In Vitro Assessment of Retention and Fit Precision in Cast, 3D-Printed Cobalt-Chromium and Polyether Ether Ketone Clasps Subjected to Fatigue Cycling
Open Access
Abstract
Objectives: This study aimed to compare the retention and fit precision of removable partial denture circumferential clasps fabricated from cast cobalt–chromium, 3D-printed cobalt–chromium, and polyether ether ketone. Methods: A maxillary right first premolar abutment was prepared. Eighty circumferential clasps were allocated into three material groups: cast Co–Cr (n = 20), 3D-printed Co–Cr (n = 20), and PEEK (n = 40). The terminal third of metal retentive clasps was designed to engage 0.25 mm and 0.50 mm undercuts. PEEK clasps were fabricated with two designs: partial (two-thirds) and full-arm undercut engagement. Each group was examined for retentive forces after 1440 cycles (simulating 1 year). Initial and final retentive forces were recorded. Clasp deformation was assessed by measuring inter-arm distance before and after cycling using digital photography and ImageJ software. Results: All clasp groups demonstrated a statistically significant reduction in retention after 1440 cycles (p < 0.05). At both undercut depths, cast and 3D-printed Co–Cr clasps exhibited significantly higher retentive forces than PEEK (p < 0.001). Within the PEEK group, full-arm engagement showed significantly higher retention than partial engagement at the 0.25 mm undercut (p < 0.001), whereas no significant difference was observed between designs at the 0.50 mm undercut (p = 0.406). Fit precision revealed a significant increase in inter-arm distance after cycling (p < 0.05). PEEK clasps exhibited significantly smaller dimensional changes than Co–Cr clasps (p < 0.02). Conclusions: Clasp material, undercut depth, and design significantly influenced retention and fit precision. Co–Cr clasps maintained higher retentive forces, whereas PEEK clasps demonstrated reduced deformation after cycling.Keywords
This publication has 46 references indexed in Scilit:
- Retention and fatigue performance of modified polyetheretherketone clasps for removable prosthesisJournal of the Mechanical Behavior of Biomedical Materials, 2024
- Fatigue behavior of removable partial denture cast and laser‐sintered cobalt‐chromium (CoCr) and polyetheretherketone (PEEK) clasp materialsClinical and Experimental Dental Research, 2022
- Deformation and retentive force following in vitro cyclic fatigue of cobalt-chrome and aryl ketone polymer (AKP) claspsDental Materials, 2019
- Fatigue strength of Co–Cr–Mo alloy clasps prepared by selective laser meltingJournal of the Mechanical Behavior of Biomedical Materials, 2016
- Applications of polyetheretherketone (PEEK) in oral implantology and prosthodonticsJournal of Prosthodontic Research, 2016
- Effect of acetyl resin retentive arms on the retentive force of circumferential clasps: An in vitro studyJournal of Prosthodontic Research, 2012
- Retentive forces and fatigue resistance of thermoplastic resin claspsDental Materials, 2012
- Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failuresClinical Oral Investigations, 2000
- A comparison of various removable partial denture clasp materials and fabrication procedure for placing clasps on canine and premolar teethThe Journal of Prosthetic Dentistry, 1993
- The effect of reducing the number of clasps on removable partial denture retentionThe Journal of Prosthetic Dentistry, 1992