Abstract
This paper reports the comprehensive thermodynamic modeling of a modified combustion gas turbine plant where Brayton refrigeration cycle was employed for inlet air cooling along with evaporative after cooling. Exergetic evaluation was combined with the emission computation to ascertain the effects of operating variables like extraction pressure ratio, extracted mass rate, turbine inlet temperature (TIT), ambient relative humidity, and mass of injected water on the thermo-environmental performance of the gas turbine cycle. Investigation of the proposed gas turbine cycle revealed an exergetic output of 33%, compared to 29% for base case. Proposed modification in basic gas turbine shows a drastic reduction in cycle's exergy loss from 24% to 3% with a considerable decrease in the percentage of local irreversibility of the compressor from 5% to 3% along with a rise in combustion irreversibility from 19% to 21%. The environmental advantage of adding evaporative after cooling to gas turbine cycle along with inlet air cooling can be seen from the significant reduction of NOx from 40 g/kg of fuel to 1 × 10−9 g/kg of fuel with the moderate increase of CO concentration from 36 g/kg of fuel to 99 g/kg of fuel when the fuel–air equivalence ratio reduces from 1.0 to 0.3. Emission assessment further reveals that the increase in ambient relative humidity from 20% to 80% causes a considerable reduction in NOx concentration from 9.5 to 5.8 g/kg of fuel while showing a negligible raise in CO concentration from 4.4 to 5.0 g/kg of fuel.Keywords
This publication has 26 references indexed in Scilit:
- Exergy Analysis of Overspray Process in Gas Turbine SystemsEnergies, 2012
- Greenhouse gas emission and exergo-environmental analyses of a trigeneration energy systemInternational Journal of Greenhouse Gas Control, 2011
- Exergy analysis of the regenerative gas turbine cycle using absorption inlet cooling and evaporative aftercoolingJournal of the Energy Institute, 2009
- Energy and Exergy Analysis of Simple and Regenerative Gas Turbines Inlet Air Cooling Using Absorption RefrigerationJournal of Applied Sciences, 2009
- Energy and exergy analysis of reverse Brayton refrigerator for Gas Turbine power boostingInternational Journal of Exergy, 2009
- Energy and exergy analyses of compressor inlet air-cooled gas turbines using the Joule—Brayton refrigeration cycleProceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 2008
- Thermodynamic performance assessment of an indirect intercooled reheat regenerative gas turbine cycle with inlet air cooling and evaporative aftercooling of the compressor dischargeInternational Journal of Energy Research, 2006
- Performance enhancement of gas turbines by inlet air-cooling in hot and humid climatesInternational Journal of Energy Research, 2006
- Thermodynamic assessment of power requirements and impact of different gas-turbine inlet air cooling techniques at two different locations in OmanApplied Thermal Engineering, 2005
- Fundamentals of exergy analysis, entropy generation minimization, and the generation of flow architectureInternational Journal of Energy Research, 2002