No radiographic difference between patient‐specific guiding and conventional Oxford UKA surgery
Authors:
- 26 January 2014
- journal article
- knee
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 23 (5) , 1324-1329
Abstract
Purpose: Implant position is an important factor in unicompartmental knee arthroplasty (UKA) surgery. Results on conventional UKA alignment are commonly described in literature. Patient‐specific guiding (PSG) is a new technique for positioning the Oxford UKA. Our hypothesis is that PSG improves component position without affecting the HKA angle.Methods: This prospective study compares the results of our first thirty cases of cementless Oxford UKA using PSG with thirty cases using conventional outlining. Baseline characteristics for both groups were identical. Details on handling of the guide, estimated blood loss and operation time were recorded. Postoperative screened radiographs and standing long‐leg radiographs of both groups were compared.Results: Median AP position of the femoral component was 3 degrees varus (−5 to 9) using PSG versus 2 degrees varus (−10 to 8) for the conventional group. For the femoral flexion, this was 9 degrees flexion (0–16) using PSG versus 12 degrees flexion (0–20). The tibial median AP position was 1 degree varus (−3 to 7) using PSG versus 2 degrees varus (−5 to 10). The median tibial posterior slope was 5 degrees (1–10) using PSG versus 5 degrees (0–12). All guides aligned well. No conversion to conventional outlining was performed, and no significant changes had to be made to the original approved plan. Operation time, estimated blood loss and postoperative haemoglobin drop were not significantly different between both groups.Discussion: Implant position was not different between both groups, even in the early phase of the learning curve. Perioperative results were not different between both groups.Level of evidence: III.Keywords
This publication has 10 references indexed in Scilit:
- Preliminary experience with the patient-specific templating total knee arthroplastyActa Orthopaedica, 2012
- Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplastyThe Knee, 2011
- Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty: A comparison with a conventional instrumented techniqueThe Knee, 2010
- Shortterm results of the Oxford phase 3 unicompartmental knee arthroplasty for medial arthritisActa Orthopaedica et Traumatologica Turcica, 2010
- Correlation of positioning and clinical results in Oxford UKAInternational Orthopaedics, 2009
- Analysis of Oxford medial unicompartmental knee replacement using the minimally invasive technique in patients aged 60 and above: an independent prospective seriesKnee Surgery, Sports Traumatology, Arthroscopy, 2007
- The Oxford phase III unicompartmental knee replacement in patients less than 60 years of ageKnee Surgery, Sports Traumatology, Arthroscopy, 2006
- Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacementThe Journal of Bone and Joint Surgery. British volume, 2006
- Unicompartmental knee prosthesis implantation with a non‐image‐based navigation system: rationale, technique, case‐control comparative study with a conventional instrumented implantationKnee Surgery, Sports Traumatology, Arthroscopy, 2002
- Accuracy of implantation of a unicompartmental total knee arthroplasty with 2 different instrumentationsThe Journal of Arthroplasty, 2002