Retention of crowns cemented on implant abutments with temporary cements
Authors:
Open Access
- 1 January 2014
- journal article
- research article
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 33 (6) , 835-844
Abstract
This study was to examine the retentive force of crowns to implant abutments with commercial temporary cements. Six different temporary cements were investigated. Cast crowns were cemented to the abutments using each cement and their retentive forces to abutments were determined 7 or 28 days after cementing (n=10). The retentive force of the cements to abutments varied widelyamong the products [27–109 N (7-day), 18–80 N (28-days)]. The retentive force of all the cements was not reduced as the time elapsed, except for two products tested. The polycarboxylate cements and paste-mixing type eugenol-free cements revealed comparable retentive force after 28 days of storage. The powder-liquid type cements showed a positive correlation (p<0.05) between the retentive force and the shear strength, while a negative correlation (p<0.05) was obtained for paste-mixing type cement between the retentive force and compressive strength. Mechanical strength of temporary cements could not be a prominent predicting factor for retention of the crowns on the abutments.Keywords
This publication has 17 references indexed in Scilit:
- Crown retention and flexural strength of eight provisional cementsThe Journal of Prosthetic Dentistry, 2007
- Cement Selection for Cement‐Retained Crown Technique with Dental ImplantsJournal of Prosthodontics, 2007
- The Effect of Fatigue Damage on the Force Required to Remove a Restoration in a Cement‐Retained Implant SystemJournal of Prosthodontics, 2006
- The effects of abutment taper, length and cement type on resistance to dislodgement of cement‐retained, implant‐supported restorationsJournal of Prosthodontics, 2003
- Fluids and Microbial Penetration in the Internal Part of Cement‐Retained Versus Screw‐Retained Implant‐Abutment ConnectionsJournal of Periodontology, 2001
- Retentive and compressive strengths of modified zinc oxide–eugenol cementsJournal of Dentistry, 2000
- Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistryThe Journal of Prosthetic Dentistry, 1997
- Effect of aging on temporary cement retention in vitroThe Journal of Prosthetic Dentistry, 1991
- A survey of crown and fixed partial denture failures: Length of service and reasons for replacementThe Journal of Prosthetic Dentistry, 1986
- The effect of temperature on the compressive and tensile strengths of cementsThe Journal of Prosthetic Dentistry, 1983