Abstract
Summary: Typical load‐bearing light gauge steel frame (LSF) walls are made of conventional lipped channel section studs and gypsum plasterboards. Current research at the Queensland University of Technology is investigating the effects of using new thin‐walled stud sections on the fire‐resistant rating of LSF walls, in particular, the use of hollow flange channel (HFC) sections. A sound knowledge on the thermal performance of these LSF walls is essential, but expensive and time‐consuming nature of fire tests has acted as a barrier. In this study, finite element models were developed to predict the thermal performance of load‐bearing LSF walls made of HFC section studs exposed to fire on one side. The developed models were validated using the results of five full‐scale standard fire tests of LSF walls. They were then extended to perform a parametric study where the effects of stud dimensions, geometries, spacings and wall configuration were evaluated. The hot and cold flange time‐temperature profiles of HFC studs were developed as a function of the aforementioned parameters, which can be used to predict the fire resistance ratings of LSF walls. This paper presents the fire tests, and the details of the developed finite element models and the thermal performance results of LSF walls made of HFC studs. Copyright © 2015 John Wiley & Sons, Ltd.Keywords
Funding Information
- Australian Research Council
This publication has 19 references indexed in Scilit:
- Numerical studies of gypsum plasterboard panels under standard fire conditionsFire Safety Journal, 2012
- Thermal Performance of Composite Panels Under Fire Conditions Using Numerical Studies: Plasterboards, Rockwool, Glass Fibre and Cellulose InsulationsFire Technology, 2012
- Modelling thermal performance of gypsum plasterboard‐lined light timber frame walls using SAFIR and TASEFFire and Materials, 2010
- Effect of moisture transfer on specific heat of gypsum plasterboard at high temperaturesConstruction and Building Materials, 2009
- Factors Influencing Fire Resistance of Load-bearing Steel Stud WallsFire Technology, 2005
- An experimental study of loaded full-scale cold-formed thin-walled steel structural panels under fire conditionsFire Safety Journal, 2005
- Thermal performance of cold-formed thin-walled steel panel systems in fireFire Safety Journal, 2003
- Thermal properties of gypsum plasterboard at high temperaturesFire and Materials, 2002
- A model for predicting heat transfer through noninsulated unloaded steel-stud gypsum board wall assemblies exposed to fireFire Technology, 1996
- A model for predicting heat transfer through gypsum‐board/wood‐stud walls exposed to fireFire and Materials, 1994