Abstract
We report the fabrication and evaluation of a PMMA electrostatic comb-drive microactuator using hot embossing and ultra-precision cutting technology. First, a two-step silicon mold is fabricated by bulk micromachining technology. Next, comb-drive microactuator structures are formed on a PMMA plate by hot embossing. Both finger width and gap between fingers are 5μm, and finger thickness is larger than 70μm. Then, the PMMA layer that remained after hot embossing is removed by ultra-precision cutting to release the movable parts. Last, the device is coated with a gold layer for the electrode. The PMMA comb-drive microactuator has been tested successfully.

This publication has 6 references indexed in Scilit: