Bruno Melo Mendes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bruno Melo Mendes has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Telma Cristina Ferreira Fonseca
Federal University of Minas Gerais
4 shared publications - Ester Maria Rodrigues de Andrade
Nuclear Technology Development Center, Belo Horizonte, Brazil
3 shared publications - Andréa Vidal Ferreira
Centro de Desenvolvimento da Tecnologia Nuclear
2 shared publications - Hirys Sales
Centro de Desenvolvimento da Tecnologia Nuclear
2 shared publications - Lucas Paixão
Federal University of Minas Gerais
2 shared publications - Amir Zacarias Mesquita
CDTN Nuclear Technology Development Center Belo Horizonte Brazil
1 shared publication
Latest Publications
- 9 September 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055010
Evaluation of the physical and radiological properties of different Fricke gel formulations as water-equivalent materials and biological tissues
Fricke gel dosimeters, also known as hydrogels, have emerged as attractive tools in clinical dosimetry due to the stringent requirements of quality assurance protocols and radiation protection programs. The performance of these materials strongly depends on the characteristics of the polymeric matrices that constitute them. Their ability to mimic reference materials, such as water and biological tissue, has been widely investigated for applications as simulators in radiotherapy procedures. This study aims to evaluate the physical and radiological properties of Fricke gel formulations prepared with different polymeric matrices: porcine skin gelatin (GEL), sodium carboxymethylcellulose (CMC), guar gum (GGU), and poly(vinyl alcohol) (PVA). Key-parameters, including the linear and mass attenuation coefficients ( μ and μ / ρ ), the mass energy-absorption ( μ en / ρ ), the electronic stopping power (Stp e ), and the effective atomic number ( Z eff ), were determined using both experimental and computational methods. The physical investigations included the evaluation of thermal decomposition, determined by thermogravimetric analysis and kinetic analysis, incorporating isoconversional models based on multilayer perceptron (MLP) neural networks. The results obtained experimentally and through computational tools such as Phy-X, XCOM, TOPAS, EGSnrc, and ESTAR, for the different Fricke gel formulations, revealed that all gel formulations exhibit radiological parameters comparable to those of reference materials (water and biological tissue), in accordance with ICRU Report 44. Thermal analysis revealed distinct stability characteristics among the Fricke gel compositions. The GGU and PVA formulations exhibited greater thermal resistance compared with the GEL and CMC compositions. Kinetic analysis indicated that the average activation energy values for all formulations were below 40 kJ mol − 1 , suggesting that the thermal degradation processes initiate at relatively low temperatures. The application of MLP mathematical method proved valuable for accurately modeling the observed thermal kinetics. This study demonstrates that Fricke gel formulations (GEL, CMC, GGU, and PVA) effectively mimic the radiological response of biological tissue and water. Their performance in the field of radiotherapy is relevant for applications in three-dimensional dosimetry and radiological simulations due to their tissue-equivalent properties.
- 9 September 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055010
Evaluation of the physical and radiological properties of different Fricke gel formulations as water-equivalent materials and biological tissues
Fricke gel dosimeters, also known as hydrogels, have emerged as attractive tools in clinical dosimetry due to the stringent requirements of quality assurance protocols and radiation protection programs. The performance of these materials strongly depends on the characteristics of the polymeric matrices that constitute them. Their ability to mimic reference materials, such as water and biological tissue, has been widely investigated for applications as simulators in radiotherapy procedures. This study aims to evaluate the physical and radiological properties of Fricke gel formulations prepared with different polymeric matrices: porcine skin gelatin (GEL), sodium carboxymethylcellulose (CMC), guar gum (GGU), and poly(vinyl alcohol) (PVA). Key-parameters, including the linear and mass attenuation coefficients ( μ and μ / ρ ), the mass energy-absorption ( μ en / ρ ), the electronic stopping power (Stp e ), and the effective atomic number ( Z eff ), were determined using both experimental and computational methods. The physical investigations included the evaluation of thermal decomposition, determined by thermogravimetric analysis and kinetic analysis, incorporating isoconversional models based on multilayer perceptron (MLP) neural networks. The results obtained experimentally and through computational tools such as Phy-X, XCOM, TOPAS, EGSnrc, and ESTAR, for the different Fricke gel formulations, revealed that all gel formulations exhibit radiological parameters comparable to those of reference materials (water and biological tissue), in accordance with ICRU Report 44. Thermal analysis revealed distinct stability characteristics among the Fricke gel compositions. The GGU and PVA formulations exhibited greater thermal resistance compared with the GEL and CMC compositions. Kinetic analysis indicated that the average activation energy values for all formulations were below 40 kJ mol − 1 , suggesting that the thermal degradation processes initiate at relatively low temperatures. The application of MLP mathematical method proved valuable for accurately modeling the observed thermal kinetics. This study demonstrates that Fricke gel formulations (GEL, CMC, GGU, and PVA) effectively mimic the radiological response of biological tissue and water. Their performance in the field of radiotherapy is relevant for applications in three-dimensional dosimetry and radiological simulations due to their tissue-equivalent properties.
- Open Access
- 16 June 2026
- Published by Elsevier in SSRN Electronic Journal
Estimated effective dose in a female anthropomorphic phantom (ICRP) from irradiation of topaz activated in a nuclear reactor
Purpose: To estimate the effective dose distribution resulting from the use of reactor-activated topaz gemstones as personal adornments and to evaluate their compliance with national and international radiological protection regulatory limits.Materials and Methods: Monte Carlo simulations were performed using the PHITS code and the female voxel anthropomorphic phantom ICRP-145. Six neutron-activated topaz samples from Rondônia, Brazil, were modeled considering their elemental composition and density. Gamma-ray spectra experimentally obtained after more than one year of decay were used together with nuclear decay data from ICRP Publication 107. Exposure scenarios simulated the use of earrings and necklaces under conservative and occasional-use conditions. Effective doses were compared with the limits established by ANSN Standard 3.01 and with international reference levels proposed by the IAEA SSG-36 and European Commission Radiation Protection 146.Results: Photon emissions from the radionuclides 46Sc and 54Mn were identified as the main contributors to dose. Nevertheless, all calculated values remained below the annual limit of 10 μSv year -1 established by ANSN 3.01. Under the conservative exposure scenario, annual effective doses ranged from 0.09 to 0.18 μSv year -1; conversely, under occasional-use conditions, all estimated doses remained below 0.02 μSv year -1.Conclusion: Activated topaz gemstones used as personal adornments do not represent a significant radiological risk under the investigated conditions. Although conservative scenarios exceeded the most restrictive international reference interval for consumer products, occasional-use conditions remained within internationally recommended levels.
- 16 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEstimated effective dose in a female anthropomorphic phantom (ICRP) from irradiation of topaz activated in a nuclear reactor
Purpose: To estimate the effective dose distribution resulting from the use of reactor-activated topaz gemstones as personal adornments and to evaluate their compliance with national and international radiological protection regulatory limits.Materials and Methods: Monte Carlo simulations were performed using the PHITS code and the female voxel anthropomorphic phantom ICRP-145. Six neutron-activated topaz samples from Rondônia, Brazil, were modeled considering their elemental composition and density. Gamma-ray spectra experimentally obtained after more than one year of decay were used together with nuclear decay data from ICRP Publication 107. Exposure scenarios simulated the use of earrings and necklaces under conservative and occasional-use conditions. Effective doses were compared with the limits established by ANSN Standard 3.01 and with international reference levels proposed by the IAEA SSG-36 and European Commission Radiation Protection 146.Results: Photon emissions from the radionuclides 46Sc and 54Mn were identified as the main contributors to dose. Nevertheless, all calculated values remained below the annual limit of 10 μSv year -1 established by ANSN 3.01. Under the conservative exposure scenario, annual effective doses ranged from 0.09 to 0.18 μSv year -1; conversely, under occasional-use conditions, all estimated doses remained below 0.02 μSv year -1.Conclusion: Activated topaz gemstones used as personal adornments do not represent a significant radiological risk under the investigated conditions. Although conservative scenarios exceeded the most restrictive international reference interval for consumer products, occasional-use conditions remained within internationally recommended levels.
- Open Access
- 6 June 2025
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 13 (2A (Suppl.) , e2843
Reference Male Phantom for Internal Dosimetry-RMPID: Physical model in 3D-printing for whole-body counter calibration
In vivo internal dosimetry can use a whole-body counter (WBC) to estimate radionuclides' incorporated activity (Bq) in internally contaminated individuals. The WBC must be calibrated to convert the count rate from the detector into activity incorporated in the person. Active physical phantoms could be used for the calibration procedure. Additive manufacturing allows the physical reproduction of ICRP computational models with good geometric fidelity. This study aims to develop imaging manipulation techniques to generate stereolithography (STL) parts for the 3D printing a male physical phantom based on the Adult Male Reference Computational Phantom (RCP_AM) model provided in the ICRP 110 publication. The Reference Male Phantom for Internal Dosimetry (RMPID) was developed based on the model provided by the ICRP in text file format containing the RCP_AM segmentation information. It was processed with an in-house C++ program that generated images in RAW format (Unprocessed images). The images were manipulated using freeware: ImageJ, MeshLab, FreeCAD, and Meshmixer. A set of 22 hollow portions, 44 pieces including the lids, which fit together, were obtained. The RMPID was printed in PLA (Polylactic Acid) on the Creality Ender 5 Plus 3D printer. The 3D-printed phantom parts passed leak tests, proving that imaging manipulation techniques resulted in well-sealed parts. That will allow the phantom to be safely filled with tissue-equivalent material containing a calibrated activity of the selected radionuclide. The design also makes the simulator easier to handle and to assemble during calibration routines.
- 6 June 2025
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 13 (2A (Suppl.) , e2843
Open AccessReference Male Phantom for Internal Dosimetry-RMPID: Physical model in 3D-printing for whole-body counter calibration
In vivo internal dosimetry can use a whole-body counter (WBC) to estimate radionuclides' incorporated activity (Bq) in internally contaminated individuals. The WBC must be calibrated to convert the count rate from the detector into activity incorporated in the person. Active physical phantoms could be used for the calibration procedure. Additive manufacturing allows the physical reproduction of ICRP computational models with good geometric fidelity. This study aims to develop imaging manipulation techniques to generate stereolithography (STL) parts for the 3D printing a male physical phantom based on the Adult Male Reference Computational Phantom (RCP_AM) model provided in the ICRP 110 publication. The Reference Male Phantom for Internal Dosimetry (RMPID) was developed based on the model provided by the ICRP in text file format containing the RCP_AM segmentation information. It was processed with an in-house C++ program that generated images in RAW format (Unprocessed images). The images were manipulated using freeware: ImageJ, MeshLab, FreeCAD, and Meshmixer. A set of 22 hollow portions, 44 pieces including the lids, which fit together, were obtained. The RMPID was printed in PLA (Polylactic Acid) on the Creality Ender 5 Plus 3D printer. The 3D-printed phantom parts passed leak tests, proving that imaging manipulation techniques resulted in well-sealed parts. That will allow the phantom to be safely filled with tissue-equivalent material containing a calibrated activity of the selected radionuclide. The design also makes the simulator easier to handle and to assemble during calibration routines.
- 21 January 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 230
Monte Carlo study of reduction of inherent Pb-210 decay chain emissions from shielding in whole body counters
- 21 January 2025
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 230
Monte Carlo study of reduction of inherent Pb-210 decay chain emissions from shielding in whole body counters
- 14 May 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (4) , 045015
RFPID: development and 3D-printing of a female physical phantom for whole-body counter
Whole-body counters (WBC) are used in internal dosimetry for in vivo monitoring in radiation protection. The calibration processes of a WBC set-up include the measurement of a physical phantom filled with a certificate radioactive source that usually is referred to a standard set of individuals determined by the International Commission on Radiological Protection (ICRP). The aim of this study was to develop an anthropomorphic and anthropometric female physical phantom for the calibration of the WBC systems. The reference female computational phantom of the ICRP, now called RFPID (Reference Female Phantom for Internal Dosimetry) was printed using PLA filament and with an empty interior. The goal is to use the RFPID to reduce the uncertainties associated with in vivo monitoring system. The images which generated the phantom were manipulated using ImageJ®, Amide®, GIMP® and the 3D Slicer® software. RFPID was split into several parts and printed using a 3D printer in order to print the whole-body phantom. The newly printed physical phantom RFPID was successfully fabricated, and it is suitable to mimic human tissue, anatomically similar to a human body i.e., size, shape, material composition, and density.
- 14 May 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (4) , 045015
RFPID: development and 3D-printing of a female physical phantom for whole-body counter
Whole-body counters (WBC) are used in internal dosimetry for in vivo monitoring in radiation protection. The calibration processes of a WBC set-up include the measurement of a physical phantom filled with a certificate radioactive source that usually is referred to a standard set of individuals determined by the International Commission on Radiological Protection (ICRP). The aim of this study was to develop an anthropomorphic and anthropometric female physical phantom for the calibration of the WBC systems. The reference female computational phantom of the ICRP, now called RFPID (Reference Female Phantom for Internal Dosimetry) was printed using PLA filament and with an empty interior. The goal is to use the RFPID to reduce the uncertainties associated with in vivo monitoring system. The images which generated the phantom were manipulated using ImageJ®, Amide®, GIMP® and the 3D Slicer® software. RFPID was split into several parts and printed using a 3D printer in order to print the whole-body phantom. The newly printed physical phantom RFPID was successfully fabricated, and it is suitable to mimic human tissue, anatomically similar to a human body i.e., size, shape, material composition, and density.
- Open Access
- 10 January 2024
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 12 (1) , e2360
Development of alternative methodology for normalization of the small animals PET scanner of LIM/CDTN
Normalization is a step taken to correct variations in count rates between detection channels of small animals PET scanners. In general, in laboratory practice, normalization is performed using a commercial source of germanium 68. Given the half-life of the Ge-68 isotope, the normalization source must be replaced every two years at most, which generates a significant spent for the Laboratory. The objective of this work was to develop and test an alternative rechargeable source to be used on normalization routine. The results indicated that the rechargeable source (18F-FDG) can be used to replace the commercial source.
- 10 January 2024
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 12 (1) , e2360
Open AccessDevelopment of alternative methodology for normalization of the small animals PET scanner of LIM/CDTN
Normalization is a step taken to correct variations in count rates between detection channels of small animals PET scanners. In general, in laboratory practice, normalization is performed using a commercial source of germanium 68. Given the half-life of the Ge-68 isotope, the normalization source must be replaced every two years at most, which generates a significant spent for the Laboratory. The objective of this work was to develop and test an alternative rechargeable source to be used on normalization routine. The results indicated that the rechargeable source (18F-FDG) can be used to replace the commercial source.
- Open Access
- 20 December 2022
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 10 (4) , 1-12
18F-FES radiation dosimetry preliminary estimates for preclinical studies based on voxelized phantom
Small animals, such as mice, are used in radiopharmaceutical biodistribution studies and innumerous others preclinical investigations involving ionizing radiation. Longitudinal preclinical studies with five or more image procedures, involving radiopharmaceuticals injection and/or X-radiation, are not uncommon. However, a suitable dosimetric evaluation is not always available and, sometimes, absorbed doses in animal organs or tissues and their influence in experimental results were not appropriately taken into account. Accurate calculation of absorbed doses in mice organs are needed to evaluate potential radiobiological effects that may interfere with in vivo experiments. In this work, we perform a preliminary 16α-[18F]-fluoro-17β-estradiol (18F-FES) radiation dosimetry estimates for female mice. The obtained animal dosimetric results can be useful for evaluating animal doses during the design of longitudinal preclinical studies.
- 20 December 2022
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 10 (4) , 1-12
Open Access18F-FES radiation dosimetry preliminary estimates for preclinical studies based on voxelized phantom
Small animals, such as mice, are used in radiopharmaceutical biodistribution studies and innumerous others preclinical investigations involving ionizing radiation. Longitudinal preclinical studies with five or more image procedures, involving radiopharmaceuticals injection and/or X-radiation, are not uncommon. However, a suitable dosimetric evaluation is not always available and, sometimes, absorbed doses in animal organs or tissues and their influence in experimental results were not appropriately taken into account. Accurate calculation of absorbed doses in mice organs are needed to evaluate potential radiobiological effects that may interfere with in vivo experiments. In this work, we perform a preliminary 16α-[18F]-fluoro-17β-estradiol (18F-FES) radiation dosimetry estimates for female mice. The obtained animal dosimetric results can be useful for evaluating animal doses during the design of longitudinal preclinical studies.
- Open Access
- 5 July 2022
- Published by Revista Brasileira de Fisica Medica in Revista Brasileira de Física Médica
- Vol. 16, 567
Comparação entre diferentes metodologias para a determinação da atividade mínima detectável dos sistemas de dosimetria interna in vivo
A atividade mínima detectável (AMD) representa o valor mínimo de atividade que é detectada em um sistema de monotoração. Existem diversas metodologias que podem ser utilizadas para calcular a AMD, no entanto os resultados para cada uma destas podem ser divergentes. Laboratórios de dosimetria interna in vivo devem dispor deste parâmetro para cada tipo de geometria de contagem, bem como, para cada tipo de radionuclídeo de interesse, visando a otimização do processo de monitoração interna. O objetivo deste trabalho foi comparar três tipos de metodologias de cálculo utilizadas na determinação da AMD com os resultados obtidos experimentalmente. As metodologias de cálculo utilizadas foram as sugeridas por Currie (1968), a publicada em Health Physics Society N13.30 (1996) e a ISO 11929 (2018). A monitoração de um phantom de cabeça contendo na região correspondente ao cérebro 18F-FDG foi realizada para a obtenção da AMD experimental. Os resultados obtidos para os valores de AMDs utilizando as três diferentes metodologias apresentaram diferenças de acordo com as faixas de atividades analisadas. As incertezas do fator de calibração e Background do sistema são os principais parâmetros entre as três metodologias de cálculo que influenciaram nos resultados obtidos.
- 5 July 2022
- Published by Revista Brasileira de Fisica Medica in Revista Brasileira de Física Médica
- Vol. 16, 567
Open AccessComparação entre diferentes metodologias para a determinação da atividade mínima detectável dos sistemas de dosimetria interna in vivo
A atividade mínima detectável (AMD) representa o valor mínimo de atividade que é detectada em um sistema de monotoração. Existem diversas metodologias que podem ser utilizadas para calcular a AMD, no entanto os resultados para cada uma destas podem ser divergentes. Laboratórios de dosimetria interna in vivo devem dispor deste parâmetro para cada tipo de geometria de contagem, bem como, para cada tipo de radionuclídeo de interesse, visando a otimização do processo de monitoração interna. O objetivo deste trabalho foi comparar três tipos de metodologias de cálculo utilizadas na determinação da AMD com os resultados obtidos experimentalmente. As metodologias de cálculo utilizadas foram as sugeridas por Currie (1968), a publicada em Health Physics Society N13.30 (1996) e a ISO 11929 (2018). A monitoração de um phantom de cabeça contendo na região correspondente ao cérebro 18F-FDG foi realizada para a obtenção da AMD experimental. Os resultados obtidos para os valores de AMDs utilizando as três diferentes metodologias apresentaram diferenças de acordo com as faixas de atividades analisadas. As incertezas do fator de calibração e Background do sistema são os principais parâmetros entre as três metodologias de cálculo que influenciaram nos resultados obtidos.