Ureteral stent sleeve for early detection of hydronephrosis
Open Access
- 18 March 2026
- journal article
- research article
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 97
Abstract
Hydronephrosis, a serious complication of ureteral stents, can lead to deterioration of renal function due to prolonged increased intrarenal pressure. Currently, the only way to diagnose hydronephrosis is radiographic imaging, and a continuous, non-invasive method is not available. This study introduces the ureteral stent sleeve, UroSleeve, a modular wireless pressure monitoring system that is designed to integrate seamlessly with standard ureteral stents without altering their existing designs or manufacturing processes. The UroSleeve incorporates a flexible printed-circuit-board-based spiral antenna and a surface-micromachined capacitive pressure sensor, forming an inductor-capacitor tank circuit capable of wireless telemetry through near-field inductive coupling. The device was evaluated in an ex vivo porcine kidney model whose internal pressure was externally controlled to mimic a hydronephrosis condition, and kidney pressure changes were successfully monitored by detecting shifts in the resonant frequency of the device. Key results demonstrated a high sensitivity with -5.3 ± 0.74 kHz/mmHg with a baseline resonant frequency of 15.234 MHz at 8.5 mmHg. The frequency response showed a strong correlation with kidney pressure, and the device maintained consistent performance in a relevant biological environment. The results indicate that UroSleeve offers a practical and versatile solution for wireless intrarenal pressure monitoring, amenable to future clinical translation.Keywords
All Related Versions
Funding Information
- Gouvernement du Canada | Instituts de Recherche en Santé du Canada | CIHR Skin Research Training Centre (CPG-158279)
- Gouvernement du Canada | Instituts de Recherche en Santé du Canada | CIHR Skin Research Training Centre (CPG-158279)
- Gouvernement du Canada | Instituts de Recherche en Santé du Canada | CIHR Skin Research Training Centre (CPG-158279)
- Gouvernement du Canada | Instituts de Recherche en Santé du Canada | CIHR Skin Research Training Centre (CPG-158279)
- Gouvernement du Canada | Instituts de Recherche en Santé du Canada | CIHR Skin Research Training Centre (CPG-158279)
- Gouvernement du Canada | Instituts de Recherche en Santé du Canada | CIHR Skin Research Training Centre (CPG-158279)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (CHRP 523795-18)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (CHRP 523795-18)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (CHRP 523795-18)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (CHRP 523795-18)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (CHRP 523795-18)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (CHRP 523795-18)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (CHRP 523795-18)
- Deutsche Forschungsgemeinschaft (447437311)
This publication has 27 references indexed in Scilit:
- Intelligent Ureteral Stent Placeable via Standard Procedure for Kidney Pressure Telemetry: An Ex-Vivo StudyAnnals of Biomedical Engineering, 2024
- Intelligent Ureteral Stent for Early Detection of HydronephrosisAdvanced Materials Technologies, 2021
- Hydronephrosis severity clarifies prognosis and guides management for emergency department patients with acute ureteral colicCanadian Journal of Emergency Medicine, 2021
- Evaluation of stone free rates in early versus delayed primary ureteroscopy: time does matterWorld Journal of Urology, 2020
- Recent progress on parylene C polymer for biomedical applications: A reviewProgress in Organic Coatings, 2020
- A complete analytical model for clamped edge circular diaphragm non-touch and touch mode capacitive pressure sensorMicrosystem Technologies, 2015
- Intelligent telemetric stent for wireless monitoring of intravascular pressure and its in vivo testingBiomedical Microdevices, 2014
- Design and Analysis of Spiral Inductors2014
- Touch mode capacitive pressure sensorsSensors and Actuators A: Physical, 1999
- Experience with New Double J Ureteral Catheter StentJournal of Urology, 1978