A blood sampling microsystem for pharmacokinetic applications: Design, fabrication, and initial results
Authors:
- 12 October 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (24) , 3495-3503
Abstract
This paper describes a microsystem for automated blood sampling from laboratory mice used in pharmacokinetic studies. Intended to be mounted as a “backpack” on a mouse, it uses a microneedle, reservoir, and an actuator to instantaneously prick the animal for a time-point sample, eliminating the need for a tethered catheter with large dead volume. The blood is collected by capillary effect through a 31–33 gauge microneedle (250–210 μm OD) into a ≈1 μL micromachined steel reservoir. The voice coil actuator provides a peak force of ≈300 mN, which amply exceeds the measured piercing force of mouse skin (i.e., 60–85 mN for a 31-gauge needle with 12° bevel). The sampling system was tested in vitro using a mock vessel with adjustable pressure; the reservoir was filled in In vivo tests on live, anesthetized mice resulted in successful collection of blood into the reservoir. The possible integration of the device in microanalytical systems and the device scalability for multisampling are discussed.Keywords
This publication has 17 references indexed in Scilit:
- On the respective effect of the surface energy and micro-geometry in the cleaning ability of bare and coated steelsColloids and Surfaces A: Physicochemical and Engineering Aspects, 2006
- Ultra-Hydrophilic Transition Metals as Histophilic BiomaterialsMacromolecular Symposia, 2005
- Gender Differences in Mouse Skin Morphology and Specific Effects of Sex Steroids and DehydroepiandrosteroneJournal of Investigative Dermatology, 2005
- Modified stainless steel surfaces targeted to reduce fouling––surface characterizationJournal of Food Engineering, 2004
- Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture forceJournal of Biomechanics, 2004
- Silicon micromachined hollow microneedles for transdermal liquid transportJournal of Microelectromechanical Systems, 2003
- Side-opened out-of-plane microneedles for microfluidic transdermal liquid transferJournal of Microelectromechanical Systems, 2003
- Healthcare Chip for Checking Health Condition from Analysis of Trace Blood Collected by Painless NeedleJapanese Journal of Applied Physics, 2003
- Batch mode micro-electro-discharge machiningJournal of Microelectromechanical Systems, 2002
- Influence of the surface chemistry on the wettability of stainless steelSurface and Interface Analysis, 1994