Abstract
Purpose: To establish peripheral nerve stimulation (PNS) thresholds for an ultra‐high performance magnetic field gradient subsystem (simultaneous 200‐mT/m gradient amplitude and 500‐T/m/s gradient slew rate; 1 MVA per axis [MAGNUS]) designed for neuroimaging with asymmetric transverse gradients and 42‐cm inner diameter, and to determine PNS threshold dependencies on gender, age, patient positioning within the gradient subsystem, and anatomical landmarks.Methods: The MAGNUS head gradient was installed in a whole‐body 3T scanner with a custom 16‐rung bird‐cage transmit/receive RF coil compatible with phased‐array receiver brain coils. Twenty adult subjects (10 male, mean ± SD age = 40.4 ± 11.1 years) underwent the imaging and PNS study. The tests were repeated by displacing subject positions by 2‐4 cm in the superior–inferior and anterior–posterior directions.Results: The x‐axis (left–right) yielded mostly facial stimulation, with mean ΔGmin = 111 ± 6 mT/m, chronaxie = 766 ± 76 µsec. The z‐axis (superior–inferior) yielded mostly chest/shoulder stimulation (123 ± 7 mT/m, 620 ± 62 µsec). Y‐axis (anterior–posterior) stimulation was negligible. X‐axis and z‐axis thresholds tended to increase with age, and there was negligible dependency with gender. Translation in the inferior and posterior directions tended to increase the x‐axis and z‐axis thresholds, respectively. Electric field simulations showed good agreement with the PNS results. Imaging at MAGNUS gradient performance with increased PNS threshold provided a 35% reduction in noise‐to‐diffusion contrast as compared with whole‐body performance (80 mT/m gradient amplitude, 200 T/m/sec gradient slew rate).Conclusion: The PNS threshold of MAGNUS is significantly higher than that for whole‐body gradients, which allows for diffusion gradients with short rise times (under 1 msec), important for interrogating brain microstructure length scales.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (NIH U01EB024450)
- U.S. Department of War (CDMRP W81XWH-16-2-0054)
- National Institute of Neurological Disorders and Stroke (NIH U01EB026976)
- National Cancer Institute (NIH R01EB010065, NIH R01CA190299)
This publication has 36 references indexed in Scilit:
- Improved correction for gradient nonlinearity effects in diffusion‐weighted imagingJournal of Magnetic Resonance Imaging, 2012
- Interaction of MRI field gradients with the human bodyPhysics in Medicine & Biology, 2009
- On the induced electric field gradients in the human body for magnetic stimulation by gradient coils in MRIIEEE Transactions on Biomedical Engineering, 2003
- Peripheral nerve stimulation properties of head and body gradient coils of various sizesMagnetic Resonance in Medicine, 2003
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002
- Measurements of Restricted Diffusion Using an Oscillating Gradient Spin-Echo SequenceJournal of Magnetic Resonance, 2000
- Simple but Reliable Solutions for Spiral MRI Gradient DesignJournal of Magnetic Resonance, 1999
- Designs for an asymmetric gradient set and a compact superconducting magnet for neural magnetic resonance imagingReview of Scientific Instruments, 1999
- A three-dimensional finite element method for computing magnetically induced currents in tissuesIEEE Transactions on Magnetics, 1994
- 4737716 Self-shielded gradient coils for nuclear magnetic resonance imagingMagnetic Resonance Imaging, 1989