Anping Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Anping Xu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Han Chen
Department of Clinical Laboratory, Wuhan Asia General Hospital Affiliated to Wuhan University of Science and Technology, Wuhan, China
1 shared publication- Helu Liu
Department of Laboratory Medicine, Shenzhen Integrated Traditional Chinese and Western Medicine Hospital, Shenzhen, China
1 shared publication Hui Wang
Department of Clinical Laboratory, Wuhan Asia General Hospital Affiliated to Wuhan University of Science and Technology, Wuhan, China
1 shared publication- Ling Ji
Department of Laboratory Medicine , 74573 Peking University Shenzhen Hospital , Shenzhen , Guangdong , P.R. China
1 shared publication Mingyang Li
Department of Laboratory Medicine, Peking University Shenzhen Hospital, Shenzhen, China
1 shared publicationWeijie Xie
Department of Laboratory Medicine, Peking University Shenzhen Hospital, Shenzhen, China
1 shared publication
Latest Publications
- Open Access
- 29 May 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-7
Analytical performance evaluation of the Mindray enzymatic assay for hemoglobin A1c measurement
Hemoglobin A1c (HbA1c) plays a crucial role in diabetes management. We aimed to evaluate the analytical performance of a new enzymatic method kit for HbA1c measurement. The performance of the enzymatic method, including precision, accuracy, and linearity, was evaluated. Moreover, the interference effect from conventional interferents, Hb derivatives, Hb variants, and common drugs were assessed. In addition, the agreement of HbA1c results was compared between enzymatic methods, cation-exchange high-performance liquid chromatography (HPLC), and immunoassays. The intra-assay, between-assay, and total precision of HbA1c were all lower than 2%. HbA1c showed good linearity within the range of 3.96–20.23%. The enzymatic assay yielded results consistent with the external quality control samples, with a bias of less than ± 6% from the target values. The enzymatic method showed no interference from bilirubin, intralipid, vitamin C, Hb derivatives, common Hb variants, as well as antipyretic analgesics and hypoglycemic drugs. The HbA1c results of the enzymatic assay showed good agreement and accuracy compared to those obtained from the HPLC method and the immunoassay. The enzymatic method kit performed on the BS-600M chemistry analyzer is a reliable and robust method for measuring HbA1c. It is suitable for routine practice in clinical chemistry laboratories.
- 29 May 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-7
Open AccessAnalytical performance evaluation of the Mindray enzymatic assay for hemoglobin A1c measurement
Hemoglobin A1c (HbA1c) plays a crucial role in diabetes management. We aimed to evaluate the analytical performance of a new enzymatic method kit for HbA1c measurement. The performance of the enzymatic method, including precision, accuracy, and linearity, was evaluated. Moreover, the interference effect from conventional interferents, Hb derivatives, Hb variants, and common drugs were assessed. In addition, the agreement of HbA1c results was compared between enzymatic methods, cation-exchange high-performance liquid chromatography (HPLC), and immunoassays. The intra-assay, between-assay, and total precision of HbA1c were all lower than 2%. HbA1c showed good linearity within the range of 3.96–20.23%. The enzymatic assay yielded results consistent with the external quality control samples, with a bias of less than ± 6% from the target values. The enzymatic method showed no interference from bilirubin, intralipid, vitamin C, Hb derivatives, common Hb variants, as well as antipyretic analgesics and hypoglycemic drugs. The HbA1c results of the enzymatic assay showed good agreement and accuracy compared to those obtained from the HPLC method and the immunoassay. The enzymatic method kit performed on the BS-600M chemistry analyzer is a reliable and robust method for measuring HbA1c. It is suitable for routine practice in clinical chemistry laboratories.