XCXinhua Cao

Xinhua Cao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xinhua Cao has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of dynamic contrast-enhanced MRI versus MAG-3 scintigraphy for differential renal function assessment in pediatric patients

    by Cemre Ariyurek, Liam Timms, Xinhua Cao, Karen Sarao, Onur Afacan, Neha Kwatra, Jeanne S. Chow, Sila Kurugol

    Background Measuring differential renal function (DRF) is critical for managing children with congenital and acquired urological diseases. MAG-3 renal scintigraphy is the most widely used clinical technique; dynamic contrast-enhanced MRI (DCE-MRI) provides a radiation-free and high-resolution alternative method for assessing DRF. Objective To evaluate the agreement between DRF values derived from DCE-MRI and MAG-3 scintigraphy-derived DRF in pediatric patients. Materials and methods This retrospective study included 23 pediatric patients (age range, 3 months-20 years; mean±SD, 8.3±7.4 years) who underwent DCE-MRI embedded in MR urography (MRU) protocol and MAG-3 studies within 6 months. DCE-MRI was performed using a golden-angle radial dynamic stack-of-stars acquisition with golden-angle sparse parallel (GRASP) reconstruction, and analyzed the renal filtration rate with a two-compartment tracer kinetic model. DRF values from DCE-MRI were compared with those from MAG-3, using both default (n=23) and C-shaped background regions for MAG-3 analysis, where raw data were available (n=16). Agreement was evaluated using Bland–Altman analysis, Pearson and concordance correlations, and paired statistical tests. Results With default MAG-3 background analysis (n=23), mean DRF difference (MAG-3 minus DCE-MRI) was 0.4% (95% CI, -3.3% to 4.2%), with 95% limits of agreement of -16.7% to +17.5%. Concordance correlation coefficient (CCC) was 0.870 (95% CI, 0.718–0.942). Within the pre-defined clinically acceptable margin of ±10%, 78.3% (18/23) of cases fell, with a mean absolute difference of 6.1%. With C-shaped background subtraction in the subset with available raw MAG-3 data (n=16), mean difference was -2.3% (95% CI, -6.7% to 2.0%), limits of agreement -18.3% to +13.6%, and CCC 0.845 (95% CI, 0.614–0.943). Pearson correlation was strong in both analyses (n=23: r=0.872, 95% CI, 0.719–0.945; n=16: r=0.866, 95% CI, 0.648–0.953; both P<0.001). No clinically significant systematic or proportional bias was detected in either analysis. Conclusion DCE-MRI demonstrates strong linear association and concordance with MAG-3 scintigraphy for pediatric differential renal function assessment with no clinically significant systematic bias, though the observed measurement variability indicates caution is warranted when comparing values near surgical decision thresholds. C-shaped background correction is recommended for MAG-3 in hydronephrotic kidneys to optimize inter-modality agreement. Graphical Abstract The alternative text for this image may have been generated using AI.

  • Weight-based determination of administered activity in 99mTc-DMSA renal SPECT in infants: are minimum administered activities necessary?

    by Neha Kwatra, P. Hendrik Pretorius, S. Ted Treves, Reza Vali, Valentina Ferrer Valencia, Weibin Fu, Xinhua Cao, Yongyi Yang, Michael King, Frederic H. Fahey

    Background The North American consensus guidelines recommend a weight-based administered activity for renal cortical scintigraphy with 99mTc-dimercaptosuccinic acid (DMSA; 1.85 MBq/kg or 0.05 mCi/kg). Patients weighing less than 10 kg are recommended to receive a minimum administered activity of 18.5 MBq (0.5 mCi), irrespective of their weight. This approach is presumably to provide sufficient counts for adequate image quality, but it has not been rigorously evaluated. Objective To compare the adequacy of image quality of infant DMSA renal SPECT examinations obtained using the minimum administered activity recommended by the consensus guidelines with simulated data utilizing a strict weight-based dosage. Materials and methods Phase 1: Datasets of 55 infants (29 females, 26 males, median age 3.0 months and weight 5.6 kg) undergoing DMSA SPECT from 2016 to 2021 were identified with 7 used for training and 48 used for study analysis. Data from patients receiving the administered activity recommended by the consensus guidelines (“full dosage”, group A) were processed using binomial resampling to add Poisson noise to mimic a strict weight-based scheme (“simulated reduced dosage”, group A′). Three experienced nuclear medicine physicians, who were blinded to group membership and clinical information, independently evaluated adequacy of image quality for clinical interpretation on a 4-point scale. Student’s paired t-test was utilized for group comparisons and inter-rater agreements were calculated using kappa statistics. Phase 2: Group A′ simulated data were compared to a second cohort of 99mTc-DMSA SPECT cases where the administered activity followed a strict weight-based regime (“true reduced dosage”, group B). Subjects weighing between 4-7 kg were selected (group A′, 10 patients, 4 females, 6 males, median age 3.00 months and weight 5.35 kg) to compare with similar-weight group B subjects (10 patients, 5 females, 5 males, median age 2.50 months and weight 6.05 kg). The same observers and 4-point scale from phase 1 were used. The Wilcoxon rank sum test was utilized for analysis. Results Observers’ ratings were combined for analysis resulting in n=144 case-pairs (3 observers × 48 case-pairs) in phase 1. In phase 1, the ratings of groups A and A′ were identical for 73.6% (106/144) of case-pairs and never differed by more than ±1 level. No significant rating difference was found between the groups (mean (SD) of 1.17 (0.93) versus 1.22 (0.98), P=0.20). Similarly, in phase 2, no significant rating difference was found between groups A′ and B (mean (SD) of 0.80 (0.81) versus 0.50 (0.68), P=0.14). Conclusion There was no significant difference in the adequacy of image quality of 99mTc-DMSA SPECT examinations using a strict weight-based dosage compared to using the recommended minimum dosage for infants as small as 3 kg. Graphical Abstract


  • Open Access

    Strategies for creation of data reserve and stress testing of medical AI products

    by Huai Chen, Yanmei Tie, Xinhua Cao, Geoffrey S. Young, Xiaoyin Xu

    With the fast development of artificial intelligence (AI) and its applications in medicine, it is often said that the time for intelligent medicine is arriving, if not already have arrived. While there is no doubt that AI-centred intelligent medicine will transform current healthcare, it is necessary to test and re-test medical AI (MAI) products before they are implemented in the real world. From the perspective of ensuring safety, accuracy and efficiency, it is imperative that MAIs undergo stress tests in a systematic and comprehensive manner where stress tests subject MAIs to workloads and environments beyond tests carried out by their developers. In such stress tests, potential bottlenecks or failures of MAIs may be identified and fed back to developers to optimise the products. To avoid bias and ensure fairness, stress tests should be prepared and administered by an independent body.


  • Development and autoregulation of kidney function in children: a retrospective study using 99mTc-MAG3 renography

    by Xinhua Cao, Xiaoyin Xu, S. Ted Treves, Laura A. Drubach, Neha Kwatra, Min Zhang, Frederic H. Fahey, David A. Diamond, Stephan D. Voss

    Background Both the development of kidney function in healthy children and autoregulation ability of kidney function in patients with asymmetric kidneys are important in clinical diagnosis and treatment of kidney-related diseases, but there are however only limited studies. This study aimed to investigate development of kidney function in normal children with healthy symmetric kidneys and autoregulation of the healthy kidney compensating the functional loss of a diseased one in children with asymmetric kidneys. Methods Two hundred thirty-seven children (156 male, 81 female) from 0 to 20y (average 4.6y ± 5.1) undergoing 99mTc-MAG3 renography were included, comprising 134 with healthy symmetrically functioning kidneys and 103 with asymmetric kidneys. Clearance was calculated from kidney uptakes at 1–2 min. A developmental model between MAG3 clearance (CL) and patient age in normal group was identified (CL = 84.39Age0.395 ml/min, r = 0.957, p < 0.001). The clearance autoregulation rate in abnormal group with asymmetric kidneys was defined as the ratio of the measured MAG3 clearance and the normal value predicted from the renal developmental model of normal group. Results No significant difference of MAG3 clearance (p = 0.723) was found between independent abnormal group and normal group. The autoregulation rate of kidney clearance in abnormal group was 94.2% on average, and no significant differences were found between two age groups (p = 0.49), male and female (p = 0.39), and left kidney and right kidney (p = 0.92) but two different grades of asymmetric kidneys (p = 0.02). Conclusions The healthy kidney of two asymmetric kidneys can automatically regulate total kidney function up to 94% of two symmetric kidneys in normal children. Graphical abstract


  • DeepAMO: a multi-slice, multi-view anthropomorphic model observer for visual detection tasks performed on volume images

    by Ye Li, Junyu Chen, Justin L. Brown, S. Ted Treves, Xinhua Cao, Frederic H. Fahey, George Sgouros, Wesley E. Bolch, Eric C. Frey

    The Journal of Medical Imaging allows for the peer-reviewed communication and archiving of fundamental and translational research, as well as applications, focused on medical imaging, a field that continues to benefit from technological improvements and yield biomedical advancements in the early detection, diagnostics, and therapy of disease as well as in the understanding of normal conditions.


  • Dosimetric considerations of99mTc-MDP uptake within the epiphyseal plates of the long bones of pediatric patients

    by Justin L Brown, Briana Sexton-Stallone, Ye Li, Eric C Frey, S Ted Treves, Frederic H Fahey, Donika Plyku, Xinhua Cao, Chansoo Choi, Chan Hyeong Kim, et al.

    Skeletal scintigraphy is most performed in pediatric patients using the radiopharmaceutical 99m Tc labelled methylene diphosphonate ( 99m Tc-MDP). Reference biokinetic models for 99m Tc-MDP indicate 50% of the administered activity is uniformly localized to the interior bone surfaces (trabecular and cortical regions), yet imaging data clearly show some preferential uptake to the epiphyseal growth plates of the long bones. To explore the dosimetric consequences of these regional activity concentrations, we have modified mesh-type computational phantoms of the International Commission on Radiological Protection (ICRP) reference pediatric series to explicitly include geometric models of the epiphyseal growth plates (2 mm in thickness) within the left/right, distal/proximal ends of the humeri, radii, ulnae, femora, tibia, and fibulae. Bone mineral activity from the ICRP Publication 128 biokinetic model for 99m Tc-MDP (ICRP 2015) was then partitioned to the growth plates at values of 0.5%, 4.4%, 8.3%, 12.2%, 16.1%, and 20%. Radiation transport simulations were performed to compute 99m Tc S-values and organ dose coefficients to the soft tissues and to bone site-specific regions of spongiosa. As the percentage of bone activity assigned to the growth plates was increased (from 0.5% to 20%), absorbed doses to the soft tissue organs, active bone marrow, bone endosteum (BE), as well as the detriment-weighted dose, were shown to decrease from their nominal values (no substantial growth plate activity), while epiphyseal plate self-doses increased. In the 15 year old male phantom, moving from 0.5% to 20% relative bone activity within the epiphyseal plates resulted in a 15% reduction in active marrow (AM) and BE dose, a 10% reduction in mean soft tissue and detriment-weighted dose, and a 6.3-fold increase in epiphyseal plate self-dose. In the newborn female phantom, we observed a 18% decrease in AM and BE dose, a 10% decrease in mean soft tissue dose, a 15% decrease in detriment-weighted dose, and 12.8-fold increase in epiphyseal plate self-dose. Increases (to 3 mm) and decreases (to 1 mm) in the assumed growth plate thickness of our models were shown to impact only the growth plate self-dose. Future work in differential quantification of 99m Tc-MDP activity—growth plates versus other bone surfaces—is required to provide clinically realistic data on activity partitioning as a function of patient age, and perhaps skeletal site. The phantom series presented here may be used to develop more optimized age-related guidance on 99m Tc-MDP administered activities to children.


  • Body morphometry appropriate computational phantoms for dose and risk optimization in pediatric renal imaging with Tc-99m DMSA and Tc-99m MAG3

    by Justin L Brown, Briana Sexton-Stallone, Ye Li, Eric C Frey, S Ted Treves, Frederic H Fahey, Donika Plyku, Xinhua Cao, George Sgouros, Wesley E Bolch

    Current guidelines for administered activity (AA) in pediatric nuclear medicine imaging studies are based on a 2016 harmonization of the 2010 North American Consensus guidelines and the 2007 European Association of Nuclear Medicine pediatric dosage card. These guidelines assign AA scaled to patient body mass, with further constraints on maximum and minimum values of radiopharmaceutical activity. These guidelines, however, are not formulated based upon a rigor-ous evaluation of diagnostic image quality. In a recent study of the renal cortex imaging agent 99mTc-DMSA (Li Y et al 2019), body mass-based dosing guidelines were shown to not give the same level of image quality for patients of differing body mass. Their data suggest that patient girth at the level of the kidneys may be a better morphometric parameter to consider when selecting AA for renal nuclear medicine imaging. The objective of the present work was thus to develop a dedicated series of computational phantoms to support image quality and organ dose studies in pediatric renal imaging using 99mTc-DMSA or 99mTc-MAG3. The final library consists of 50 male and female phantoms of ages 0 to 15 years, with percentile variations (5th to 95th) in waist circumference (WC) at each age. For each phantom, nominal values of kidney volume, length, and depth were incorporated into the phantom design. Organ absorbed doses, detriment-weighted doses, and stochastic risks were assessed using ICRP reference biokinetic models for both agents. In Monte Carlo radiation transport simulations, organ doses for these agents yielded detriment-weighted dose coefficients (mSv/MBq) that were in general larger than current ICRP values of the effective dose coefficients (age and WC-averaged ratios of eDW/e were 1.40 for the male phantoms and 1.49 for the female phantoms). Values of risk index (ratio of radiation-induced to natural background cancer incidence risk x 100) varied between 0.062 (newborns) to 0.108 (15-year-olds) for 99mTc-DMSA and between 0.026 (newborns) to 0.122 (15-year-olds) for 99mTc-MAG3. Using tallies of photon exit fluence as a rough surrogate for uniform image quality, our study demonstrated that through body region-of-interest optimization of AA, there is the potential for further dose and risk reductions of between factors of 1.5 to 3.0 beyond simple weight-based dosing guidance.


  • Stomach frame-count-based attenuation correction of dynamic posterior view gastric emptying scintigraphy with continuous acquisition in children

    by Xinhua Cao, Xiaoyin Xu, Laura Drubach, Frederic H. Fahey

    When performing dynamic gastric emptying scintigraphy with continuous acquisition in children, a single posterior view acquisition is preferred because it allows the young patient to more easily interact with a parent or technologist even though this method tends toward overestimating gastric emptying.

  • Estimation of Split Renal Function With 99mTc-DMSA SPECT: Comparison Between 3D Volumetric Assessment and 2D Coronal Projection Imaging

    by Xinhua Cao, Xiaoyin Xu, Frederick D. Grant, S. Ted Treves

    OBJECTIVE. Split renal function (SRF) can be estimated with 99mTc-labeled dimercaptosuccinic acid (DMSA) SPECT cortical renal scintigraphy on either 2D projected images or 3D images. The purpose of this study was to determine whether there is a significant difference between SRF values calculated with the 2D method and those calculated with the 3D method. MATERIALS AND METHODS. This retrospective study was performed with 99mTc-DMSA SPECT images of 316 patients (age range, 1–26 years). All images were reconstructed by filtered back projection. An automated computational method was developed to estimate SRF using both 2D projection images and direct 3D images. A paired t test was used to evaluate the difference between SRFs determined with the two methods and the association between the magnitude of the differences and kidney size, patient age, and SRF. RESULTS. There was strong correlation between SRFs estimated with the 2D and 3D methods (r = 0.94, p < 0.001). There was small significant difference (0.14%...


  • Beyond current guidelines: reduction in minimum administered radiopharmaceutical activity with preserved diagnostic image quality in pediatric hepatobiliary scintigraphy

    by Frederic Fahey, Katherine Zukotynski, David Zurakowski, Robert Markelewicz, Anthony Falone, Marie Vitello, Xinhua Cao, Frederick Grant, Laura Drubach, A. Hans Vija, et al.

    To determine if the minimum administered radiopharmaceutical activity for hepatobiliary scintigraphy can be reduced while preserving diagnostic image quality using enhanced planar processing (EPP).