Neda Al-Kaisy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Neda Al-Kaisy has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bruska Azhdar
Nanotechnology Research Laboratory, Department of Physics, College of Science, University of Sulaimani, Sulaimani 46001, Iraq
1 shared publication - Didar Anwar
University of Sulaimani, P. O. Box: 46001 Sulaimani-Iraq, Sulaimani, Kurdistan, 46001, IRAQ
1 shared publication - Hawa M Fathi
Department of Prosthodontic, School of Dental Science, Newcastle University, Newcastle upon Tyne, UK
1 shared publication - Jwan Fateh Abdulkareem
Department of Prosthodontics, College of Dentistry, University of Sulaimani, Sulaymaniyah 46001, Iraq
1 shared publication - Lazyan Raouf
Department of Prosthodontic, College of Dentistry, University of Sulaimani, Sulaimani 46001, Iraq
1 shared publication - Mohammed Mudher Mohammed
Department of Prosthodontics, College of Dentistry, University of Sulaimani, Sulaymaniyah 46001, Iraq
1 shared publication
Latest Publications
- Open Access
In Vitro Assessment of Retention and Fit Precision in Cast, 3D-Printed Cobalt-Chromium and Polyether Ether Ketone Clasps Subjected to Fatigue Cycling
Objectives: This study aimed to compare the retention and fit precision of removable partial denture circumferential clasps fabricated from cast cobalt–chromium, 3D-printed cobalt–chromium, and polyether ether ketone. Methods: A maxillary right first premolar abutment was prepared. Eighty circumferential clasps were allocated into three material groups: cast Co–Cr (n = 20), 3D-printed Co–Cr (n = 20), and PEEK (n = 40). The terminal third of metal retentive clasps was designed to engage 0.25 mm and 0.50 mm undercuts. PEEK clasps were fabricated with two designs: partial (two-thirds) and full-arm undercut engagement. Each group was examined for retentive forces after 1440 cycles (simulating 1 year). Initial and final retentive forces were recorded. Clasp deformation was assessed by measuring inter-arm distance before and after cycling using digital photography and ImageJ software. Results: All clasp groups demonstrated a statistically significant reduction in retention after 1440 cycles (p < 0.05). At both undercut depths, cast and 3D-printed Co–Cr clasps exhibited significantly higher retentive forces than PEEK (p < 0.001). Within the PEEK group, full-arm engagement showed significantly higher retention than partial engagement at the 0.25 mm undercut (p < 0.001), whereas no significant difference was observed between designs at the 0.50 mm undercut (p = 0.406). Fit precision revealed a significant increase in inter-arm distance after cycling (p < 0.05). PEEK clasps exhibited significantly smaller dimensional changes than Co–Cr clasps (p < 0.02). Conclusions: Clasp material, undercut depth, and design significantly influenced retention and fit precision. Co–Cr clasps maintained higher retentive forces, whereas PEEK clasps demonstrated reduced deformation after cycling.
Open AccessIn Vitro Assessment of Retention and Fit Precision in Cast, 3D-Printed Cobalt-Chromium and Polyether Ether Ketone Clasps Subjected to Fatigue Cycling
Objectives: This study aimed to compare the retention and fit precision of removable partial denture circumferential clasps fabricated from cast cobalt–chromium, 3D-printed cobalt–chromium, and polyether ether ketone. Methods: A maxillary right first premolar abutment was prepared. Eighty circumferential clasps were allocated into three material groups: cast Co–Cr (n = 20), 3D-printed Co–Cr (n = 20), and PEEK (n = 40). The terminal third of metal retentive clasps was designed to engage 0.25 mm and 0.50 mm undercuts. PEEK clasps were fabricated with two designs: partial (two-thirds) and full-arm undercut engagement. Each group was examined for retentive forces after 1440 cycles (simulating 1 year). Initial and final retentive forces were recorded. Clasp deformation was assessed by measuring inter-arm distance before and after cycling using digital photography and ImageJ software. Results: All clasp groups demonstrated a statistically significant reduction in retention after 1440 cycles (p < 0.05). At both undercut depths, cast and 3D-printed Co–Cr clasps exhibited significantly higher retentive forces than PEEK (p < 0.001). Within the PEEK group, full-arm engagement showed significantly higher retention than partial engagement at the 0.25 mm undercut (p < 0.001), whereas no significant difference was observed between designs at the 0.50 mm undercut (p = 0.406). Fit precision revealed a significant increase in inter-arm distance after cycling (p < 0.05). PEEK clasps exhibited significantly smaller dimensional changes than Co–Cr clasps (p < 0.02). Conclusions: Clasp material, undercut depth, and design significantly influenced retention and fit precision. Co–Cr clasps maintained higher retentive forces, whereas PEEK clasps demonstrated reduced deformation after cycling.
- Open Access
- 1 April 2025
- Published by IOP Publishing in Materials Research Express
- Vol. 12 (4) , 045402
Influence of activated bentonite nanoclay/TiO2 on antibiofilm and mechanical properties of PMMA denture base nanocomposite
Objectives. This study aimed to evaluate the effects of bentonite nanoclay (B) and titanium-activated bentonite nanocomposite (BT) on reducing Candida albicans adherence to heat-polymerized acrylic denture base resin and to assess the mechanical properties of the modified acrylic, focusing on surface hardness and flexural strength. Methods. A total of 182 heat-polymerized acrylic resin specimens were fabricated, including a control group and 12 study groups (n = 7). The study groups incorporated bentonite nanoclay (B) or titanium-bentonite nanocomposite (BT) at six concentrations: 0.5, 1, 1.5, 2, 2.5, and 3 wt%. Antibiofilm activity was evaluated using a crystal violet (CV) staining assay. Flexural strength and surface hardness were measured via a three-point bending and Shore D microhardness test. Nanocomposite characterization was performed using XRD, FTIR, SEM, EDS analysis, and (AFM). Antibiofilm data were analyzed using the Kruskal–Wallis test and mechanical data with one-way ANOVA (α = 0.05). Results. All groups exhibited significantly better antibiofilm activity than the control (4.07 ± 0.11), with BT 1.5% (1.41 ± 0.27) and B 1.5% (1.81 ± 0.40) being the most effective. Flexural strength was significantly lower in all groups compared to the control (90.57 ± 3.78), decreasing with increased B and BT concentrations, but remained above the minimum 65 MPa for denture bases. BT samples at 2.5% and 3% showed non-significant improvements in hardness compared with the control. Conclusions. At 1.5%, bentonite significantly enhanced antibiofilm activity without greatly reducing hardness, whereas Ti-bentonite offered superior performance in both antifungal and mechanical properties, making it a promising material for denture bases. Clinical significance. Incorporating Ti-bentonite nanocomposites into acrylic denture bases may reduce Candida albicans. adhesion while preserving adequate mechanical properties. This reduction in fungal colonization on the denture surface can potentially enhance denture hygiene, prevent oral inflammation, and reduce the risk of denture-related infections such as candidiasis and denture stomatitis.
- 1 April 2025
- Published by IOP Publishing in Materials Research Express
- Vol. 12 (4) , 045402
Open AccessInfluence of activated bentonite nanoclay/TiO2 on antibiofilm and mechanical properties of PMMA denture base nanocomposite
Objectives. This study aimed to evaluate the effects of bentonite nanoclay (B) and titanium-activated bentonite nanocomposite (BT) on reducing Candida albicans adherence to heat-polymerized acrylic denture base resin and to assess the mechanical properties of the modified acrylic, focusing on surface hardness and flexural strength. Methods. A total of 182 heat-polymerized acrylic resin specimens were fabricated, including a control group and 12 study groups (n = 7). The study groups incorporated bentonite nanoclay (B) or titanium-bentonite nanocomposite (BT) at six concentrations: 0.5, 1, 1.5, 2, 2.5, and 3 wt%. Antibiofilm activity was evaluated using a crystal violet (CV) staining assay. Flexural strength and surface hardness were measured via a three-point bending and Shore D microhardness test. Nanocomposite characterization was performed using XRD, FTIR, SEM, EDS analysis, and (AFM). Antibiofilm data were analyzed using the Kruskal–Wallis test and mechanical data with one-way ANOVA (α = 0.05). Results. All groups exhibited significantly better antibiofilm activity than the control (4.07 ± 0.11), with BT 1.5% (1.41 ± 0.27) and B 1.5% (1.81 ± 0.40) being the most effective. Flexural strength was significantly lower in all groups compared to the control (90.57 ± 3.78), decreasing with increased B and BT concentrations, but remained above the minimum 65 MPa for denture bases. BT samples at 2.5% and 3% showed non-significant improvements in hardness compared with the control. Conclusions. At 1.5%, bentonite significantly enhanced antibiofilm activity without greatly reducing hardness, whereas Ti-bentonite offered superior performance in both antifungal and mechanical properties, making it a promising material for denture bases. Clinical significance. Incorporating Ti-bentonite nanocomposites into acrylic denture bases may reduce Candida albicans. adhesion while preserving adequate mechanical properties. This reduction in fungal colonization on the denture surface can potentially enhance denture hygiene, prevent oral inflammation, and reduce the risk of denture-related infections such as candidiasis and denture stomatitis.
- Open Access
- 15 March 2025
- Published by Journal of Baghdad College of Dentistry in Journal of Baghdad College of Dentistry
- Vol. 37 (1) , 37-48
Exploring palatal dimensions in a sample of kurdish edentulous population: influence of age, gender and duration of edentulism
Background: Complete denture construction requires accurate measurements of the edentulous palate to ensure optimal fit and function. This study aimed to evaluate palatal dimensions in a sample of Kurdish edentulous population and determine the effects of age, gender and duration of edentulism on these measurements. Materials and Methods: Maxillary stone models were obtained from 51 edentulous participants, comprising 26 women and 25 men aged 40–75 years. Palatal linear measurements, including length, width and height, along with ratios involving palatal, rugae, and incisive papilla area size, were evaluated and correlated with age, sex and the edentulous duration. Digital caliber and ImageJ software were employed for accurate linear measurements and size evaluations. Results: A significant sex-related impact was found on the palatal size in middle palate width and posterior height, with men exhibiting higher values than women (45.29 and 12.47 mm vs. 43.2 and 10.78 mm). Palatal ratios remained consistent across both sexes. Notably, an increase in palatal height was observed with longer durations of edentulism (H1–H3 increased from 6.68, 10.42 and 10.07 mm, respectively, to 8.30, 12.72 and 12.87 mm, respectively). Conclusions: Men demonstrated significantly higher values in middle palatal width, posterior height and palate area size than women. This study underscores the influence of age and edentulous duration on palatal dimensions, providing valuable data to guide clinicians in their dental rehabilitation planning. Palatal height indices were identified as a valuable tool for exploring denture construction.
- 15 March 2025
- Published by Journal of Baghdad College of Dentistry in Journal of Baghdad College of Dentistry
- Vol. 37 (1) , 37-48
Open AccessExploring palatal dimensions in a sample of kurdish edentulous population: influence of age, gender and duration of edentulism
Background: Complete denture construction requires accurate measurements of the edentulous palate to ensure optimal fit and function. This study aimed to evaluate palatal dimensions in a sample of Kurdish edentulous population and determine the effects of age, gender and duration of edentulism on these measurements. Materials and Methods: Maxillary stone models were obtained from 51 edentulous participants, comprising 26 women and 25 men aged 40–75 years. Palatal linear measurements, including length, width and height, along with ratios involving palatal, rugae, and incisive papilla area size, were evaluated and correlated with age, sex and the edentulous duration. Digital caliber and ImageJ software were employed for accurate linear measurements and size evaluations. Results: A significant sex-related impact was found on the palatal size in middle palate width and posterior height, with men exhibiting higher values than women (45.29 and 12.47 mm vs. 43.2 and 10.78 mm). Palatal ratios remained consistent across both sexes. Notably, an increase in palatal height was observed with longer durations of edentulism (H1–H3 increased from 6.68, 10.42 and 10.07 mm, respectively, to 8.30, 12.72 and 12.87 mm, respectively). Conclusions: Men demonstrated significantly higher values in middle palatal width, posterior height and palate area size than women. This study underscores the influence of age and edentulous duration on palatal dimensions, providing valuable data to guide clinicians in their dental rehabilitation planning. Palatal height indices were identified as a valuable tool for exploring denture construction.