Slaven Jurković

Slaven Jurković

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Slaven Jurković has a total of 89 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of Weighting Factors on Dual-Energy Computed Tomography Image Quality in Non-Contrast Head Examinations: Phantom and Patient Study

    by Doris Šegota Ritoša, Doris Dodig, Slavica Kovačić, Nina Bartolović, Ivan Brumini, Petra Valković Zujić, Slaven Jurković, Damir Miletić

    Background: This study aims to evaluate the impact of various weighting factors (WFs) on the quality of weighted average (WA) dual-energy computed tomography (DECT) non-contrast brain images and to determine the optimal WF value. Because they simulate standard CT images, 0.4-WA reconstructions are routinely used. Methods: In the initial phase of the research, quantitative and qualitative analyses of WA DECT images of an anthropomorphic head phantom, utilizing WFs ranging from 0 to 1 in 0.1 increments, were conducted. Based on the phantom study findings, WFs of 0.4, 0.6, and 0.8 were chosen for patient analyses, which were identically carried out on 85 patients who underwent non-contrast head DECT. Three radiologists performed subjective phantom and patient analyses. Results: Quantitative phantom image analysis revealed the best gray-to-white matter contrast-to-noise ratio (CNR) at the highest WFs and minimal noise artifacts at the lowest WF values. However, the WA reconstructions were deemed non-diagnostic by all three readers. Two readers found 0.6-WA patient reconstructions significantly superior to 0.4-WA images (p < 0.001), while reader 1 found them to be equally good (p = 0.871). All readers agreed that 0.8-WA images exhibited the lowest image quality. Conclusions: In conclusion, 0.6-WA reconstructions demonstrated superior image quality over 0.4-WA and are recommended for routine non-contrast brain DECT.


  • Open Access

    Automated Vertebral Bone Quality Determination from T1-Weighted Lumbar Spine MRI Data Using a Hybrid Convolutional Neural Network–Transformer Neural Network

    by Kristian Stojšić, Dina Miletić Rigo, Slaven Jurković

    Vertebral bone quality (VBQ) is a promising new method that can improve screening for osteoporosis. The drawback of the current method is that it requires manual determination of the regions of interest (ROIs) of vertebrae and cerebrospinal fluid (CSF) by a radiologist. In this work, an automatic method for determining the VBQ is proposed, in which the ROIs are obtained using a trained neural network model. A large, publicly available dataset of sagittal lumbar spine MRI images with ground truth segmentations was used to train a BRAU-Net++ hybrid CNN–transformer neural network. The performance of the trained model was evaluated using the dice similarity coefficient (DSC), accuracy, precision, recall and intersection-over-union (IoU) metrics. The trained model performed similarly to state-of-the-art lumbar spine segmentation models, with an average DSC value of 0.914 ± 0.007 for the vertebrae and 0.902 for the spinal canal. Four different methods of VBQ determination with automatic segmentation are presented and compared with one-way ANOVA. These methods use different algorithms for CSF extraction from the segmentation of the spinal canal using T1- and T2-weighted image data and applying erosion to the vertebral ROI to avoid a sharp change in SI at the edge of the vertebral body.


  • Characterization of myocardial perfusion imaging systems - an extension of quality metrics

    by Dea Dundara Debeljuh, Roberta Matheoud, Orazio Zoccarato, Ivan Pribanić, Marco Brambilla, Slaven Jurković


  • Open Access

    Evaluation of Single-Photon Emission Computed Tomography Myocardial Perfusion Detection Capability through Physical Descriptors

    by Dea Dundara Debeljuh, Roberta Matheoud, Ivan Pribanić, Marco Brambilla, Slaven Jurković

    A comprehensive validation of data acquired by different myocardial perfusion imaging (MPI) systems was performed to evaluate contrast, self-attenuation properties, and perfusion detection capability. An anthropomorphic phantom with a myocardial insert and perfusion defect was used to simulate 99mTc-tetrofosmin distribution. Different MPI systems were evaluated: a SPECT system with iterative reconstruction algorithms and resolution recovery (IRR) with/without scatter correction (SPECT-IRR-SC and SPECT-IRR), and a cardio-centric IQ SPECT/CT system with IRR, with/without scatter and attenuation corrections (IQ-IRR-SC-AC and IQ-IRR). The image quality was assessed through physical descriptors: the contrast between the left ventricular (LV) wall and LV inner chamber (CLV/LVIC), intrinsic contrast (IC), and net contrast (NC). CLV/LVIC was found to be superior for IQ-IRR-SC-AC. The IC results showed non-uniformity of the signal intensity in the LV wall for the SPECT systems. The lowest IC values were obtained for IQ-IRR-SC-AC, except for septal position, where an underestimation of the signal intensity was revealed. The NC was found to be the highest for IQ-IRR-SC-AC and SPECT-IRR-SC. Additionally, for IQ-IRR-SC-AC, the NC increased in posterior and septal positions compared to IQ-IRR, enabling better perfusion detection capability over short-axis images. IQ-IRR showed performances comparable to SPECT-IRR. The characterization and evaluation perfusion detection capability of the MPI systems enabled the investigation of the systems’ performance and limitations.

  • Open Access

    Review of: "Analysis of Dosimetric Parameters of Linear Accelerator"

    by Slaven Jurković

    The manuscript is dedicated to the measurements, determination, and analysis of the dosimetric parameters of high-energy X-ray and electron beams used in radiation oncology. The concepts described and the devices used are very well known and extensiv...

  • Open Access

    On dosimetric characteristics of detectors for relative dosimetry in small fields: a multicenter experimental study

    by Božidar Casar, Ignasi Mendez, Eduard Gershkevitsh, Sonja Wegener, David Jaffray, Robert Heaton, Csilla Pesznyak, Gabor Stelczer, Wojciech Bulski, Krzysztof Chełminski, et al.

    Objective . In this multicentric collaborative study, we aimed to verify whether the selected radiation detectors satisfy the requirements of TRS-483 Code of Practice for relative small field dosimetry in megavoltage photon beams used in radiotherapy, by investigating four dosimetric characteristics. Furthermore, we intended to analyze and complement the recommendations given in TRS-483. Approach . Short-term stability, dose linearity, dose-rate dependence, and leakage were determined for 17 models of detectors considered suitable for small field dosimetry. Altogether, 47 detectors were used in this study across ten institutions. Photon beams with 6 and 10 MV, with and without flattening filters, generated by Elekta Versa HD TM or Varian TrueBeam TM linear accelerators, were used. Main results . The tolerance level of 0.1% for stability was fulfilled by 70% of the data points. For the determination of dose linearity, two methods were considered. Results from the use of a stricter method show that the guideline of 0.1% for dose linearity is not attainable for most of the detectors used in the study. Following the second approach (squared Pearson’s correlation coefficient r 2 ), it was found that 100% of the data fulfill the criteria r 2 > 0.999 (0.1% guideline for tolerance). Less than 50% of all data points satisfied the published tolerance of 0.1% for dose-rate dependence. Almost all data points (98.2%) satisfied the 0.1% criterion for leakage. Significance . For short-term stability (repeatability), it was found that the 0.1% guideline could not be met. Therefore, a less rigorous criterion of 0.25% is proposed. For dose linearity, our recommendation is to adopt a simple and clear methodology and to define an achievable tolerance based on the experimental data. For dose-rate dependence, a realistic criterion of 1% is proposed instead of the present 0.1%. Agreement was found with published guidelines for background signal (leakage).


  • Reduction of SPECT acquisition time using deep learning: A phantom study

    by Ivan Pribanić, Srđan Daniel Simić, Nikola Tanković, Dea Dundara Debeljuh, Slaven Jurković


  • Open Access

    Dosimetric accuracy of three dose calculation algorithms for radiation therapy of in situ non-small cell lung carcinoma

    by Manda Švabić Kolacio, David Rajlić, Milan Radojčić, Ðeni Smilović Radojčić, Nevena Obajdin, Dea Dundara Debeljuh, Slaven Jurković

    Background: Study determines differences in calculated dose distributions for non-small cell lung carcinoma (NSCLC) patients. NSCLC cases were investigated, being the most common lung cancer treated by radiotherapy in our clinical practice. Materials and methods: A retrospective study of 15 NSCLC patient dose distributions originally calculated using standard superposition (SS) and recalculated using collapsed cone (CC) and Monte Carlo (MC) based algorithm expressed as dose to medium in medium (MCDm) and dose to water in medium (MCDw,) was performed so that prescribed dose covers at least 99% of the gross target volume (GTV). Statistical analysis was performed for differences of conformity index (CI), heterogeneity index (HI), gradient index (GI), dose delivered to 2% of the volume (D2%), mean dose (Dmean) and percentage of volumes covered by prescribed dose (V70Gy). For organs at risk (OARs), Dmean and percentage of volume receiving 20 Gy and 5Gy (V20Gy, V5Gy) were analysed. Results: Statistically significant difference for GTVs was observed between MCDw and SS algorithm in mean dose only. For planning target volumes (PTVs), statistically significant differences were observed in prescribed dose coverage for CC, MCDm and MCDw. The differences in mean CI value for the CC algorithm and mean HI value for MCDm and MCDw were statistically significant. There is a statistically significant difference in the number of MUs for MCDm and MCDw compared to SS. Conclusion: All investigated algorithms succeed in managing the restrictive conditions of the clinical goals. This study shows the drawbacks of the CC algorithm compared to other algorithms used. Background: Study determines differences in calculated dose distributions for non-small cell lung carcinoma (NSCLC) patients. NSCLC cases were investigated, being the most common lung cancer treated by radiotherapy in our clinical practice. Materials and methods: A retrospective study of 15 NSCLC patient dose distributions originally calculated using standard superposition (SS) and recalculated using collapsed cone (CC) and Monte Carlo (MC) based algorithm expressed as dose to medium in medium (MCDm) and dose to water in medium (MCDw,) was performed so that prescribed dose covers at least 99% of the gross target volume (GTV). Statistical analysis was performed for differences of conformity index (CI), heterogeneity index (HI), gradient index (GI), dose delivered to 2% of the volume (D2%), mean dose (Dmean) and percentage of volumes covered by prescribed dose (V70Gy). For organs at risk (OARs), Dmean and percentage of volume receiving 20 Gy and 5Gy (V20Gy, V5Gy) were analysed. Results: Statistically significant difference for GTVs was observed between MCDw and SS algorithm in mean dose only. For planning target volumes (PTVs), statistically significant differences were observed in prescribed dose coverage for CC, MCDm and MCDw. The differences in mean CI value for the CC algorithm and mean HI value for MCDm and MCDw were statistically significant. There is a statistically significant difference in the number of MUs for MCDm and MCDw compared to SS. Conclusion: All investigated algorithms succeed in managing the restrictive conditions of the clinical goals. This study shows the drawbacks of the CC algorithm compared to other algorithms used.

  • Open Access

    Impact of stringent tolerance criteria on verification of absorbed dose distributions and evaluation through inhomogeneous media

    by Nevena Obajdin, Djeni Smilovic-Radojcic, David Rajlic, Manda Svabic-Kolacio, Slaven Jurkovic

    Advances of radiation delivery devices have increased the complexity of the radiation oncology treatments. Herewith, outcome of the treatment, as well as patient safety, strongly depend on the consistency of absorbed dose delivery. Both can be ensured by comprehensive system of verification of calculated absorbed dose distributions. Standard method is evaluation of calculated absorbed dose distribution according to gamma method, using a 2-D detector and a homogeneous phantom, to obtain measured dose distribution. Purpose of this research was to investigate the influence of tolerance criteria on gamma passing rate. Additionally, the agreement in heterogeneous phantom was analysed. Absorbed dose calculations were performed using systems Monaco and XiO. Detector with 1020 ionization chambers in homogeneous phantom and semi-anthropomorphic phantom was used for measurements. Absorbed dose distributions of around 3500 patients were analysed using gamma method. In homogeneous phantom, average gamma passing rates were within tolerance for 3 %/2 mm. For measurements in heterogeneous media, the highest average gamma passing rate was obtained for small volumes of medium treatment complexity (γ¯=93.84%), while large volumes of treatment with low complexity yielded the lowest gamma passing rates (γ¯= 83.22%).

  • The role of self-evaluation and education of radiographers involved in a breast cancer screening program at Clinical Hospital Center Rijeka

    by P. Valković Zujić, A. Božanić, S. Jurković, D. Šegota, E. Grgurević Dujmić, B. Čandrlić, M. Karić