Body morphometry appropriate computational phantoms for dose and risk optimization in pediatric renal imaging with Tc-99m DMSA and Tc-99m MAG3
- 25 November 2020
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 65 (23) , 235026
Abstract
Current guidelines for administered activity (AA) in pediatric nuclear medicine imaging studies are based on a 2016 harmonization of the 2010 North American Consensus guidelines and the 2007 European Association of Nuclear Medicine pediatric dosage card. These guidelines assign AA scaled to patient body mass, with further constraints on maximum and minimum values of radiopharmaceutical activity. These guidelines, however, are not formulated based upon a rigor-ous evaluation of diagnostic image quality. In a recent study of the renal cortex imaging agent 99mTc-DMSA (Li Y et al 2019), body mass-based dosing guidelines were shown to not give the same level of image quality for patients of differing body mass. Their data suggest that patient girth at the level of the kidneys may be a better morphometric parameter to consider when selecting AA for renal nuclear medicine imaging. The objective of the present work was thus to develop a dedicated series of computational phantoms to support image quality and organ dose studies in pediatric renal imaging using 99mTc-DMSA or 99mTc-MAG3. The final library consists of 50 male and female phantoms of ages 0 to 15 years, with percentile variations (5th to 95th) in waist circumference (WC) at each age. For each phantom, nominal values of kidney volume, length, and depth were incorporated into the phantom design. Organ absorbed doses, detriment-weighted doses, and stochastic risks were assessed using ICRP reference biokinetic models for both agents. In Monte Carlo radiation transport simulations, organ doses for these agents yielded detriment-weighted dose coefficients (mSv/MBq) that were in general larger than current ICRP values of the effective dose coefficients (age and WC-averaged ratios of eDW/e were 1.40 for the male phantoms and 1.49 for the female phantoms). Values of risk index (ratio of radiation-induced to natural background cancer incidence risk x 100) varied between 0.062 (newborns) to 0.108 (15-year-olds) for 99mTc-DMSA and between 0.026 (newborns) to 0.122 (15-year-olds) for 99mTc-MAG3. Using tallies of photon exit fluence as a rough surrogate for uniform image quality, our study demonstrated that through body region-of-interest optimization of AA, there is the potential for further dose and risk reductions of between factors of 1.5 to 3.0 beyond simple weight-based dosing guidance.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (R01 EB013558)
This publication has 16 references indexed in Scilit:
- Current pediatric administered activity guidelines for 99mTc‐DMSA SPECT based on patient weight do not provide the same task‐based image qualityMedical Physics, 2019
- A projection image database to investigate factors affecting image quality in weight-based dosing: application to pediatric renal SPECTPhysics in Medicine & Biology, 2018
- Biokinetics, dosimetry, and radiation risk in infants after 99mTc-MAG3 scansEJNMMI Research, 2018
- Features of Particle and Heavy Ion Transport code System (PHITS) version 3.02Journal of Nuclear Science and Technology, 2018
- A risk index for pediatric patients undergoing diagnostic imaging with99mTc-dimercaptosuccinic acid that accounts for body habitusPhysics in Medicine & Biology, 2016
- Pediatric Radiopharmaceutical Administration: Harmonization of the 2007 EANM Paediatric Dosage Card (Version 1.5.2008) and the 2010 North American Consensus guidelineEuropean Journal of Nuclear Medicine and Molecular Imaging, 2014
- RadRAT: a radiation risk assessment tool for lifetime cancer risk projectionJournal of Radiological Protection, 2012
- Automatic Measurement of Renal Volume in Children Using 99mTc Dimercaptosuccinic Acid SPECTClinical Nuclear Medicine, 2012
- An Approach for Balancing Diagnostic Image Quality with Cancer Risk: Application to Pediatric Diagnostic Imaging of 99mTc-Dimercaptosuccinic AcidJournal of Nuclear Medicine, 2011
- The UF family of reference hybrid phantoms for computational radiation dosimetryPhysics in Medicine & Biology, 2009