Evaluation of the physical and radiological properties of different Fricke gel formulations as water-equivalent materials and biological tissues
Authors:
- Ângela M. M. SantosÂSÂngela M. M. Santos
- Lucas F. AraújoLALucas F. Araújo
- Luíza R. CostaLCLuíza R. Costa
- Natália R. S. AraújoNANatália R. S. Araújo
- Rita C. O. SebastiãoRSRita C. O. Sebastião
- Lucas PaixãoLPLucas Paixão
- Ester M. R. AndradeEAEster M. R. Andrade
- Bruno M. MendesBMBruno M. Mendes
- Amir Z. MesquitaAMAmir Z. Mesquita
- Telma C. F. FonsecaTFTelma C. F. Fonseca
- 9 September 2026
- journal article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055010
Abstract
Fricke gel dosimeters, also known as hydrogels, have emerged as attractive tools in clinical dosimetry due to the stringent requirements of quality assurance protocols and radiation protection programs. The performance of these materials strongly depends on the characteristics of the polymeric matrices that constitute them. Their ability to mimic reference materials, such as water and biological tissue, has been widely investigated for applications as simulators in radiotherapy procedures. This study aims to evaluate the physical and radiological properties of Fricke gel formulations prepared with different polymeric matrices: porcine skin gelatin (GEL), sodium carboxymethylcellulose (CMC), guar gum (GGU), and poly(vinyl alcohol) (PVA). Key-parameters, including the linear and mass attenuation coefficients ( μ and μ / ρ ), the mass energy-absorption ( μ en / ρ ), the electronic stopping power (Stp e ), and the effective atomic number ( Z eff ), were determined using both experimental and computational methods. The physical investigations included the evaluation of thermal decomposition, determined by thermogravimetric analysis and kinetic analysis, incorporating isoconversional models based on multilayer perceptron (MLP) neural networks. The results obtained experimentally and through computational tools such as Phy-X, XCOM, TOPAS, EGSnrc, and ESTAR, for the different Fricke gel formulations, revealed that all gel formulations exhibit radiological parameters comparable to those of reference materials (water and biological tissue), in accordance with ICRU Report 44. Thermal analysis revealed distinct stability characteristics among the Fricke gel compositions. The GGU and PVA formulations exhibited greater thermal resistance compared with the GEL and CMC compositions. Kinetic analysis indicated that the average activation energy values for all formulations were below 40 kJ mol − 1 , suggesting that the thermal degradation processes initiate at relatively low temperatures. The application of MLP mathematical method proved valuable for accurately modeling the observed thermal kinetics. This study demonstrates that Fricke gel formulations (GEL, CMC, GGU, and PVA) effectively mimic the radiological response of biological tissue and water. Their performance in the field of radiotherapy is relevant for applications in three-dimensional dosimetry and radiological simulations due to their tissue-equivalent properties.Keywords
This publication has 50 references indexed in Scilit:
- Validation of the Tena pregnancy phantom and fetal dose assessment in proton scanning beam therapyPhysica Medica, 2026
- Impact of radiotherapy plan complexity on dosimetric measurement verification: A technical evaluation of two O-ring detector systemsPhysica Medica, 2025
- Modeling and validation of a system for measurement of linear attenuation coefficients of tissue substitutes for internal dosimetry phantoms using PHITS Monte Carlo codeApplied Radiation and Isotopes, 2025
- Feasibility of new polymeric matrices in the production of ferrous sulphate dosimetersApplied Radiation and Isotopes, 2024
- Characterization of Radiochromic Hydrogel Dosimeter-Ferrous Xylenol Orange Enhanced to Have a Higher Melting PointBrazilian Journal of Physics, 2024
- Multilayer perceptron network and Vyazovkin method applied to the non-isothermal kinetic study of the interaction between lumefantrine and molecularly imprinted polymerJournal of Thermal Analysis and Calorimetry, 2020
- Phy-X/ZeXTRa: a software for robust calculation of effective atomic numbers for photon, electron, proton, alpha particle, and carbon ion interactionsRadiation and Environmental Biophysics, 2020
- Combustion kinetics of wet-torrefied forest residues using the distributed activation energy model (DAEM)Applied Energy, 2017
- The isoconversional method for determination of energy of activation at constant heating ratesJournal of Thermal Analysis and Calorimetry, 1983
- Photon mass attenuation and energy-absorption coefficientsThe International Journal of Applied Radiation and Isotopes, 1982