A Prototype Software System for Intra-procedural Staff Dose Monitoring and Virtual Reality Training for Fluoroscopically Guided Interventional Procedures
- 24 February 2023
- journal article
- research article
- Published by Springer Nature in Journal of Digital Imaging
- Vol. 36 (3) , 1091-1109
Abstract
Staff dose management in fluoroscopically guided interventional procedures is a continuing problem. The scattered radiation display system (SDS), which our group has developed, provides in-room visual feedback of scatter dose to staff members during fluoroscopically guided interventional (FGI) procedures as well as extra-procedure staff and resident training. There have been a number of virtual safety training systems developed that provide detailed feedback for staff, but utilize expensive graphics processing units (GPUs) and dosimeter systems, or interaction with the x-ray system in a manner which entails additional radiation exposure and is not compatible with the As Low as Reasonably Achievable paradigm. The SDS, on the other hand, incorporates a library of look-up-table (LUT) room scatter distributions determined using the EGSnrc Monte Carlo software, which facilitates accurate and rapid system update without the need for GPUs. Real-time display of these distributions is provided for feedback to staff during a procedure. After a procedure is completed, machine parameter and staff position log files are stored, retaining all of the exposure and geometric information for future review. A graphic user interface (GUI) in Unity3D enables procedure playback and interactive virtual-reality (VR) staff and resident training with virtual control of exposure conditions using an Oculus headset and controller. Improved staff and resident awareness using this system should lead to increased safety and reduced occupational dose.Keywords
Funding Information
- Canon Medical Systems Corporation
This publication has 11 references indexed in Scilit:
- Estimating Compton scatter distributions with a regressional neural network for use in a real-time staff dose management system for fluoroscopic proceduresProceedings of SPIE, 2021
- Methods for object tracking and shadowing in a top-down view virtual reality scattered radiation display system (SDS) for fluoroscopically-guided procedures2020
- Considerations for accurate inclusion of staff member body tracking in a top-down view virtual reality display of a scattered radiation dose map during fluoroscopic interventional procedures2020
- Development of a real-time scattered radiation display for staff dose reduction during fluoroscopic interventional procedures2019
- Staff Doses in Interventional Radiology: A National SurveyJournal of Vascular and Interventional Radiology, 2012
- Radiation protection of medical staff in the latest draft of the revised Euratom Basic Safety Standards directiveRadiation Measurements, 2011
- Verification of the performance accuracy of a real-time skin-dose tracking system for interventional fluoroscopic proceduresProceedings of SPIE, 2011
- virtX – Evaluation of a Computer-based Training System for Mobile C-arm Systems in Trauma and Orthopedic SurgeryMethods of Information in Medicine, 2008
- Fluoroscopy: Patient Radiation Exposure IssuesRadioGraphics, 2001
- Computerized three‐dimensional segmented human anatomyMedical Physics, 1994