Larry van Elmbt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Larry van Elmbt has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
François Jamar
Department of Nuclear Medicine, Université Catholique de Louvain, Brussels, Belgium
1 shared publicationStanislas Pauwels
Department of Nuclear Medicine, Université Catholique de Louvain, Brussels, Belgium
1 shared publicationStefaan Vandenberghe
MEDISIP Research Group ELIS-IBITECH, University Hospital Ghent, Ghent University, Ghent, Belgium
1 shared publicationStephan Walrand
Department of Nuclear Medicine, Université Catholique de Louvain, Brussels, Belgium
1 shared publication
Latest Publications
- 5 October 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (21) , 6759-6777
Comparison of yttrium-90 quantitative imaging by TOF and non-TOF PET in a phantom of liver selective internal radiotherapy
The aim of this study is to determine the feasibility of achieving quantitative measurement in 90Y-microspheres liver selective internal radiotherapy (SIRT) by imaging 90Y with a conventional non-time of flight (TOF) PET device. Instead of the bremsstrahlung x-rays of the β-decay, the low branch of e−– e+ pair production in the 90Y-decay was used. The activity distribution in a phantom-simulated liver SIRT was obtained by direct 90Y-PET imaging. We tested a LYSO TOF PET and two GSO and BGO non-TOF PET scanners using a 3.6-l cylindrical phantom filled with the 90Y solution containing two sets of hot and cold spheres. The best hot contrast was obtained with the LYSO TOF. It was close to the expected value and remained constant, even for short acquisition times. The LYSO non-TOF was about 10% lower. The GSO performed similarly but degraded for shorter times whilst the BGO was the worst with 40% loss. For the cold spheres, the LYSO TOF and the GSO provided the best results, while the LYSO non-TOF and the BGO were the worst. 90Y PET imaging in liver SIRT is achievable with LYSO TOF. Conventional LYSO and GSO show a loss of contrast and require longer acquisition times. BGO imaging is not feasible for dosimetry calculation.
- 5 October 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (21) , 6759-6777
Comparison of yttrium-90 quantitative imaging by TOF and non-TOF PET in a phantom of liver selective internal radiotherapy
The aim of this study is to determine the feasibility of achieving quantitative measurement in 90Y-microspheres liver selective internal radiotherapy (SIRT) by imaging 90Y with a conventional non-time of flight (TOF) PET device. Instead of the bremsstrahlung x-rays of the β-decay, the low branch of e−– e+ pair production in the 90Y-decay was used. The activity distribution in a phantom-simulated liver SIRT was obtained by direct 90Y-PET imaging. We tested a LYSO TOF PET and two GSO and BGO non-TOF PET scanners using a 3.6-l cylindrical phantom filled with the 90Y solution containing two sets of hot and cold spheres. The best hot contrast was obtained with the LYSO TOF. It was close to the expected value and remained constant, even for short acquisition times. The LYSO non-TOF was about 10% lower. The GSO performed similarly but degraded for shorter times whilst the BGO was the worst with 40% loss. For the cold spheres, the LYSO TOF and the GSO provided the best results, while the LYSO non-TOF and the BGO were the worst. 90Y PET imaging in liver SIRT is achievable with LYSO TOF. Conventional LYSO and GSO show a loss of contrast and require longer acquisition times. BGO imaging is not feasible for dosimetry calculation.