Counting Efficiencies Determined by Monte Carlo Methods for In Vivo Measurement of 131I Activity in Thyroid
Authors:
- 26 March 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 117 (4) , 388-395
Abstract
The counting efficiencies obtained using a physical neck phantom are typically used in the measurement of 131I activity in the thyroid. It is well known, however, that the geometrical discrepancies between the physical neck phantom and the anatomy of the subject can significantly influence the counting efficiencies. Thus, it is necessary to consider the anatomical characteristics of individuals if we need to accurately determine the activity of 131I in the thyroid. This study aims to produce individualized counting efficiencies for thyroid measurement, considering the age, sex, and overlying tissue thickness of the subject being measured by Monte Carlo simulation. Simulations were performed using a series of computational human phantoms of different ages and sexes. The difference in counting efficiencies, depending on the age and sex of the phantom, were found to range from −26 to 3% for the phantoms and monitoring systems considered in the present study. The overlying tissue thickness of the computational phantoms was also modified to find the relationship between the counting ratio of the 80.2 and 364 keV gammas from 131I and the overlying tissue thickness. The equations for estimating the overlying tissue thickness of a subject were then derived from the relationships between counting ratios and overlying tissue thickness. Finally, in the present study, a set of equations representing the variation in counting efficiencies for the 364 keV peak as a function of the overlying tissue thickness were derived, which can be used to determine individualized counting efficiencies for the subject being measured. These individualized counting efficiencies considering the overlying tissue thickness given a subject’s age and sex can provide accurate estimates of 131I activity for internal dosimetry.Keywords
This publication has 12 references indexed in Scilit:
- NUMERICAL SIMULATION OF DIRECT MEASUREMENT TO DETERMINE THYROID131I CONTENT OF TWO TEPCO WORKERS CONSIDERING INDIVIDUAL TISSUE THICKNESSRadiation Protection Dosimetry, 2016
- NUMERICAL ASSESSMENT OF131I DEPOSITED IN THYROID FOR NON-STANDARD SITUATIONSRadiation Protection Dosimetry, 2015
- Estimation of internal exposure of the thyroid to 131I on the basis of 134Cs accumulated in the body among evacuees of the Fukushima Daiichi Nuclear Power Station accidentEnvironment International, 2013
- Thyroid Consequences of the Fukushima Nuclear Reactor AccidentEuropean Thyroid Journal, 2012
- Performance assessment and uncertainty evaluation of a portable NaI-based detection system used for thyroid monitoringRadiation Protection Dosimetry, 2012
- The UF family of reference hybrid phantoms for computational radiation dosimetryPhysics in Medicine & Biology, 2009
- Calibration of a phoswich type partial body counter by Monte Carlo simulation of low-energy photon transportRadiation Protection Dosimetry, 2007
- Individual monitoring for internal exposure in Europe and the integration of dosimetric dataRadiation Protection Dosimetry, 2004
- Thyroid cancer after ChernobylNature, 1992
- Thyroid cancer after ChernobylNature, 1992