AKAbdul Khaliq

Abdul Khaliq

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abdul Khaliq has a total of 20 co-authors. Here are the top co-authors by number of shared publications:

  • Rajesh Kumar

    Department of Mechanical Engineering, Delhi Technological University, Delhi, India

    4 shared publications
  • Esmail Mohamed Ali Mokheimer

    Mechanical Engineering Department, King Fahd University of Petroleum and Minerals (KFUPM), Dhahran, Saudi Arabia

    3 shared publications
  • Eydhah Almatrafi

    Center of Research Excellence in Renewable Energy and Power Systems, Center of Excellence in Desalination Technology, Department of Mechanical Engineering, Faculty of Engineering-Rabigh, King Abdulaziz University, Jeddah 21589, Saudi Arabia

    2 shared publications
  • Farrukh Khalid

    Advanced Clean Energy Systems (ACES) Laboratory, School of Energy Science and Engineering, Indian Institute of Technology Guwahati, Guwahati 781039, India

    2 shared publications
  • Ibrahim Dincer

    University of Ontario Institute of Technology Faculty of Engineering and Applied Science 2000 Simcoe Street North , Oshawa L1H7K4 ON , Canada

    2 shared publications
  • Mathkar A. Alharthi

    Department of Chemical Engineering, College of Engineering at Yanbu, Taibah University, P.O. Box 4050, Yanbu Al-Bahr 41911, Saudi Arabia

    2 shared publications

Latest Publications

  • Development and Assessment of the Performance of a Novel Parabolic Trough Solar Collector-Driven Three-Stage Cooling Cycle

    by Tawfiq Al-Mughanam, Abdul Khaliq

    A gaseous flow is employed as heat transfer fluid (HTF) in a parabolic trough solar collector (PTSC) for simultaneous production of cooling at three different levels of temperature to meet the demands of air conditioning, refrigeration, and ultra-low-temperature refrigeration required to ensure the efficacy of some special vaccines. The combined system consists of five subsystems including PTSC, Kalina cycle (KC), ejector refrigeration cycle (ERC), cascaded refrigeration cycle (CRC), and absorption refrigeration cycle (ARC). A simulation through an engineering equation solver (EES) is conducted to assess the impact of internal tube diameter of absorber and solar irradiation on rise of HTF temperature and mass flowrate of Kalina cycle fluid. It is determined that for given solar irradiation, the temperature of HTF goes down when internal diameter of absorber tube is enlarged. The influence of weather conditions; solar irradiation and ambient temperature, type of HTF, and concentration of ammonia–water basic solution on thermal and exergy efficiencies of three-stage cooling cycle (TSC) are examined. The TSC with helium-operated PTSC delivers better results than air and CO2. Exergy analysis shows that solar collector (30.26%) dissipates the highest exergy, followed by the ejector (12.5%) and vapor generator subsystem (7.61%). The type of CRC fluid pair affects TSC cycle refrigeration capacity and cooling exergy efficiency. The promotion of solar irradiation from 850 to 1200 W/m2 increases the cooling exergy efficiency of the three-stage cycle from 6.72% to 9.52% when the evaporator temperature is set at −45 °C and CRC employs NH3-propylene.


  • Open Access

    Proposal and Investigation of a New Tower Solar Collector-Based Trigeneration Energy System

    by Eydhah Almatrafi, Abdul Khaliq, Rajesh Kumar, Ahmad Bamasag, Muhammad Ehtisham Siddiqui

    These days, the low efficiency of solar-based thermal power plants results in uneconomical performance and high-cost uncompetitive industries compared with conventional fossil fuels. In order to overcome such issues, a novel combined cooling–power–heating (trigeneration) system is proposed and analyzed in this paper. This system uses an ammonia–water binary mixture as a working fluid and a solar heat source to produce diverse types of energy for a multi-unit building in a sustainable fashion. In addition to the basic cooling–power cogeneration cycle, a flashing chamber that will boost the flow rate of refrigerant without any additional heat supply is employed. By developing a mathematical model, the system performance is analyzed using varying parameters of solar irradiation, hot oil temperature, process heat pressure, and ambient temperature to investigate the influence on electrical power, cooling capacity, refrigeration exergy, energy utilization factor (EUF), and system exergy efficiency. Increasing direct normal irradiation (DNI) from 500 W/m2 to 1000 W/m2 reduces the system EUF and exergy efficiency from 53.62% to 43.12% and from 49.02% to 25.65%, respectively. Both power and refrigeration exergy increase with increasing DNI and ambient temperature, while heating exergy remains constant. It is demonstrated that of 100% solar energy supplied, 46.03% is converted into energetic output and 53.97% is recorded as energy loss. The solar exergy supplied is distributed into 8.34% produced exergy, 29.78% exergy loss, and the remaining 61.88% is the destructed exergy. The highest destruction of solar exergy (56.89%) occurs in the central receiver.


  • Investigation of a Combined Refrigeration and Air Conditioning System Based on Two-Phase Ejector Driven by Exhaust Gases of Natural Gas Fueled Homogeneous Charge Compression Ignition Engine

    by Abdul Khaliq, Bandar A. Almohammadi, Mathkar A. Alharthi, Mohd Asjad Siddiqui, Rajesh Kumar

    A natural gas-fueled homogeneous charge compression ignition (HCCI) engine is coupled to an exhaust gas operated turbine driven two-phase ejector cycle to generate power and cooling energy, simultaneously. By establishing a thermodynamic model, the simulation of the proposed system and its parametric analyses are conducted. Energetic and exergetic investigations are carried out to study the role of equivalence ratio, engine speed, condenser temperature, refrigeration evaporator temperature, air-conditioning evaporator temperature, and ejector nozzle efficiency on the thermodynamic performance parameters of the combined cycle. The analysis of two-phase ejector cooling cycle using three working fluids including R717, R290, and R600a is conducted. Results reveal that the thermal efficiency of HCCI engine is increased from 47.44% to 49.94%, and for the R600a operated combined cycle it is increased from 60.05% to 63.26% when the equivalence ratio is promoted from 0.3 to 0.6. Distribution of fuel exergy results show that out of 100% exergy input, in case of R717 operated combined cycle, 139.79 kW (38.72%) is the total exergy output, and 164.21 kW (45.49%) and 57 kW (15.79%) are the values for exergy destruction and exergy losses. It is further shown that change in refrigerant minorly influence the percentages of exergy distribution.


  • Thermodynamic and Comparative Analysis of Ejector Refrigeration Cycle and Absorption Refrigeration Cycle Integrated Wet Ethanol-Fueled HCCI Engine for Cogeneration of Power and Cooling

    by Mohd Asjad Siddiqui, Abdul Khaliq, Rajesh Kumar

    This study attempted for the proposal and analysis of a combined cycle that consists of a wet ethanol-fueled and turbocharged homogeneous charge compression ignition (HCCI) engine coupled to ejector refrigeration cycle (ERC) and absorption refrigeration cycle (ARC) for the simultaneous generation of two distinct outputs, namely, power and refrigeration. Both first and second laws of thermodynamics were employed to develop a thermodynamic model, which has been applied to investigate the performance of combined cycle. Furthermore, performance of the combined cycle for ERC versus ARC was compared and assessed after altering operating parameters (turbocharger pressure ratio, turbocharger compressor efficiency, ambient temperature, and the entrainment ratio of ERC and generator temperature of ARC) to study their effect on engine power output, refrigeration load, exergy of refrigeration, and energy and exergy efficiencies of the cooling-power cogeneration cycle. Results show that the elevated pressure of turbocharger results in the enhancement of HCCI engine power and increase of the refrigeration of thermal load, simultaneously. However, the increasing ambient temperature shows the decline of HCCI engine efficiencies and energy efficiency of cogeneration, while the cogeneration cycle exergy efficiency is found increasing. Furthermore, the results are reported for the refrigeration performed by lithium bromide–water (LiBr–H2O)-operated ARC, and R134a- and R290-operated ERC, respectively. Mapping of exergy destruction for the presented cogeneration cycle discovered HCCI engine, boiler of ERC, generator of ARC, and catalytic convertor as the components of significant exergy destruction. Entrainment ratio and type of refrigerant employed in ERC and the generator temperature of ARC show a marginal impact on the COPs of these cycles.


  • Investigation of a Novel Solar Powered Trigeneration System for Simultaneous Production of Electricity, Heating, and Refrigeration Below Freezing

    by Eydhah Almatrafi, Abdul Khaliq

    A solar powered trigeneration system consisting of tower solar collector, Kalina cycle with the heat exchanger, and ejector-absorption refrigeration cycle is proposed to produce refrigeration below freezing, electricity, and process heat, simultaneously. Simulation through computational fluid dynamics using ansys-fluent package is conducted to examine the effect of coil diameter and inlet oil temperature on the pressure and temperature of solar heat transfer fluid. It is found that, for inlet temperature of 92 °C and direct normal irradiations of 850 W/m2, the solar heat transfer fluid outlet temperature increases by 9% when the coil diameter increased from 150 to 400 mm. Trigeneration performance is analyzed after altering hot oil outlet temperature, turbine inlet pressure, and the concentration of ammonia–water basic solution to study their effect on power produced by turbine, refrigeration load, exergy of refrigeration, and efficiencies of trigeneration system. An increase in the concentration of the ammonia–water basic solution is leading toward the significant increase in the turbine power and the elevation of trigeneration system’s energy and exergy efficiencies. Bottoming of the Kalina cycle with ejector-absorption refrigeration cycle shows the distribution of solar energy as energetic output 72.31% and energy lost to environment 27.69%. The solar exergy supplied to the trigeneration system is distributed as follows: 16.23% is the exergy produced, 1.62% is the exergy loss, and 82.15% is the exergy destroyed.


  • Analysis and Assessment of Tower Solar Collector Driven Trigeneration System

    by Abdul Khaliq, Mathkar A. Alharthi, Saeed Alqaed, Esmail M. A. Mokheimer, Rajesh Kumar

    This paper describes the development and performance assessment of a tower solar collector driven integrated system operating in trigeneration mode to generate electricity, heating, and cooling, in a carbon-free manner. The proposed system applies a heliostat-based central receiver unit as a base of solar energy input to drive the steam Rankine cycle which is combined with the process heater and the lithium bromide-water operated absorption chiller. An analysis is performed to monitor the behavior of energy and exergy efficiency at various operating conditions of the proposed trigeneration system. The computed results are authenticated with the reported literature. A comparison is made between the present findings and reported results in the form of exergy efficiency, total exergy destroyed, and energy efficiency. Consideration of process heat and cold along with electricity provides a promising increase in energy efficiency from 15.8% to 64.1% while the exergy efficiency is enhanced from 16.9% to 24.4%. Variation in direct normal irradiations from 600 W/m2 to 1000 W/m2 results in the significant rise of energetic and exergetic outcomes of the proposed trigeneration system. Out of 100% solar exergy supplied to the proposed trigeneration, 24% is generated as the exergetic output, 1.6% is lost to ambient, and the remaining 74.4% is the exergy destroyed in the system components.


  • Performance Analysis of a Solar-Powered Multi-Effect Refrigeration System

    by Ayman J. Alazazmeh, Esmail M. A. Mokheimer, Abdul Khaliq, Bilal A. Qureshi

    The main objective of the current work is to investigate the thermodynamic performance of a novel solar powered multi-effect refrigeration system. The proposed cycle consists of a solar tower system with a heliostat field and central receiver (CR) that has molten salt as the heat transfer fluid, an absorption refrigeration cycle (ARC), an ejector refrigeration cycle (ERC), and a cascade refrigeration cycle (CRC). Energy and exergy analyses were carried out to measure the thermodynamic performance of the proposed cycle, using Dhahran weather data and operating conditions. The largest contribution to cycle irreversibility was found to be from the CR system (52.5%), followed by the heliostat field (25%). The first and second-law efficiencies improved due to the increase in the following parameters: ejector evaporator temperature, turbine inlet and exit pressures, and cascade evaporator temperature. Parametric analysis showed that the compressor delivery pressure, turbine inlet and exit pressures, hot molten salt outlet temperature, and ejector evaporator temperature significantly affect the refrigeration output.


  • A Thermo-Environmental Evaluation of a Modified Combustion Gas Turbine Plant

    by Abdul Khaliq, M. A. Habib, Keshavendra Choudhary

    This paper reports the comprehensive thermodynamic modeling of a modified combustion gas turbine plant where Brayton refrigeration cycle was employed for inlet air cooling along with evaporative after cooling. Exergetic evaluation was combined with the emission computation to ascertain the effects of operating variables like extraction pressure ratio, extracted mass rate, turbine inlet temperature (TIT), ambient relative humidity, and mass of injected water on the thermo-environmental performance of the gas turbine cycle. Investigation of the proposed gas turbine cycle revealed an exergetic output of 33%, compared to 29% for base case. Proposed modification in basic gas turbine shows a drastic reduction in cycle's exergy loss from 24% to 3% with a considerable decrease in the percentage of local irreversibility of the compressor from 5% to 3% along with a rise in combustion irreversibility from 19% to 21%. The environmental advantage of adding evaporative after cooling to gas turbine cycle along with inlet air cooling can be seen from the significant reduction of NOx from 40 g/kg of fuel to 1 × 10−9 g/kg of fuel with the moderate increase of CO concentration from 36 g/kg of fuel to 99 g/kg of fuel when the fuel–air equivalence ratio reduces from 1.0 to 0.3. Emission assessment further reveals that the increase in ambient relative humidity from 20% to 80% causes a considerable reduction in NOx concentration from 9.5 to 5.8 g/kg of fuel while showing a negligible raise in CO concentration from 4.4 to 5.0 g/kg of fuel.


  • Energy and exergy analyses of a solar powered multi-effect cooling cycle

    by Rajesh Kumar, Esmail M.A. Mokheimer, Abdul Khaliq

    International publishers of academic, scientific and professional journals since 1979.