Experimental Study on the Response of Hand-Transmitted Vibration from an EVA Power Tool
Open Access
Abstract
The objective of this paper is to accurately measure the vibration response of tools and hands by simulating the hand-held power tools, which are operated by astronauts wearing extravehicular spacesuit gloves under microgravity conditions. The total vibration value and the daily vibration exposure of the subject’s hand are obtained. The results show that the opisthenar is more sensitive to the vibration frequency less than 200 Hz. After frequency weighting, the vibration exposure in the composite state of wearing an unpressurized spacesuit glove on the opisthenar is 23.6% greater than the vibration exposure of the palm, and for the bare hand, the percentage is 25.1% under the same condition. Because the operation time of tightening a screw is longer than that of loosening, the tightening operation performed by wearing spacesuit gloves produces 15.7% more mean vibration exposure on the palm and opisthenar than the loosening operation. The results of vibration transmissibility characterized by the total vibration weighted method and the total vibration unweighted method are 0.039 and 0.094, respectively. In comparison with bare hands, the mean daily vibration exposure on the palm and opisthenar in the composite state by wearing spacesuit gloves is 16.3% less, indicating that the unpressurized spacesuit gloves have an effect on vibration reduction. The research reveals the law of hand-transmitted vibration caused by the coupling of the extravehicular activities (EVA) power tools and spacesuit gloves, and provides a novel method for further similar tests and verification of hand-held EVA power tools.Keywords
Funding Information
- the CAST Science Foundation for Distinguished Young Scholars of China (R-WY-JQRC-19)
This publication has 20 references indexed in Scilit:
- Space Station Solar Array Joint RepairMaterials Performance and Characterization, 2015
- Modeling of the biodynamic responses distributed at the fingers and palm of the hand in three orthogonal directionsJournal of Sound and Vibration, 2013
- Methods for deriving a representative biodynamic response of the hand–arm system to vibrationJournal of Sound and Vibration, 2009
- Characteristics of hand-transmitted vibration of a hand tractor used in three operational modesInternational Journal of Industrial Ergonomics, 2009
- Hand-transmitted vibration in power tools: Accomplishment of standards and users’ perceptionInternational Journal of Industrial Ergonomics, 2008
- Modeling of biodynamic responses distributed at the fingers and the palm of the human hand–arm systemJournal of Biomechanics, 2007
- Biodynamic Response of Human Fingers in a Power Grip Subjected to a Random VibrationJournal of Biomechanical Engineering, 2004
- Effectiveness of a Transfer Function Method for Evaluating Vibration Isolation Performance of Gloves When Used with Chipping HammersJournal of Low Frequency Noise, Vibration and Active Control, 2002
- Main problems of the Russian Orlan-M space suit utilization for EVAs on the ISS.Acta Astronautica, 2001
- Comparison of different measures for hand–arm vibration exposureSafety Science, 1998