Kenichi Takahata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kenichi Takahata has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Alireza Nojeh
The University of British Columbia
7 shared publications Babak Assadsangabi
Department of Electrical and Computer Engineering, The University of British Columbia, Vancouver, BC V6T 1Z4, Canada
5 shared publicationsSayed Mohammad Hashem Jayhooni
Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada
5 shared publicationsKyle Searles
School of Biomedical Engineering, University of British Columbia, Vancouver, Canada
4 shared publications- Mohamed Sultan Mohamed Ali
Department of Electrical Engineering, College of Engineering, Qatar University, Doha, Qatar
4 shared publications Geoffrey Hohert
Integrative Oncology, BC Cancer Research Institute, Vancouver, Canada
3 shared publications
Latest Publications
- Open Access
- 7 August 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 410
A distal rotary scanner using precessional mirror disc for 360° endoscopic multimodal imaging
- 7 August 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 410
Open AccessA distal rotary scanner using precessional mirror disc for 360° endoscopic multimodal imaging
- Open Access
- 18 March 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 97
Ureteral stent sleeve for early detection of hydronephrosis
Hydronephrosis, a serious complication of ureteral stents, can lead to deterioration of renal function due to prolonged increased intrarenal pressure. Currently, the only way to diagnose hydronephrosis is radiographic imaging, and a continuous, non-invasive method is not available. This study introduces the ureteral stent sleeve, UroSleeve, a modular wireless pressure monitoring system that is designed to integrate seamlessly with standard ureteral stents without altering their existing designs or manufacturing processes. The UroSleeve incorporates a flexible printed-circuit-board-based spiral antenna and a surface-micromachined capacitive pressure sensor, forming an inductor-capacitor tank circuit capable of wireless telemetry through near-field inductive coupling. The device was evaluated in an ex vivo porcine kidney model whose internal pressure was externally controlled to mimic a hydronephrosis condition, and kidney pressure changes were successfully monitored by detecting shifts in the resonant frequency of the device. Key results demonstrated a high sensitivity with -5.3 ± 0.74 kHz/mmHg with a baseline resonant frequency of 15.234 MHz at 8.5 mmHg. The frequency response showed a strong correlation with kidney pressure, and the device maintained consistent performance in a relevant biological environment. The results indicate that UroSleeve offers a practical and versatile solution for wireless intrarenal pressure monitoring, amenable to future clinical translation.
- 18 March 2026
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 12 (1) , 97
Open AccessUreteral stent sleeve for early detection of hydronephrosis
Hydronephrosis, a serious complication of ureteral stents, can lead to deterioration of renal function due to prolonged increased intrarenal pressure. Currently, the only way to diagnose hydronephrosis is radiographic imaging, and a continuous, non-invasive method is not available. This study introduces the ureteral stent sleeve, UroSleeve, a modular wireless pressure monitoring system that is designed to integrate seamlessly with standard ureteral stents without altering their existing designs or manufacturing processes. The UroSleeve incorporates a flexible printed-circuit-board-based spiral antenna and a surface-micromachined capacitive pressure sensor, forming an inductor-capacitor tank circuit capable of wireless telemetry through near-field inductive coupling. The device was evaluated in an ex vivo porcine kidney model whose internal pressure was externally controlled to mimic a hydronephrosis condition, and kidney pressure changes were successfully monitored by detecting shifts in the resonant frequency of the device. Key results demonstrated a high sensitivity with -5.3 ± 0.74 kHz/mmHg with a baseline resonant frequency of 15.234 MHz at 8.5 mmHg. The frequency response showed a strong correlation with kidney pressure, and the device maintained consistent performance in a relevant biological environment. The results indicate that UroSleeve offers a practical and versatile solution for wireless intrarenal pressure monitoring, amenable to future clinical translation.
- Open Access
- 20 January 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (1) , 111
A Precessing-Coin-like Rotary Actuator for Distal Endoscope Scanners: Proof-of-Concept Study
This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe’s optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging. This new scanner architecture removes the need for a separate prism mirror and holding mechanics to drastically simplify the scanner design and thus, potentially enhancing device miniaturization and reliability. The first proof-of-concept is developed using 3D printing and experimentally analyzed to reveal the ability of both angular stepping at 45° and high-speed rotation up to 1500 rpm within the biologically safe temperature range, a key function for multimodal imaging. Preliminary optical testing demonstrates continuous circumferential scanning of the laser beam with no blind spot caused by power leads to the actuator. The results indicate the fundamental feasibility of the developed actuator as an endoscopic distal scanner, a significant step to further development toward advancing optical endoscope technology.
- 20 January 2025
- Published by MDPI AG in Micromachines
- Vol. 16 (1) , 111
Open AccessA Precessing-Coin-like Rotary Actuator for Distal Endoscope Scanners: Proof-of-Concept Study
This paper presents, for the first time, a rotary actuator functionalized by an inclined disc rotor that serves as a distal optical scanner for endoscopic probes, enabling side-viewing endoscopy in luminal organs using different imaging/analytic modalities such as optical coherence tomography and Raman spectroscopy. This scanner uses a magnetic rotor designed to have a mirror surface on its backside, being electromagnetically driven to roll around the cone-shaped hollow base to create a motion just like a precessing coin. An optical probing beam directed from the probe’s optic fiber is passed through the hollow cone to be incident and bent on the back mirror of the rotating inclined rotor, circulating the probing beam around the scanner for full 360° sideway imaging. This new scanner architecture removes the need for a separate prism mirror and holding mechanics to drastically simplify the scanner design and thus, potentially enhancing device miniaturization and reliability. The first proof-of-concept is developed using 3D printing and experimentally analyzed to reveal the ability of both angular stepping at 45° and high-speed rotation up to 1500 rpm within the biologically safe temperature range, a key function for multimodal imaging. Preliminary optical testing demonstrates continuous circumferential scanning of the laser beam with no blind spot caused by power leads to the actuator. The results indicate the fundamental feasibility of the developed actuator as an endoscopic distal scanner, a significant step to further development toward advancing optical endoscope technology.
- 24 September 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (1) , 180-192
Intelligent Ureteral Stent Placeable via Standard Procedure for Kidney Pressure Telemetry: An Ex-Vivo Study
This paper reports the first telemetric ureteral stent compatible with common placement procedure, enabling wireless sensing and detection of ureteral obstruction and resultant kidney swelling known as hydronephrosis at an early stage. This sensor-integrated “intelligent” ureteral stent is prototyped via the design and fabrication approaches that raise the practicality of the device and tested in a harvested swine kidney-ureter model ex vivo. Leveraging a polymeric double-J stent and micro-electro-mechanical systems technology, the intelligent stent is built by embedding micro pressure sensors and a radiofrequency antenna, forming a resonant circuit that enables wireless kidney pressure monitoring in an operating frequency of 40–50 MHz. The stent device is entirely packaged with Parylene-C for both biocompatibility and electrical insulation of the device in order to function in the real environment including urine, an electrically conductive liquid. A comparison between the results measured in in-vitro and ex-vivo settings show a good match in the sensitivity to applied pressure. In particular, the ex-vivo test in the kidney-ureter model pressurized with artificial urine in a cycled manner demonstrates wireless pressure tracking with a response of 1.3 kHz/mmHg, over pressures up to 37 mmHg that well covers a range of pressure increase known for chronic obstruction. This testing is enabled by the prototype placement into the ex-vivo model using the standard stenting technique and tools without noticeable functional degradation or failures, showing potential compatibility of the device with today’s clinical need as a ureteral stent.
- 24 September 2024
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (1) , 180-192
Intelligent Ureteral Stent Placeable via Standard Procedure for Kidney Pressure Telemetry: An Ex-Vivo Study
This paper reports the first telemetric ureteral stent compatible with common placement procedure, enabling wireless sensing and detection of ureteral obstruction and resultant kidney swelling known as hydronephrosis at an early stage. This sensor-integrated “intelligent” ureteral stent is prototyped via the design and fabrication approaches that raise the practicality of the device and tested in a harvested swine kidney-ureter model ex vivo. Leveraging a polymeric double-J stent and micro-electro-mechanical systems technology, the intelligent stent is built by embedding micro pressure sensors and a radiofrequency antenna, forming a resonant circuit that enables wireless kidney pressure monitoring in an operating frequency of 40–50 MHz. The stent device is entirely packaged with Parylene-C for both biocompatibility and electrical insulation of the device in order to function in the real environment including urine, an electrically conductive liquid. A comparison between the results measured in in-vitro and ex-vivo settings show a good match in the sensitivity to applied pressure. In particular, the ex-vivo test in the kidney-ureter model pressurized with artificial urine in a cycled manner demonstrates wireless pressure tracking with a response of 1.3 kHz/mmHg, over pressures up to 37 mmHg that well covers a range of pressure increase known for chronic obstruction. This testing is enabled by the prototype placement into the ex-vivo model using the standard stenting technique and tools without noticeable functional degradation or failures, showing potential compatibility of the device with today’s clinical need as a ureteral stent.
- 9 March 2024
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 28 (4) , 1-17
A thermally actuated biocompatible flexible micropump for surface adaptable mounting
- 9 March 2024
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 28 (4) , 1-17
A thermally actuated biocompatible flexible micropump for surface adaptable mounting
- 19 February 2024
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 14 (3) , 583-592
Distal planar rotary scanner for endoscopic optical coherence tomography
Optical coherence tomography (OCT) is becoming a more common endoscopic imaging modality for detecting and treating disease given its high resolution and image quality. To use OCT for 3-dimensional imaging of small lumen, embedding an optical scanner at the distal end of an endoscopic probe for circumferential scanning the probing light is a promising way to implement high-quality imaging unachievable with the conventional method of revolving an entire probe. To this end, the present work proposes a hollow and planar micro rotary actuator for its use as an endoscopic distal scanner. A miniaturized design of this ferrofluid-assisted electromagnetic actuator is prototyped to act as a full 360° optical scanner, which is integrated at the tip of a fiber-optic probe together with a gradient-index lens for use with OCT. The scanner is revealed to achieve a notably improved dynamic performance that shows a maximum speed of 6500 rpm, representing 325% of the same reported with the preceding design, while staying below the thermal limit for safe in-vivo use. The scanner is demonstrated to perform real-time OCT using human fingers as live tissue samples for the imaging tests. The acquired images display no shadows from the electrical wires to the scanner, given its hollow architecture that allows the probing light to pass through the actuator body, as well as the quality high enough to differentiate the dermis from the epidermis while resolving individual sweat glands, proving the effectiveness of the prototyped scanner design for endoscopic OCT application.
- 19 February 2024
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 14 (3) , 583-592
Distal planar rotary scanner for endoscopic optical coherence tomography
Optical coherence tomography (OCT) is becoming a more common endoscopic imaging modality for detecting and treating disease given its high resolution and image quality. To use OCT for 3-dimensional imaging of small lumen, embedding an optical scanner at the distal end of an endoscopic probe for circumferential scanning the probing light is a promising way to implement high-quality imaging unachievable with the conventional method of revolving an entire probe. To this end, the present work proposes a hollow and planar micro rotary actuator for its use as an endoscopic distal scanner. A miniaturized design of this ferrofluid-assisted electromagnetic actuator is prototyped to act as a full 360° optical scanner, which is integrated at the tip of a fiber-optic probe together with a gradient-index lens for use with OCT. The scanner is revealed to achieve a notably improved dynamic performance that shows a maximum speed of 6500 rpm, representing 325% of the same reported with the preceding design, while staying below the thermal limit for safe in-vivo use. The scanner is demonstrated to perform real-time OCT using human fingers as live tissue samples for the imaging tests. The acquired images display no shadows from the electrical wires to the scanner, given its hollow architecture that allows the probing light to pass through the actuator body, as well as the quality high enough to differentiate the dermis from the epidermis while resolving individual sweat glands, proving the effectiveness of the prototyped scanner design for endoscopic OCT application.
- 5 June 2023
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 9 (7) , 4392-4403
Electromechanically Functionalized Ureteral Stents for Wireless Obstruction Monitoring
While millions of ureteral stents are placed in patients with urinary tract issues around the world every year, hydronephrosis still poses great danger to these patients as a common complication. In the present work, an intelligent double-J ureteral stent equipped with a micro pressure sensor and antenna circuitry is investigated and prototyped toward enabling continuous wireless monitoring of kidney pressure to detect a ureteral obstruction and the resultant hydronephrosis via the indwelling stent. This electromechanically functionalized "intelligent" ureteral stent acts as a radiofrequency resonator with a pressure-sensitive resonant frequency that can be interrogated using an external antenna to track the local pressure. The prototype passes mechanical bending tests of up to 15 cm radius of curvature and shows wireless sensing with a sensitivity of 3.1 kHz/mmHg in artificial urine, which represents 25× enhancement over the preceding design, using an in vitro model with test tissue layers and a pressure range that functions within the conditions found in hydronephrotic conditions. These promising results are expected to propel intelligent ureteral stent technology into further clinical research.
- 5 June 2023
- Published by American Chemical Society (ACS) in ACS Biomaterials Science & Engineering
- Vol. 9 (7) , 4392-4403
Electromechanically Functionalized Ureteral Stents for Wireless Obstruction Monitoring
While millions of ureteral stents are placed in patients with urinary tract issues around the world every year, hydronephrosis still poses great danger to these patients as a common complication. In the present work, an intelligent double-J ureteral stent equipped with a micro pressure sensor and antenna circuitry is investigated and prototyped toward enabling continuous wireless monitoring of kidney pressure to detect a ureteral obstruction and the resultant hydronephrosis via the indwelling stent. This electromechanically functionalized "intelligent" ureteral stent acts as a radiofrequency resonator with a pressure-sensitive resonant frequency that can be interrogated using an external antenna to track the local pressure. The prototype passes mechanical bending tests of up to 15 cm radius of curvature and shows wireless sensing with a sensitivity of 3.1 kHz/mmHg in artificial urine, which represents 25× enhancement over the preceding design, using an in vitro model with test tissue layers and a pressure range that functions within the conditions found in hydronephrotic conditions. These promising results are expected to propel intelligent ureteral stent technology into further clinical research.
- Open Access
- 23 December 2022
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 8 (1) , 1-14
Switch mode capacitive pressure sensors
Switch mode capacitive pressure sensors are proposed as a new class of microfabricated devices that transform pressure into a mechanically switching capacitance to form an analog-to-digital signal with zero power, high sensitivity, and a high signal-to-noise ratio. A pressure-sensitive gold membrane suspended over a capacitive cavity makes ohmic contact with patterned gold leads on the substrate, closing circuits to fixed on-chip capacitors outside the cavity and leading to significant step responses. This function is achieved by allocating the switch leads on the part of the counter electrode area, while the remaining area is used for touch mode analog capacitive sensing. The sensor microchip is prototyped through a novel design approach to surface micromachining that integrates micro-Tesla valves for vacuum sealing the sensor cavity, showing an unprecedented response to applied pressure. For a gauge pressure range of 0–120 mmHg, the sensor exhibits an increase of 13.21 pF with resultant switch events, each of which ranges from 2.53–3.96 pF every 12–38 mmHg, in addition to the touch mode linear capacitive increase between switches. The equivalent sensitivity is 80–240 fF/mmHg, which is 11–600× more than commercial and reported touch mode sensors operating in similar pressure ranges. The sensor is further demonstrated for wireless pressure tracking by creating a resonant tank with the sensor, showing a 32.5–101.6 kHz/mmHg sensitivity with frequency jumps led by the switch events. The developed sensor, with its promising performance, offers new application opportunities in a variety of device areas, including health care, robotics, industrial control, and environmental monitoring.
- 23 December 2022
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 8 (1) , 1-14
Open AccessSwitch mode capacitive pressure sensors
Switch mode capacitive pressure sensors are proposed as a new class of microfabricated devices that transform pressure into a mechanically switching capacitance to form an analog-to-digital signal with zero power, high sensitivity, and a high signal-to-noise ratio. A pressure-sensitive gold membrane suspended over a capacitive cavity makes ohmic contact with patterned gold leads on the substrate, closing circuits to fixed on-chip capacitors outside the cavity and leading to significant step responses. This function is achieved by allocating the switch leads on the part of the counter electrode area, while the remaining area is used for touch mode analog capacitive sensing. The sensor microchip is prototyped through a novel design approach to surface micromachining that integrates micro-Tesla valves for vacuum sealing the sensor cavity, showing an unprecedented response to applied pressure. For a gauge pressure range of 0–120 mmHg, the sensor exhibits an increase of 13.21 pF with resultant switch events, each of which ranges from 2.53–3.96 pF every 12–38 mmHg, in addition to the touch mode linear capacitive increase between switches. The equivalent sensitivity is 80–240 fF/mmHg, which is 11–600× more than commercial and reported touch mode sensors operating in similar pressure ranges. The sensor is further demonstrated for wireless pressure tracking by creating a resonant tank with the sensor, showing a 32.5–101.6 kHz/mmHg sensitivity with frequency jumps led by the switch events. The developed sensor, with its promising performance, offers new application opportunities in a variety of device areas, including health care, robotics, industrial control, and environmental monitoring.
- 16 July 2022
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 345
A planar micro rotary actuator for endoscopic optical scanning
- 16 July 2022
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 345
A planar micro rotary actuator for endoscopic optical scanning
- Open Access
- 3 March 2022
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 58 (8) , 318-320
Flex‐circuit resonant chip with Y5V multilayer capacitor for wireless temperature tracking
This paper reports the first wireless thermometric device enabled using a surface‐mount capacitor microchip as the sensing element, offering a low‐cost, disposable, and flexible sensor potentially suitable for a wide range of application areas. The device is developed in the form of a resonant‐circuit chip, in which a Y5V‐type multilayer capacitor microchip that exhibits significant temperature dependence serves as a thermoresponsive element that varies the resonant frequency of the circuit upon a temperature change. The wireless sensor chips prototyped in conjunction with the flex‐circuit technology are tested to show their intended function with the frequency responses of up to 129 kHz/°C for ambient temperature variations. Wireless temperature tracking of a fluid‐flowing channel is experimentally demonstrated using the prototype.
- 3 March 2022
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 58 (8) , 318-320
Open AccessFlex‐circuit resonant chip with Y5V multilayer capacitor for wireless temperature tracking
This paper reports the first wireless thermometric device enabled using a surface‐mount capacitor microchip as the sensing element, offering a low‐cost, disposable, and flexible sensor potentially suitable for a wide range of application areas. The device is developed in the form of a resonant‐circuit chip, in which a Y5V‐type multilayer capacitor microchip that exhibits significant temperature dependence serves as a thermoresponsive element that varies the resonant frequency of the circuit upon a temperature change. The wireless sensor chips prototyped in conjunction with the flex‐circuit technology are tested to show their intended function with the frequency responses of up to 129 kHz/°C for ambient temperature variations. Wireless temperature tracking of a fluid‐flowing channel is experimentally demonstrated using the prototype.