Comparison of yttrium-90 quantitative imaging by TOF and non-TOF PET in a phantom of liver selective internal radiotherapy
Authors:
- 5 October 2011
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (21) , 6759-6777
Abstract
The aim of this study is to determine the feasibility of achieving quantitative measurement in 90Y-microspheres liver selective internal radiotherapy (SIRT) by imaging 90Y with a conventional non-time of flight (TOF) PET device. Instead of the bremsstrahlung x-rays of the β-decay, the low branch of e−– e+ pair production in the 90Y-decay was used. The activity distribution in a phantom-simulated liver SIRT was obtained by direct 90Y-PET imaging. We tested a LYSO TOF PET and two GSO and BGO non-TOF PET scanners using a 3.6-l cylindrical phantom filled with the 90Y solution containing two sets of hot and cold spheres. The best hot contrast was obtained with the LYSO TOF. It was close to the expected value and remained constant, even for short acquisition times. The LYSO non-TOF was about 10% lower. The GSO performed similarly but degraded for shorter times whilst the BGO was the worst with 40% loss. For the cold spheres, the LYSO TOF and the GSO provided the best results, while the LYSO non-TOF and the BGO were the worst. 90Y PET imaging in liver SIRT is achievable with LYSO TOF. Conventional LYSO and GSO show a loss of contrast and require longer acquisition times. BGO imaging is not feasible for dosimetry calculation.Keywords
This publication has 37 references indexed in Scilit:
- Early Dose Response to Yttrium-90 Microsphere Treatment of Metastatic Liver Cancer by a Patient-Specific Method Using Single Photon Emission Computed Tomography and Positron Emission TomographyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Evaluation of quantitative90Y SPECT based on experimental phantom studiesPhysics in Medicine & Biology, 2008
- Electron tomography: a short overview with an emphasis on the absorption potential model for the forward problemInverse Problems, 2008
- Posttherapy Radiation Safety Considerations in Radiomicrosphere Treatment with 90Y-MicrospheresJournal of Nuclear Medicine, 2007
- Application of the row action maximum likelihood algorithm with spherical basis functions to clinical PET imagingIEEE Transactions on Nuclear Science, 2001
- Visibility of objects in computer simulations of noisy micrographsJournal of Microscopy, 1998
- The ECAT EXACT HRJournal of Computer Assisted Tomography, 1994
- The perception of detail in radioisotope images with Gaussian noisePhysics in Medicine & Biology, 1990
- Zum experimentellen Nachweis von Zweiquantenzerfall beim 0+-0+- bergang des Zr90The European Physical Journal A, 1961
- Predicted 0+ Level inPhysical Review B, 1955