Dosimetric accuracy of three dose calculation algorithms for radiation therapy of in situ non-small cell lung carcinoma
Open Access
- 14 March 2022
- journal article
- research article
- Published by VM Media Group sp. z o.o in Reports of Practical Oncology and Radiotherapy
- Vol. 27 (1) , 86-96
Abstract
Background: Study determines differences in calculated dose distributions for non-small cell lung carcinoma (NSCLC) patients. NSCLC cases were investigated, being the most common lung cancer treated by radiotherapy in our clinical practice. Materials and methods: A retrospective study of 15 NSCLC patient dose distributions originally calculated using standard superposition (SS) and recalculated using collapsed cone (CC) and Monte Carlo (MC) based algorithm expressed as dose to medium in medium (MCDm) and dose to water in medium (MCDw,) was performed so that prescribed dose covers at least 99% of the gross target volume (GTV). Statistical analysis was performed for differences of conformity index (CI), heterogeneity index (HI), gradient index (GI), dose delivered to 2% of the volume (D2%), mean dose (Dmean) and percentage of volumes covered by prescribed dose (V70Gy). For organs at risk (OARs), Dmean and percentage of volume receiving 20 Gy and 5Gy (V20Gy, V5Gy) were analysed. Results: Statistically significant difference for GTVs was observed between MCDw and SS algorithm in mean dose only. For planning target volumes (PTVs), statistically significant differences were observed in prescribed dose coverage for CC, MCDm and MCDw. The differences in mean CI value for the CC algorithm and mean HI value for MCDm and MCDw were statistically significant. There is a statistically significant difference in the number of MUs for MCDm and MCDw compared to SS. Conclusion: All investigated algorithms succeed in managing the restrictive conditions of the clinical goals. This study shows the drawbacks of the CC algorithm compared to other algorithms used. Background: Study determines differences in calculated dose distributions for non-small cell lung carcinoma (NSCLC) patients. NSCLC cases were investigated, being the most common lung cancer treated by radiotherapy in our clinical practice. Materials and methods: A retrospective study of 15 NSCLC patient dose distributions originally calculated using standard superposition (SS) and recalculated using collapsed cone (CC) and Monte Carlo (MC) based algorithm expressed as dose to medium in medium (MCDm) and dose to water in medium (MCDw,) was performed so that prescribed dose covers at least 99% of the gross target volume (GTV). Statistical analysis was performed for differences of conformity index (CI), heterogeneity index (HI), gradient index (GI), dose delivered to 2% of the volume (D2%), mean dose (Dmean) and percentage of volumes covered by prescribed dose (V70Gy). For organs at risk (OARs), Dmean and percentage of volume receiving 20 Gy and 5Gy (V20Gy, V5Gy) were analysed. Results: Statistically significant difference for GTVs was observed between MCDw and SS algorithm in mean dose only. For planning target volumes (PTVs), statistically significant differences were observed in prescribed dose coverage for CC, MCDm and MCDw. The differences in mean CI value for the CC algorithm and mean HI value for MCDm and MCDw were statistically significant. There is a statistically significant difference in the number of MUs for MCDm and MCDw compared to SS. Conclusion: All investigated algorithms succeed in managing the restrictive conditions of the clinical goals. This study shows the drawbacks of the CC algorithm compared to other algorithms used.Keywords
This publication has 31 references indexed in Scilit:
- Dosimetric Verification Using Monte Carlo Calculations for Tissue Heterogeneity-Corrected Conformal Treatment Plans Following RTOG 0813 Dosimetric Criteria for Lung Cancer Stereotactic Body RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Evaluation of heterogeneity dose distributions for Stereotactic Radiotherapy (SRT): comparison of commercially available Monte Carlo dose calculation with other algorithmsRadiation Oncology, 2012
- Higher Biologically Effective Dose of Radiotherapy Is Associated With Improved Outcomes for Locally Advanced Non–Small Cell Lung Carcinoma Treated With Chemoradiation: An Analysis of the Radiation Therapy Oncology GroupInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Dose specification for radiation therapy: dose to water or dose to medium?Physics in Medicine & Biology, 2011
- Dose to medium versus dose to water as an estimator of dose to sensitive skeletal tissuePhysics in Medicine & Biology, 2010
- Primary Analysis of the Phase II Component of a Phase I/II Dose Intensification Study Using Three-Dimensional Conformal Radiation Therapy and Concurrent Chemotherapy for Patients With Inoperable Non–Small-Cell Lung Cancer: RTOG 0117Journal of Clinical Oncology, 2010
- Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): An Introduction to the Scientific IssuesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Radiation Dose–Volume Effects in the LungInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Monte Carlo- versus pencil-beam-/collapsed-cone-dose calculation in a heterogeneous multi-layer phantomPhysics in Medicine & Biology, 2005
- A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell densityPhysics in Medicine & Biology, 1993