber shims (spacers) were placed between the fiber batts and the aluminum foil, the R‐values of the composites were comparable to those of plain batts but the times taken to approach thermal equilibrium increased to >3 hr, denoting that the foil was acting more as a reflector and less as a conductor. Copyright © 2001 John Wiley & Sons, Ltd.