Enhancing the Measurement Sensitivity and Repeatability of Electrolyte-Insulator-Semiconductor Capacitor Sensor With Impedance Conversion
- 23 February 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
Abstract
The measured performance of the electrolyte-insulator-semiconductor capacitor (EISCAP) is related not only to the device structure and technology, but also to the measurement methods. For the conventional amplitude measurement method, since the capacitance of EISCAP is very small, the measurement procedure is easily affected by the fluctuation of reference electrode and solution impedance, which leads to low sensitivity and poor repeatability. In this study, a measurement method with impedance conversion is proposed for enhancing the measured sensitivity and repeatability of the EISCAP. Different from the conventional measurement method, an impedance conversion stage is inserted in front of the transimpedance amplifier in this approach; thus, the fluctuation of impedance of solution and reference electrode is suppressed, and the measurement repeatability is improved. At the same time, the capacitance of the sensor has been significantly amplified, so that the sensitivity can be improved. Under the condition of 2 kHz, compared with the traditional measurement method, the measurement sensitivity and repeatability with the proposed approach were improved by 13.81% and 63.64%, respectively.Keywords
Funding Information
- National Natural Science Foundation of China (62271389)
- Key Scientific Research Program of Shaanxi Provincial Department of Education (22JY058)
- Innovation Fund Project in Xi’an University of Posts and Telecommunications (CXJJZL2021002)
This publication has 20 references indexed in Scilit:
- A high-Q resonance-mode measurement of EIS capacitive sensor by elimination of series resistanceSensors and Actuators B: Chemical, 2017
- Label‐Free Sensing of Biomolecules with Field‐Effect Devices for Clinical ApplicationsElectroanalysis, 2014
- Potentiometric estimation of blood analytes—triglycerides and urea: Comparison with clinical data and estimation of urea in milk using an electrolyte–insulator–semiconductor–capacitor (EISCAP)Sensors and Actuators B: Chemical, 2011
- Novel applications of silicon and porous silicon based EISCAP biosensorsPhysica Status Solidi (a), 2009
- Comparison of a potentiometric and a micromechanical triglyceride biosensorBiosensors and Bioelectronics, 2009
- A wireless LC chemical sensor based on a high quality factor EIS capacitorSensors and Actuators B: Chemical, 2007
- Field-effect sensors with charged macromolecules: Characterisation by capacitance–voltage, constant-capacitance, impedance spectroscopy and atomic-force microscopy methodsBiosensors and Bioelectronics, 2007
- Anodically oxidized porous silicon as a substrate for EIS sensorsMaterials Science and Engineering: C, 2006
- Development of biosensors based on an electrolyte isolator semiconductor (EIS) -capacitor structure and their application for process monitoring. Part I. Development of the biosensors and their characterizationAnalytica Chimica Acta, 1995
- Field effect potentiometric sensorsAnalytical Chemistry, 1977