Abstract
Hemoglobin A1c (HbA1c) plays a crucial role in diabetes management. We aimed to evaluate the analytical performance of a new enzymatic method kit for HbA1c measurement. The performance of the enzymatic method, including precision, accuracy, and linearity, was evaluated. Moreover, the interference effect from conventional interferents, Hb derivatives, Hb variants, and common drugs were assessed. In addition, the agreement of HbA1c results was compared between enzymatic methods, cation-exchange high-performance liquid chromatography (HPLC), and immunoassays. The intra-assay, between-assay, and total precision of HbA1c were all lower than 2%. HbA1c showed good linearity within the range of 3.96–20.23%. The enzymatic assay yielded results consistent with the external quality control samples, with a bias of less than ± 6% from the target values. The enzymatic method showed no interference from bilirubin, intralipid, vitamin C, Hb derivatives, common Hb variants, as well as antipyretic analgesics and hypoglycemic drugs. The HbA1c results of the enzymatic assay showed good agreement and accuracy compared to those obtained from the HPLC method and the immunoassay. The enzymatic method kit performed on the BS-600M chemistry analyzer is a reliable and robust method for measuring HbA1c. It is suitable for routine practice in clinical chemistry laboratories.Keywords
Funding Information
- Medical Science and Technology Foundation of Guangdong Province (B2021064)
This publication has 19 references indexed in Scilit:
- Application of biological variation and sigma metrics to evaluate the performance of HbA1c in external quality assessmentScandinavian Journal of Clinical and Laboratory Investigation, 2022
- Comparability of different methods of glycated hemoglobin measurement for samples of patients with variant and non-variant hemoglobinClinica Chimica Acta, 2022
- Analytical interference of 33 different hemoglobin variants on HbA1c measurements comparing high-performance liquid chromatography with whole blood enzymatic assay: A multi-center studyClinica Chimica Acta, 2022
- Unexpectedly low hemoglobin A1c in a patient with chronic lymphocytic leukemiaClinica Chimica Acta, 2022
- Setting analytical performance specifications using HbA1c as a model measurandClinica Chimica Acta, 2021
- Biological variability of glycated hemoglobinClinica Chimica Acta, 2010
- A Review of the Challenge in Measuring Hemoglobin A1cJournal of Diabetes Science and Technology, 2009
- A Review of Variant Hemoglobins Interfering with Hemoglobin A1c MeasurementJournal of Diabetes Science and Technology, 2009
- The effect of aspirin and vitamins C and E on HbA1c assaysClinica Chimica Acta, 2006
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusThe New England journal of medicine, 1993