Wi-Ho Ha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wi-Ho Ha has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Jaeryong Yoo
6 shared publicationsSeokwon Yoon
6 shared publicationsSunhoo Park
National Radiation Emergency Center, Korea Institute of Radiological and Medical Sciences, Seoul, Republic of Korea
6 shared publicationsYoung-Woo Jin
Korea Institute of Radiological and Medical Sciences
6 shared publicationsSeung-Sook Lee
National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea
5 shared publicationsYoung Woo Jin
Laboratory of Health Physics, National Radiation Emergency Medical Center, Korea Institute of Radiological and Medical Sciences, Seoul, Korea
4 shared publications
Latest Publications
- Open Access
- 30 June 2020
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 45 (2) , 88-94
Optimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR
- 30 June 2020
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 45 (2) , 88-94
Open AccessOptimal Monitoring Intervals and MDA Requirements for Routine Individual Monitoring of Occupational Intakes Based on the ICRP OIR
- 26 March 2019
- Published by Wolters Kluwer Health in Health Physics
- Vol. 117 (4) , 388-395
Counting Efficiencies Determined by Monte Carlo Methods for In Vivo Measurement of 131I Activity in Thyroid
The counting efficiencies obtained using a physical neck phantom are typically used in the measurement of 131I activity in the thyroid. It is well known, however, that the geometrical discrepancies between the physical neck phantom and the anatomy of the subject can significantly influence the counting efficiencies. Thus, it is necessary to consider the anatomical characteristics of individuals if we need to accurately determine the activity of 131I in the thyroid. This study aims to produce individualized counting efficiencies for thyroid measurement, considering the age, sex, and overlying tissue thickness of the subject being measured by Monte Carlo simulation. Simulations were performed using a series of computational human phantoms of different ages and sexes. The difference in counting efficiencies, depending on the age and sex of the phantom, were found to range from −26 to 3% for the phantoms and monitoring systems considered in the present study. The overlying tissue thickness of the computational phantoms was also modified to find the relationship between the counting ratio of the 80.2 and 364 keV gammas from 131I and the overlying tissue thickness. The equations for estimating the overlying tissue thickness of a subject were then derived from the relationships between counting ratios and overlying tissue thickness. Finally, in the present study, a set of equations representing the variation in counting efficiencies for the 364 keV peak as a function of the overlying tissue thickness were derived, which can be used to determine individualized counting efficiencies for the subject being measured. These individualized counting efficiencies considering the overlying tissue thickness given a subject’s age and sex can provide accurate estimates of 131I activity for internal dosimetry.
- 26 March 2019
- Published by Wolters Kluwer Health in Health Physics
- Vol. 117 (4) , 388-395
Counting Efficiencies Determined by Monte Carlo Methods for In Vivo Measurement of 131I Activity in Thyroid
The counting efficiencies obtained using a physical neck phantom are typically used in the measurement of 131I activity in the thyroid. It is well known, however, that the geometrical discrepancies between the physical neck phantom and the anatomy of the subject can significantly influence the counting efficiencies. Thus, it is necessary to consider the anatomical characteristics of individuals if we need to accurately determine the activity of 131I in the thyroid. This study aims to produce individualized counting efficiencies for thyroid measurement, considering the age, sex, and overlying tissue thickness of the subject being measured by Monte Carlo simulation. Simulations were performed using a series of computational human phantoms of different ages and sexes. The difference in counting efficiencies, depending on the age and sex of the phantom, were found to range from −26 to 3% for the phantoms and monitoring systems considered in the present study. The overlying tissue thickness of the computational phantoms was also modified to find the relationship between the counting ratio of the 80.2 and 364 keV gammas from 131I and the overlying tissue thickness. The equations for estimating the overlying tissue thickness of a subject were then derived from the relationships between counting ratios and overlying tissue thickness. Finally, in the present study, a set of equations representing the variation in counting efficiencies for the 364 keV peak as a function of the overlying tissue thickness were derived, which can be used to determine individualized counting efficiencies for the subject being measured. These individualized counting efficiencies considering the overlying tissue thickness given a subject’s age and sex can provide accurate estimates of 131I activity for internal dosimetry.
- 1 March 2018
- Published by Wolters Kluwer Health in Health Physics
- Vol. 114 (3) , 282-287
Measurement and Simulation of the Counting Efficiency of a Whole-body Counter Using a BOMAB Phantom Inserted with Rod Sources Containing Mixed Radionuclides
The examination of internal contamination is important for providing an adequate medical response during a radiological emergency. A whole-body counting system can assess gamma-emitting radionuclides in a human body when monitoring internal contamination. It is necessary to calibrate whole-body counting systems by using a calibration phantom, such as a Bottle Manikin Absorption phantom, to properly assess internal contamination. However, the total weight of the Bottle Manikin Absorber phantom is high, and there can be leakage of radioactive sources, which are disadvantages of using such a phantom. This study proposes a calibration phantom that is designed to overcome these disadvantages. The proposed phantom consists of rod sources that are inserted in each part of the phantom. The counting efficiency of the rod-source-inserted calibration phantom was acquired using a Monte Carlo simulation method, but the results were evaluated by comparing the experimental efficiencies with those of a conventional Bottle Manikin Absorption phantom by using two commercial whole-body counting systems (stand-up type and bed type). The efficiency curve of the rod-source-inserted phantom matched well that of the conventional calibration phantom. The relative deviation between the efficiencies of the conventional Bottle Manikin Absorption phantom and the proposed calibration phantom in both whole-body counting systems was less than 11%, and the total weight of the phantom was also reduced. These results suggest that the proposed phantom can be manipulated more easily and replace the conventional Bottle Manikin Absorption calibration phantom for these two types of whole-body counting systems.
- 1 March 2018
- Published by Wolters Kluwer Health in Health Physics
- Vol. 114 (3) , 282-287
Measurement and Simulation of the Counting Efficiency of a Whole-body Counter Using a BOMAB Phantom Inserted with Rod Sources Containing Mixed Radionuclides
The examination of internal contamination is important for providing an adequate medical response during a radiological emergency. A whole-body counting system can assess gamma-emitting radionuclides in a human body when monitoring internal contamination. It is necessary to calibrate whole-body counting systems by using a calibration phantom, such as a Bottle Manikin Absorption phantom, to properly assess internal contamination. However, the total weight of the Bottle Manikin Absorber phantom is high, and there can be leakage of radioactive sources, which are disadvantages of using such a phantom. This study proposes a calibration phantom that is designed to overcome these disadvantages. The proposed phantom consists of rod sources that are inserted in each part of the phantom. The counting efficiency of the rod-source-inserted calibration phantom was acquired using a Monte Carlo simulation method, but the results were evaluated by comparing the experimental efficiencies with those of a conventional Bottle Manikin Absorption phantom by using two commercial whole-body counting systems (stand-up type and bed type). The efficiency curve of the rod-source-inserted phantom matched well that of the conventional calibration phantom. The relative deviation between the efficiencies of the conventional Bottle Manikin Absorption phantom and the proposed calibration phantom in both whole-body counting systems was less than 11%, and the total weight of the phantom was also reduced. These results suggest that the proposed phantom can be manipulated more easily and replace the conventional Bottle Manikin Absorption calibration phantom for these two types of whole-body counting systems.
- 1 February 2018
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 72 (3) , 444-448
A Method for Using a Radiophotoluminescence Glass Dosimeter in Accurate Tissue Dosimetry
In the field of radiation dosimetry, a radiophotoluminescence glass dosimeter (RPLGD) has become one of widely used dosimeters owing to its better properties compared to other conventionally used dosimeters. However, it is questionable if its absorbed dose can represent dose received by water or body tissue because the RPLGD has significantly different physical and radiological properties from those of water, which is commonly accepted as standard material in clinical dosimetry. In the present paper, the feasibility of using the RPLGD in tissue dosimetry was investigated by means of Monte-Carlo simulations, which were validated with experimental data obtained under well-defined conditions. As a result, it was quantitatively demonstrated that RPLGD dose and water dose generally do not agree each other, while such differences can be compensated by employing a correction factor. In this study, we present a method combining experimental and computational dosimetry techniques that could reduce uncertainty in dosimetry.
- 1 February 2018
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 72 (3) , 444-448
A Method for Using a Radiophotoluminescence Glass Dosimeter in Accurate Tissue Dosimetry
In the field of radiation dosimetry, a radiophotoluminescence glass dosimeter (RPLGD) has become one of widely used dosimeters owing to its better properties compared to other conventionally used dosimeters. However, it is questionable if its absorbed dose can represent dose received by water or body tissue because the RPLGD has significantly different physical and radiological properties from those of water, which is commonly accepted as standard material in clinical dosimetry. In the present paper, the feasibility of using the RPLGD in tissue dosimetry was investigated by means of Monte-Carlo simulations, which were validated with experimental data obtained under well-defined conditions. As a result, it was quantitatively demonstrated that RPLGD dose and water dose generally do not agree each other, while such differences can be compensated by employing a correction factor. In this study, we present a method combining experimental and computational dosimetry techniques that could reduce uncertainty in dosimetry.
- Open Access
- 28 July 2017
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 58 (5) , 755-760
Development of a minipig physical phantom from CT data
Quantification of pathological progression of radiation-induced injury is essential in development of treatment methods, and a proper animal model is necessary for relevant radiological and medical studies. A minipig is a current animal model selected because of its similarities to humans in anatomy and pathology. In the present study, a minipig physical phantom was developed using computed tomography (CT) data. For dosimetry purposes, the minipig physical phantom was constructed on a slice-by-slice basis, with an array of holes to accommodate dosimeters. The phantom is constituted of three major organs, i.e. bone, lung, and remaining soft tissue, and the organs are clearly distinguishable on each 20-mm-thick axial slice. The quality of the tissue-equivalent (TE) substitutes was analyzed in terms of the atomic compositions and Hounsfield units (HUs). The density (in g/cm3) and effective atomic number of TE substitutes for the bone, lung, and soft tissue are 1.4 and 7.9, 0.5 and 10.0, and 1.0 and 5.9, respectively. Although the TE substitutes have slightly different physical properties, we think the phantom is acceptable because the HU values of the TE substitutes lie in the HU range of real tissues.
- 28 July 2017
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 58 (5) , 755-760
Open AccessDevelopment of a minipig physical phantom from CT data
Quantification of pathological progression of radiation-induced injury is essential in development of treatment methods, and a proper animal model is necessary for relevant radiological and medical studies. A minipig is a current animal model selected because of its similarities to humans in anatomy and pathology. In the present study, a minipig physical phantom was developed using computed tomography (CT) data. For dosimetry purposes, the minipig physical phantom was constructed on a slice-by-slice basis, with an array of holes to accommodate dosimeters. The phantom is constituted of three major organs, i.e. bone, lung, and remaining soft tissue, and the organs are clearly distinguishable on each 20-mm-thick axial slice. The quality of the tissue-equivalent (TE) substitutes was analyzed in terms of the atomic compositions and Hounsfield units (HUs). The density (in g/cm3) and effective atomic number of TE substitutes for the bone, lung, and soft tissue are 1.4 and 7.9, 0.5 and 10.0, and 1.0 and 5.9, respectively. Although the TE substitutes have slightly different physical properties, we think the phantom is acceptable because the HU values of the TE substitutes lie in the HU range of real tissues.
- 6 July 2017
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 37 (3) , 635-641
Estimation of counting efficiencies of a portable NaI detector using Monte Carlo simulation for thyroid measurement following nuclear accidents
Radioiodine can be released in nuclear accidents and can cause internal contamination of the thyroid gland in members of the public. For population monitoring in radiation emergencies, measurement of counting efficiency is very important to accurately determine thyroid activity. Here, we estimate the counting efficiencies of a portable NaI detector using Monte Carlo simulations. Two different types of neck phantoms and a 7.62 cm long by 7.62 cm diameter NaI detector were modeled and the counting efficiencies were calculated depending on the thyroid size and distance from the neck phantom to the detector. We found that distance is a more important parameter than thyroid size. The optimal distance of the NaI detector from the neck surface was determined to be greater than 12 cm, beyond which the counting efficiency was not affected by thyroid size.
- 6 July 2017
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 37 (3) , 635-641
Estimation of counting efficiencies of a portable NaI detector using Monte Carlo simulation for thyroid measurement following nuclear accidents
Radioiodine can be released in nuclear accidents and can cause internal contamination of the thyroid gland in members of the public. For population monitoring in radiation emergencies, measurement of counting efficiency is very important to accurately determine thyroid activity. Here, we estimate the counting efficiencies of a portable NaI detector using Monte Carlo simulations. Two different types of neck phantoms and a 7.62 cm long by 7.62 cm diameter NaI detector were modeled and the counting efficiencies were calculated depending on the thyroid size and distance from the neck phantom to the detector. We found that distance is a more important parameter than thyroid size. The optimal distance of the NaI detector from the neck surface was determined to be greater than 12 cm, beyond which the counting efficiency was not affected by thyroid size.
- Open Access
- 30 June 2017
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 42 (2) , 83-90
Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays
- 30 June 2017
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 42 (2) , 83-90
Open AccessAssessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays
- Open Access
- 31 December 2016
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 41 (4) , 333-338
Optimization of In-vivo Monitoring Program for Radiation Emergency Response
- 31 December 2016
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 41 (4) , 333-338
Open AccessOptimization of In-vivo Monitoring Program for Radiation Emergency Response
- Open Access
- 30 September 2016
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 41 (3) , 274-281
An Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom
- 30 September 2016
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 41 (3) , 274-281
Open AccessAn Intercomparison of Counting Efficiency and the Performance of Two Whole-Body Counters According to the Type of Phantom
- Open Access
- 30 September 2016
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 41 (3) , 301-309
An Off-site Screening Process for the Public in Radiation Emergencies and Disasters
- 30 September 2016
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 41 (3) , 301-309
Open AccessAn Off-site Screening Process for the Public in Radiation Emergencies and Disasters