Magnetic resonance fingerprinting with dictionary‐based fat and water separation (DBFW MRF): A multi‐component approach
Open Access
- 21 December 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 81 (5) , 3032-3045
Abstract
Purpose: To obtain a fast and robust fat‐water separation with simultaneous estimation of water T1, fat T1, and fat fraction maps.Methods: We modified an MR fingerprinting (MRF) framework to use a single dictionary combination of a water and fat dictionary. A variable TE acquisition pattern with maximum TE = 4.8 ms was used to increase the fat–water separability. Radiofrequency (RF) spoiling was used to reduce the size of the dictionary by reducing T2 sensitivity. The technique was compared both in vitro and in vivo to an MRF method that incorporated 3‐point Dixon (DIXON MRF), as well as Cartesian IDEAL with different acquisition parameters.Results: The proposed dictionary‐based fat–water separation technique (DBFW MRF) successfully provided fat fraction, water, and fat T1, B0, and B1+ maps both in vitro and in vivo. The fat fraction and water T1 values obtained with DBFW MRF show excellent agreement with DIXON MRF as well as with the reference values obtained using a Cartesian IDEAL with a long TR (concordance correlation coefficient: 0.97/0.99 for fat fraction–water T1). Whereas fat fraction values with Cartesian IDEAL were degraded in the presence of T1 saturation, MRF methods successfully estimated and accounted for T1 in the fat fraction estimates.Conclusion: The DBFW MRF technique can successfully provide T1 and fat fraction quantification in under 20 s per slice, intrinsically correcting T1 biases typical of fast Dixon techniques. These features could improve the diagnostic quality and use of images in presence of fat.Keywords
Funding Information
- Instituto Nazionale di Fisica Nucleare
- European Commission (656937)
This publication has 53 references indexed in Scilit:
- ISMRM workshop on fat–water separation: Insights, applications and progress in MRIMagnetic Resonance in Medicine, 2012
- Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopyJournal of Magnetic Resonance Imaging, 2011
- Quantification of Liver Fat with Magnetic Resonance ImagingMagnetic Resonance Imaging Clinics of North America, 2010
- Myocardial Fat ImagingCurrent Cardiovascular Imaging Reports, 2010
- Fast spin‐echo triple‐echo dixon (fTED) technique for efficient T2‐weighted water and fat imagingMagnetic Resonance in Medicine, 2007
- Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): Application with fast spin‐echo imagingMagnetic Resonance in Medicine, 2005
- Fat and water separation in balanced steady-state free precession using the Dixon methodMagnetic Resonance in Medicine, 2004
- Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon techniqueJournal of Magnetic Resonance Imaging, 1995
- Unsuppressed fat in the right anterior diaphragmatic region on fat‐suppressed T2‐weighted fast spin‐echo MR imagesJournal of Magnetic Resonance Imaging, 1995
- Reconstruction by weighted correlation for MRI with time-varying gradientsIEEE Transactions on Medical Imaging, 1988