Dong Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dong Chen has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Xingyuan Tong
School of Electronics Engineering, Xian University of Posts and Telecommunications, Xian, China
3 shared publications - Zheng Hao
School of Electronics Engineering, Xian University of Posts and Telecommunications, Xian, China
3 shared publications - Xueliang Li
School of Mechanical and Electrical Engineering, Zhoukou Normal University, Zhoukou 466001, China
2 shared publications - Gaoxu Dong
School of Electronics Engineering, Xian University of Posts and Telecommunications, Xian, China
1 shared publication - Gui-Fang Li
School of Electronics and Information, Northwestern Polytechnical University, Xian, China
1 shared publication Jintao Liang
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi, China
1 shared publication
Latest Publications
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
An Enhanced Measurement Method With Voltage–Frequency–Voltage Conversion of EISCAP Sensor
Conventional amplitude measurement of electrolyte-insulator-semiconductor capacitor (EISCAP) sensor is convenient, but susceptible to noise interference which can deteriorate the measurement accuracy. In this study, a new amplitude- measurement method based on voltage-frequency-voltage (V/F/V) conversion is proposed, which is composed of impedance conversion, hysteresis comparison and frequency-to-voltage conversion. The impedance conversion technique increases the equivalent capacitance of EISCAP; thus the measurement sensitivity is improved obviously. The change of EISCAP output voltage is converted into the frequency variation of a periodic pulse signal by the hysteresis comparator. Compared to amplitude of a signal, its frequency is less susceptible to circuit noise, so that the anti-noise ability of the measurement system is enhanced. Voltage output is more convenient and flexible, at the end of the detection circuit, the frequency-to-voltage conversion is performed. With this proposed amplitude- measurement method, the relative error of measurement is decreased from 2.2643% to 0.0045%. After using impedance converter, the detection sensitivity is increased by 88.66% from 0.0344/pH to 0.0649/pH at fixed bias voltage mode, and by 64.94% from 39.53 mV/pH to 65.20 mV/pH at fixed amplitude mode, respectively. In addition, the linearity was also improved by 7.77%, and the repeatability standard deviation was decreased by 20% from 0.0045 to 0.0036.
- 21 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
An Enhanced Measurement Method With Voltage–Frequency–Voltage Conversion of EISCAP Sensor
Conventional amplitude measurement of electrolyte-insulator-semiconductor capacitor (EISCAP) sensor is convenient, but susceptible to noise interference which can deteriorate the measurement accuracy. In this study, a new amplitude- measurement method based on voltage-frequency-voltage (V/F/V) conversion is proposed, which is composed of impedance conversion, hysteresis comparison and frequency-to-voltage conversion. The impedance conversion technique increases the equivalent capacitance of EISCAP; thus the measurement sensitivity is improved obviously. The change of EISCAP output voltage is converted into the frequency variation of a periodic pulse signal by the hysteresis comparator. Compared to amplitude of a signal, its frequency is less susceptible to circuit noise, so that the anti-noise ability of the measurement system is enhanced. Voltage output is more convenient and flexible, at the end of the detection circuit, the frequency-to-voltage conversion is performed. With this proposed amplitude- measurement method, the relative error of measurement is decreased from 2.2643% to 0.0045%. After using impedance converter, the detection sensitivity is increased by 88.66% from 0.0344/pH to 0.0649/pH at fixed bias voltage mode, and by 64.94% from 39.53 mV/pH to 65.20 mV/pH at fixed amplitude mode, respectively. In addition, the linearity was also improved by 7.77%, and the repeatability standard deviation was decreased by 20% from 0.0045 to 0.0036.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (10) , 10538-10545
Trench Bottom Optical Isolation for Suppressing Lateral Diffusion of Photocarriers in LAPS
Lateral diffusion of photocarriers in substrate causes the cross-talk in light-addressable potentiometric sensor (LAPS), which degrades the performance of LAPS. Surface optical isolation is a useful method to suppress the cross-talk in LAPS of backside irradiation manner, but the remarkable reduction of detection signal is a defect. In this study, a method of trench bottom optical isolation is developed. Main idea of this method is using the trench structure to narrow the diffusion scope of photocarriers, then irradiating the trench bottom by isolation light to locally suppress cross-talk. According to experimental analysis, when using 400 μm thick substrate, 240 μm deep trench and 100 mA drive current of isolation laser, the suppressing ability of trench bottom optical isolation is 1.38 times as strong as surface optical isolation, and 3.14 times as strong as having no isolation. Besides, the detection signal intensity of trench bottom optical isolation is 1.4 times as great as surface optical isolation. Thus, the method of trench bottom optical isolation can effectively suppress the cross-talk and reduce the loss of detection signal.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (10) , 10538-10545
Trench Bottom Optical Isolation for Suppressing Lateral Diffusion of Photocarriers in LAPS
Lateral diffusion of photocarriers in substrate causes the cross-talk in light-addressable potentiometric sensor (LAPS), which degrades the performance of LAPS. Surface optical isolation is a useful method to suppress the cross-talk in LAPS of backside irradiation manner, but the remarkable reduction of detection signal is a defect. In this study, a method of trench bottom optical isolation is developed. Main idea of this method is using the trench structure to narrow the diffusion scope of photocarriers, then irradiating the trench bottom by isolation light to locally suppress cross-talk. According to experimental analysis, when using 400 μm thick substrate, 240 μm deep trench and 100 mA drive current of isolation laser, the suppressing ability of trench bottom optical isolation is 1.38 times as strong as surface optical isolation, and 3.14 times as strong as having no isolation. Besides, the detection signal intensity of trench bottom optical isolation is 1.4 times as great as surface optical isolation. Thus, the method of trench bottom optical isolation can effectively suppress the cross-talk and reduce the loss of detection signal.
- 23 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
Enhancing the Measurement Sensitivity and Repeatability of Electrolyte-Insulator-Semiconductor Capacitor Sensor With Impedance Conversion
The measured performance of the electrolyte-insulator-semiconductor capacitor (EISCAP) is related not only to the device structure and technology, but also to the measurement methods. For the conventional amplitude measurement method, since the capacitance of EISCAP is very small, the measurement procedure is easily affected by the fluctuation of reference electrode and solution impedance, which leads to low sensitivity and poor repeatability. In this study, a measurement method with impedance conversion is proposed for enhancing the measured sensitivity and repeatability of the EISCAP. Different from the conventional measurement method, an impedance conversion stage is inserted in front of the transimpedance amplifier in this approach; thus, the fluctuation of impedance of solution and reference electrode is suppressed, and the measurement repeatability is improved. At the same time, the capacitance of the sensor has been significantly amplified, so that the sensitivity can be improved. Under the condition of 2 kHz, compared with the traditional measurement method, the measurement sensitivity and repeatability with the proposed approach were improved by 13.81% and 63.64%, respectively.
- 23 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-7
Enhancing the Measurement Sensitivity and Repeatability of Electrolyte-Insulator-Semiconductor Capacitor Sensor With Impedance Conversion
The measured performance of the electrolyte-insulator-semiconductor capacitor (EISCAP) is related not only to the device structure and technology, but also to the measurement methods. For the conventional amplitude measurement method, since the capacitance of EISCAP is very small, the measurement procedure is easily affected by the fluctuation of reference electrode and solution impedance, which leads to low sensitivity and poor repeatability. In this study, a measurement method with impedance conversion is proposed for enhancing the measured sensitivity and repeatability of the EISCAP. Different from the conventional measurement method, an impedance conversion stage is inserted in front of the transimpedance amplifier in this approach; thus, the fluctuation of impedance of solution and reference electrode is suppressed, and the measurement repeatability is improved. At the same time, the capacitance of the sensor has been significantly amplified, so that the sensitivity can be improved. Under the condition of 2 kHz, compared with the traditional measurement method, the measurement sensitivity and repeatability with the proposed approach were improved by 13.81% and 63.64%, respectively.