Quantitative multivoxel proton MR spectroscopy for the identification of white matter abnormalities in mild traumatic brain injury: Comparison between regional and global analysis
- 13 March 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 50 (5) , 1424-1432
Abstract
Background: 3D brain proton MR spectroscopic imaging (1H MRSI) facilitates simultaneous metabolic profiling of multiple loci, at higher, sub‐1 cm3, spatial resolution than single‐voxel 1H MRS with the ability to separate tissue‐type partial volume contribution(s).Purpose: To determine if: 1) white matter (WM) damage in mild traumatic brain injury (mTBI) is homogeneously diffuse, or if specific regions are more affected; 2) partial‐volume‐corrected, structure‐specific 1H MRSI voxel averaging is sensitive to regional WM metabolic abnormalities.Study Type: Retrospective cross‐sectional cohort study.Population: Twenty‐seven subjects: 15 symptomatic mTBI patients, 12 matched controls.Field Strength/Sequence: 3T using 3D 1H MRSI over a 360‐cm3 volume of interest (VOI) centered over the corpus callosum, partitioned into 480 voxels, each 0.75 cm3.Assessment: N‐acetyl‐aspartate (NAA), creatine, choline, and myo‐inositol concentrations estimated in predominantly WM regions: body, genu, and splenium of the corpus callosum, corona radiata, frontal, and occipital WM.Statistical Tests: Analysis of covariance (ANCOVA) to compare patients with controls in terms of regional concentrations. The effect sizes (Cohen's d) of the mean differences were compared across regions and with previously published global data obtained with linear regression of the WM over the entire VOI in the same dataset.Results: Despite patients' global VOI WM NAA being significantly lower than the controls', no regional differences were observed for any metabolite. Regional NAA comparisons, however, were all unidirectional (patients' NAA concentrations < controls') within a narrow range: 0.3 ≤ Cohen's d ≤ 0.6.Data Conclusion: Since the patient group was symptomatic and exhibiting global WM NAA deficits, these findings suggest: 1) diffuse axonal mTBI damage; that is 2) below the 1H MRSI detection threshold in small regions. Therefore, larger, ie, more sensitive, single‐voxel 1H MRS, placed anywhere in WM regions, may be well suited for mTBI 1H MRS studies, given that these results are confirmed in other cohorts.Level of Evidence: 2Technical Efficacy: Stage 3J. Magn. Reson. Imaging 2019;50:1424–1432.Keywords
Funding Information
- National Institutes of Health (NS090417, NS097494, NS39135, MH108962, MH110418, P41EB017183)
This publication has 36 references indexed in Scilit:
- Neuroimaging Biomarkers in Mild Traumatic Brain Injury (mTBI)Neuropsychology Review, 2013
- Mild Traumatic Brain Injury and Diffuse Axonal Injury in SwineJournal of Neurotrauma, 2011
- Test‐retest reliability and reproducibility of short‐echo‐time spectroscopic imaging of human brain at 3TMagnetic Resonance in Medicine, 2011
- A Longitudinal Proton Magnetic Resonance Spectroscopy Study of Mild Traumatic Brain InjuryJournal of Neurotrauma, 2011
- Whole-Brain Proton MR Spectroscopic Imaging of Mild-to-Moderate Traumatic Brain Injury and Correlation with Neuropsychological DeficitsJournal of Neurotrauma, 2010
- Neurometabolite Concentrations in Gray and White Matter in Mild Traumatic Brain Injury: An 1 H–Magnetic Resonance Spectroscopy StudyJournal of Neurotrauma, 2009
- Mapping of brain metabolite distributions by volumetric proton MR spectroscopic imaging (MRSI)Magnetic Resonance in Medicine, 2008
- Age dependence of regional proton metabolites T2 relaxation times in the human brain at 3 TMagnetic Resonance in Medicine, 2008
- Assessment of mitochondrial impairment in traumatic brain injury using high-resolution proton magnetic resonance spectroscopyJournal of Neurosurgery, 2008
- Proton echo‐planar spectroscopic imaging of J‐coupled resonances in human brain at 3 and 4 TeslaMagnetic Resonance in Medicine, 2007