Abstract
Conventional model based predictive control for cascade H-bridge multilevel STATCOM produces a different switching pattern for different cells. As a consequence, stresses, DC-link imbalance and active power losses are generated among the cells. To solve the aforementioned issues, this paper proposes to include a switcher of redundant vectors on the conventional model based predictive method. Additionally, improve the performance in terms of total harmonic distortion and remain focus the reactive power compensation. Simulation results are analyzed to verify the effectiveness of this proposal.Keywords
This publication has 9 references indexed in Scilit:
- Model Predictive Control: MPC's Role in the Evolution of Power ElectronicsIEEE Industrial Electronics Magazine, 2015
- Phase-Shifted Carrier Modulation Techniques for Cascaded H-Bridge Multilevel ConvertersIEEE Transactions on Industrial Electronics, 2015
- State feedback control strategy and voltage balancing scheme for a transformer‐less STATic synchronous COMpensator based on cascaded H‐bridge converterIET Power Electronics, 2015
- Operation of Cascaded H-Bridge Multilevel Converters for Large-Scale Photovoltaic Power Plants Under Bridge FailuresIEEE Transactions on Industrial Electronics, 2015
- Study of a state-of-the art M-STATCOM2015
- Finite-set model predictive control and DC-link capacitor voltages balancing for three-level NPC inverters2014
- A New Reactive Current Reference Algorithm for the STATCOM System Based on Cascaded Multilevel InvertersIEEE Transactions on Power Electronics, 2014
- A novel voltage balancing modulation scheme used in cascaded H-bridge multilevel STATCOMs2013
- Voltage balancing characteristics for a cascaded H-bridge multi-level StatCom employing space vector modulation2012