Investigation of PolyVinyl Chloride Plastisol Tissue-Mimicking Phantoms for MR- and Ultrasound-Elastography
Authors:
Open Access
- 22 December 2020
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 8
Abstract
Objective: Realistic tissue-mimicking phantoms are essential for the development, the investigation and the calibration of medical imaging techniques and protocols. Because it requires taking both mechanical and imaging properties into account, the development of robust, calibrated phantoms is a major challenge in elastography. Soft polyvinyl chloride gels in a liquid plasticizer (plastisol or PVCP) have been proposed as soft tissue-mimicking phantoms (TMP) for elasticity imaging. PVCP phantoms are relatively low-cost and can be easily stored over long time periods without any specific requirements. In this work, the preparation of a PVCP gel phantom for both MR and ultrasound-elastography is proposed and its acoustic, NMR and mechanical properties are studied.Materials and methods: The acoustic and magnetic resonance imaging properties of PVCP are measured for different mass ratios between ultrasound speckle particles and PVCP solution, and between resin and plasticizer. The linear mechanical properties of plastisol samples are then investigated over time using not only indentation tests, but also MR and ultrasound-elastography clinical protocols. These properties are compared to typical values reported for biological soft tissues and to the values found in the literature for PVCP gels.Results and conclusions: After a period of two weeks, the mechanical properties of the plastisol samples measured with indentation testing are stable for at least the following 4 weeks (end of follow-up period 43 days after gelation-fusion). Neither the mechanical nor the NMR properties of plastisol gels were found to be affected by the addition of cellulose as acoustic speckle. Mechanical properties of the proposed gels were successfully characterized by clinical, commercially-available MR Elastography and sonoelastography protocols. PVCP with a mass ratio of ultrasound speckle particles of 0.6%–0.8% and a mass ratio between resin and plasticizer between 50 and 70% appears as a good TMP candidate that can be used with both MR and ultrasound-based elastography methods.Keywords
All Related Versions
Funding Information
- Agence Nationale de la Recherche (ANR-10-IAHU-02, ANR-11-LABX-004, ANR-10-IDEX-0002-02)
This publication has 72 references indexed in Scilit:
- Development and Application of Stable Phantoms for the Evaluation of Photoacoustic Imaging InstrumentsPLOS ONE, 2013
- Characterization of a hyper-viscoelastic phantom mimicking biological soft tissue using an abdominal pneumatic driver with magnetic resonance elastography (MRE)Journal of Biomechanics, 2012
- Viscoelastic properties of soft gels: comparison of magnetic resonance elastography and dynamic shear testing in the shear wave regimePhysics in Medicine & Biology, 2011
- Nonlinear elastic behavior of phantom materials for elastographyPhysics in Medicine & Biology, 2010
- High‐frequency mode conversion technique for stiff lesion detection with magnetic resonance elastography (MRE)Magnetic Resonance in Medicine, 2009
- Cross‐validation of magnetic resonance elastography and ultrasound‐based transient elastography: A preliminary phantom studyJournal of Magnetic Resonance Imaging, 2009
- Anisotropic mechanical properties of magnetically aligned fibrin gels measured by magnetic resonance elastographyJournal of Biomechanics, 2009
- MR elastography as a method for the assessment of myocardial stiffness: Comparison with an established pressure–volume model in a left ventricular model of the heartMagnetic Resonance in Medicine, 2009
- Role of Ultrasonic Shear Rate Estimation Errors in Assessing Inflammatory Response and Vascular RiskUltrasound in Medicine & Biology, 2008
- Vickers Indentation Curves of Magnesium Oxide (MgO)Journal of Tribology, 1984