Elimination of Systematic Mass Measurement Errors in Liquid Chromatography−Mass Spectrometry Based Proteomics Using Regression Models and a Priori Partial Knowledge of the Sample Content
- 29 December 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (3) , 693-706
Abstract
The high mass measurement accuracy and precision available with recently developed mass spectrometers is increasingly used in proteomics analyses to confidently identify tryptic peptides from complex mixtures of proteins, as well as post-translational modifications and peptides from nonannotated proteins. To take full advantage of high mass measurement accuracy instruments, it is necessary to limit systematic mass measurement errors. It is well known that errors in m/z measurements can be affected by experimental parameters that include, for example, outdated calibration coefficients, ion intensity, and temperature changes during the measurement. Traditionally, these variations have been corrected through the use of internal calibrants (well-characterized standards introduced with the sample being analyzed). In this paper, we describe an alternative approach where the calibration is provided through the use of a priori knowledge of the sample being analyzed. Such an approach has previously been demonstrated based on the dependence of systematic error on m/z alone. To incorporate additional explanatory variables, we employed multidimensional, nonparametric regression models, which were evaluated using several commercially available instruments. The applied approach is shown to remove any noticeable biases from the overall mass measurement errors and decreases the overall standard deviation of the mass measurement error distribution by 1.2−2-fold, depending on instrument type. Subsequent reduction of the random errors based on multiple measurements over consecutive spectra further improves accuracy and results in an overall decrease of the standard deviation by 1.8−3.7-fold. This new procedure will decrease the false discovery rates for peptide identifications using high-accuracy mass measurements.Keywords
This publication has 34 references indexed in Scilit:
- Methods, algorithms and tools in computational proteomics: A practical point of viewProteomics, 2007
- Spatial mapping of protein abundances in the mouse brain by voxelation integrated with high-throughput liquid chromatography–mass spectrometryGenome Research, 2007
- Nonparametric Mass Calibration Using Hundreds of Internal CalibrantsAnalytical Chemistry, 2007
- Robust Algorithm for Alignment of Liquid Chromatography−Mass Spectrometry Analyses in an Accurate Mass and Time Tag Data Analysis PipelineAnalytical Chemistry, 2006
- Optimization and Use of Peptide Mass Measurement Accuracy in Shotgun ProteomicsMolecular & Cellular Proteomics, 2006
- Advances in proteomics data analysis and display using an accurate mass and time tag approachMass Spectrometry Reviews, 2006
- Characterization of the Mouse Brain Proteome Using Global Proteomic Analysis Complemented with Cysteinyl-Peptide EnrichmentJournal of Proteome Research, 2006
- VEMS 3.0: Algorithms and Computational Tools for Tandem Mass Spectrometry Based Identification of Post-translational Modifications in ProteinsJournal of Proteome Research, 2005
- Multicomponent Internal Recalibration of an LC−FTICR-MS Analysis Employing a Partially Characterized Complex Peptide Mixture: Systematic and Random ErrorsAnalytical Chemistry, 2005
- Improved precision and accuracy for high‐performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometric exact mass measurement of small molecules from the simultaneous and controlled introduction of internal calibrants via a second electrospray nebuliserRapid Communications in Mass Spectrometry, 2004