    Physician scatter dose in interventional CT fluoroscopy

    by Emily A. Knott, Jonathan L. Troville, Carlos Alberto Reynoso, Sean D. Rose, Martin G. Wagner, Fred T. Lee, Jeffery L. Radtke, Daniel R. Anderson, Annie Zlevor, Meghan G. Lubner, et al.

    Purpose: To quantify operator dose in interventional CT fluoroscopy (CTF) procedures and compare to catheterization laboratory and interventional radiology procedures.Methods: Fifteen studies quantifying operator scatter dose for c‐arm fluoroscopy and CTF were reviewed from a literature survey. The dose provided in each study was normalized to skin entrance air kerma and air kerma rate including backscatter. The average air kerma rate and exposure duration were calculated and compared between c‐arm fluoroscopy and CTF. To enable operator scatter dose calculations in CTF procedures, a model was created which scaled the dose from a reference condition.Results: Our literature survey indicated that for CTF relative to c‐arm fluoroscopy: (1) the mean air kerma rate is 3.5 times higher, while (2) the mean exposure duration is 31.6 times lower. On average, a physician would have to perform 9.1 times (i.e., 31.6/3.5) more CTF procedures relative to c‐arm fluoroscopy procedure to receive equal operator scatter doses. Our own experimental measurements provided scaling factors allowing physician scatter dose to be obtained at any rotation time, tube current, beam collimation, or beam energy.Conclusion: Our results shed light onto a currently mis‐understood issue in radiology. Namely, that physicians receive more dose from CT relative to c‐arm fluoroscopy motivating them to retreat from the room during interventional exposures. Our literature review and experimental measurements indicate the opposite it true; interventional CT produces on average nine times less physician dose relative to c‐arm procedures. Our method allows for prospective/retrospective determination of an individual's dose.


  • Open Access

    Technical note: A comparison of physician doses in C‐Arm and CT fluoroscopy procedures

    by Jonathan Troville, Emily Knott, Carlos Alberto Reynoso‐Mejia, Martin Wagner, Fred T. Lee, Timothy P. Szczykutowicz

    Purpose: We address the misconception that the typical physician dose is higher for CT fluoroscopy (CTF) procedures compared to C‐Arm procedures.Methods: We compare physician scatter doses using two methods: a literature review of reported doses and a model based on a modified form of the dose area product (DAP). We define this modified form of DAP, “cumulative absorbed DAP,” as the product of the area of the x‐ray beam striking the patient, the dose rate per unit area, and the exposure time.Results: The patient entrance dose rate for C‐Arm fluoroscopy (0.2 mGy/s) was found to be 15 times lower than for CT fluoroscopy (3 mGy/s). A typical beam entrance area for C‐Arm fluoroscopy reported in the literature was found to be 10.6 × 10.6 cm (112 cm2), whereas for CTF was 0.75 × 32 cm (24 cm2). The absorbed DAP rate for C‐Arm fluoroscopy (22 mGy*cm2/s) was found to be 3.3 times lower than for CTF (72 mGy*cm2/s). The mean fluoroscopy time for C‐Arm procedures (710 s) was found to be 21 times higher than for CT fluoroscopy procedures (23 s). The cumulative absorbed DAP for C‐Arm procedures was found to be 9.4 times higher when compared to CT procedures (1.59 mGy*m2 vs. 0.17 mGy*m2).Conclusions: The higher fluoroscopy time in C‐Arm procedures leads to a much lower cumulative DAP (i.e., physician scatter dose) in CTF procedures. This result can inform interventional physicians deciding on whether to perform inter‐procedural imaging inside the room as opposed to retreating from the room.


  • A Prototype Software System for Intra-procedural Staff Dose Monitoring and Virtual Reality Training for Fluoroscopically Guided Interventional Procedures

    by Jonathan Troville, Stephen Rudin, Daniel R. Bednarek

    Staff dose management in fluoroscopically guided interventional procedures is a continuing problem. The scattered radiation display system (SDS), which our group has developed, provides in-room visual feedback of scatter dose to staff members during fluoroscopically guided interventional (FGI) procedures as well as extra-procedure staff and resident training. There have been a number of virtual safety training systems developed that provide detailed feedback for staff, but utilize expensive graphics processing units (GPUs) and dosimeter systems, or interaction with the x-ray system in a manner which entails additional radiation exposure and is not compatible with the As Low as Reasonably Achievable paradigm. The SDS, on the other hand, incorporates a library of look-up-table (LUT) room scatter distributions determined using the EGSnrc Monte Carlo software, which facilitates accurate and rapid system update without the need for GPUs. Real-time display of these distributions is provided for feedback to staff during a procedure. After a procedure is completed, machine parameter and staff position log files are stored, retaining all of the exposure and geometric information for future review. A graphic user interface (GUI) in Unity3D enables procedure playback and interactive virtual-reality (VR) staff and resident training with virtual control of exposure conditions using an Oculus headset and controller. Improved staff and resident awareness using this system should lead to increased safety and reduced occupational dose.


  • Methods for object tracking and shadowing in a top-down view virtual reality scattered radiation display system (SDS) for fluoroscopically-guided procedures

    by Jonathan Troville, Chao Guo, Stephen Rudin, Daniel R. Bednarek

    We have developed a prototype scatter-display system (SDS) which includes a top-down view, virtual reality (VR) representation of an interventional room containing a color-coded scatter dose rate distribution in real-time. To represent various attenuating objects of interest in the room, such as the C-Arm gantry and ceiling mounted shield, the STL toolbox in Matlab was implemented to produce a 3D VR description of the objects. Attenuation by objects in the room will alter the dose distribution and may lead to shielding of individual staff members, and thus representation of those objects in the software is needed for precise dose rate estimations. Determination of the spatial regions of attenuation requires accurate specification of object position. To retain identification of a ceiling mounted shield, we implemented an open-source package which maintains object recognition using the depth camera feed of a Microsoft Kinect V2 and the features-from-accelerated-segment- test (FAST) algorithm in OpenCV for a dense sampling of salient features. The depth information from the identified object is transferred to an open-source robot operating system (ROS) wrapper for specification of the 3D position to be fed into the SDS. To compute the C-Arm gantry position, we take advantage of a controller area network (CAN) bus interfaced with the angiography system’s application programming interface (API). Methods for computing gantry and ceiling mounted shield shadow regions are discussed and demonstrated. FAST was applied to the ceiling-shield assembly’s flange with reliable recognition. Including object attenuation of room scatter in the SDS will facilitate accurate dose rate computation.


  • Considerations for accurate inclusion of staff member body tracking in a top-down view virtual reality display of a scattered radiation dose map during fluoroscopic interventional procedures

    by Jonathan Troville, Chao Guo, Stephen Rudin, Daniel R. Bednarek

    The functionality of a real-time, top-down view virtual reality (VR) display of scattered radiation during fluoroscopic interventional procedures is being expanded to incorporate automatic input of staff member locations. Microsoft Kinect V2 depth sensing camera input was integrated into an open-source Robot Operating System (ROS) wrapper to facilitate automatic extraction of relative landmark body feature coordinates. Coordinates for the torso are selected to represent the staff member location in the selected plane of scatter; these coordinates are stored in a text file to be input into the real-time scatter display system (SDS). Accuracy of the depth sensing camera was evaluated using a pinhole camera model. This model was also implemented in an ROS wrapper to calibrate the Microsoft Kinect V2. Calibrated values were then implemented within a coordinate transformation algorithm which converts the physical distance measurements in the frame of the Kinect to normalized coordinates used in Matlab for visualization of the top-down horizontal plane of the interventional suite. Impact on real-time performance was evaluated for both staff member position update on-screen as well as for the update of SDS image frames.