Abstract
Bushfire events have shown a strong interaction between the bushfire front and ambient winds leading to fire-enhanced wind action, which may cause premature damage to the steel cladding systems used as the critical external building envelope. Therefore, this thesis investigated the behaviour and strength of crest-fixed cold-formed steel (CFS) claddings under combined wind and bushfire actions. Comprehensive experimental and numerical studies of three CFS cladding systems were conducted under combined fire-enhanced wind action and elevated temperatures, and new design rules were developed. This research has thus enhanced the safety of CFS claddings in bushfires and overall bushfire resilience of buildings.