Yang Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yang Yu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hao Fu
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China
2 shared publications - Minghe Jin
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China
2 shared publications - Yang Chen
Beijing Institute of Spacecraft Environment Engineering, Beijing 100094, China
2 shared publications Hao Fu
Beijing Institute of Spacecraft Environment Engineering
1 shared publication- Peng Zheng
Beijing Institute of Spacecraft Environment Engineering, Beijing 100094, China
1 shared publication Tingting Wu
Beijing Institute of Spacecraft Environment Engineering
1 shared publication
Latest Publications
- 29 September 2024
- Published by Springer Nature
- p. 333-340
Application of Mass Cancellation Method for Mechanical Impedance Measurement of Hand-Arm System Under Microgravity Simulation
- 29 September 2024
- Published by Springer Nature
- p. 333-340
Application of Mass Cancellation Method for Mechanical Impedance Measurement of Hand-Arm System Under Microgravity Simulation
- Open Access
- 14 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10373
Research on Hand-Transmitted Vibration Prediction Model of the Handheld EVA Power Tool
The hand-transmitted vibration generated by extravehicular activity (EVA) power tools has an important impact on the health of astronauts and the efficient completion of maintenance tasks when astronauts use EVA power tools for on-orbit maintenance. Based on the hand-transmitted vibration zero-gravity simulation test platform to measure the vibration response of the EVA power tool to human hands. Given the influence of the length of the operating rod and the number of non-detaching fastening devices on daily vibration exposure when astronauts wear extravehicular spacesuit gloves, a second-order polynomial model and a quadratic cumulative nonlinear model of daily vibration exposure are established. The experimental results show that the second-order polynomial model is more explanatory and predictive of the test data in the scope of the test. The R-values of the palm and opisthenar prediction model are 0.9930 and 0.9940 respectively, and the RMSEs are m/s2 and m/s2. The quadratic cumulative nonlinear model can accurately predict the vibration exposure of the hand outside the scope of the test. This study can provide theoretical reference and data support for the prediction of vibration exposure generated by astronauts using the EVA power tools during on-orbit maintenance.- 14 October 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (20) , 10373
Open AccessResearch on Hand-Transmitted Vibration Prediction Model of the Handheld EVA Power Tool
The hand-transmitted vibration generated by extravehicular activity (EVA) power tools has an important impact on the health of astronauts and the efficient completion of maintenance tasks when astronauts use EVA power tools for on-orbit maintenance. Based on the hand-transmitted vibration zero-gravity simulation test platform to measure the vibration response of the EVA power tool to human hands. Given the influence of the length of the operating rod and the number of non-detaching fastening devices on daily vibration exposure when astronauts wear extravehicular spacesuit gloves, a second-order polynomial model and a quadratic cumulative nonlinear model of daily vibration exposure are established. The experimental results show that the second-order polynomial model is more explanatory and predictive of the test data in the scope of the test. The R-values of the palm and opisthenar prediction model are 0.9930 and 0.9940 respectively, and the RMSEs are m/s2 and m/s2. The quadratic cumulative nonlinear model can accurately predict the vibration exposure of the hand outside the scope of the test. This study can provide theoretical reference and data support for the prediction of vibration exposure generated by astronauts using the EVA power tools during on-orbit maintenance. - Open Access
Experimental Study on the Response of Hand-Transmitted Vibration from an EVA Power Tool
The objective of this paper is to accurately measure the vibration response of tools and hands by simulating the hand-held power tools, which are operated by astronauts wearing extravehicular spacesuit gloves under microgravity conditions. The total vibration value and the daily vibration exposure of the subject’s hand are obtained. The results show that the opisthenar is more sensitive to the vibration frequency less than 200 Hz. After frequency weighting, the vibration exposure in the composite state of wearing an unpressurized spacesuit glove on the opisthenar is 23.6% greater than the vibration exposure of the palm, and for the bare hand, the percentage is 25.1% under the same condition. Because the operation time of tightening a screw is longer than that of loosening, the tightening operation performed by wearing spacesuit gloves produces 15.7% more mean vibration exposure on the palm and opisthenar than the loosening operation. The results of vibration transmissibility characterized by the total vibration weighted method and the total vibration unweighted method are 0.039 and 0.094, respectively. In comparison with bare hands, the mean daily vibration exposure on the palm and opisthenar in the composite state by wearing spacesuit gloves is 16.3% less, indicating that the unpressurized spacesuit gloves have an effect on vibration reduction. The research reveals the law of hand-transmitted vibration caused by the coupling of the extravehicular activities (EVA) power tools and spacesuit gloves, and provides a novel method for further similar tests and verification of hand-held EVA power tools.
Open AccessExperimental Study on the Response of Hand-Transmitted Vibration from an EVA Power Tool
The objective of this paper is to accurately measure the vibration response of tools and hands by simulating the hand-held power tools, which are operated by astronauts wearing extravehicular spacesuit gloves under microgravity conditions. The total vibration value and the daily vibration exposure of the subject’s hand are obtained. The results show that the opisthenar is more sensitive to the vibration frequency less than 200 Hz. After frequency weighting, the vibration exposure in the composite state of wearing an unpressurized spacesuit glove on the opisthenar is 23.6% greater than the vibration exposure of the palm, and for the bare hand, the percentage is 25.1% under the same condition. Because the operation time of tightening a screw is longer than that of loosening, the tightening operation performed by wearing spacesuit gloves produces 15.7% more mean vibration exposure on the palm and opisthenar than the loosening operation. The results of vibration transmissibility characterized by the total vibration weighted method and the total vibration unweighted method are 0.039 and 0.094, respectively. In comparison with bare hands, the mean daily vibration exposure on the palm and opisthenar in the composite state by wearing spacesuit gloves is 16.3% less, indicating that the unpressurized spacesuit gloves have an effect on vibration reduction. The research reveals the law of hand-transmitted vibration caused by the coupling of the extravehicular activities (EVA) power tools and spacesuit gloves, and provides a novel method for further similar tests and verification of hand-held EVA power tools.