Improving the Resolution of Kendrick Mass Defect Analysis for Polymer Ions with Fractional Base Units
Open Access
- 1 January 2017
- journal article
- Published by The Mass Spectrometry Society of Japan in Mass Spectrometry
- Vol. 6 (1) , A0055
Abstract
The concept of a fractional base unit for the Kendrick mass defect (KMD) analysis of polymer ions is introduced for the first time. A fraction of the ethylene oxide (EO) repeat unit (namely EO/8) has been used for the KMD analysis of a poly(ethylene oxide) and found to amplify the variations of KMD between monoisotopic and 13C isotopes, producing an isotopically resolved KMD plot at full scale when the KMD plot computed with EO is fuzzy. The expansion of the KMD dimension using a fractional base unit has then been successfully used to unequivocally discriminate all the distributions from a blend of poly(ethylene oxide)s in a high resolution KMD plot calculated with EO/3 as base unit. Extending the concept of fractional base units to other repeat units, the visualization of the co-oligomers from a poly(ethylene oxide-b-propylene oxide-b-ethylene oxide) triblock copolymer has been dramatically improved using a fraction of the propylene oxide repeat unit (namely PO/3) in an oligomer and isotope resolved plot. High resolution KMD plots were eventually calculated from tandem mass spectra of poly(dimethylsiloxane) ions using a fraction of the dimethylsiloxane (DMS) unit (namely DMS/6) with clearer point alignments and a discrimination of all the product ion series, out of reach of the KMD analysis using DMS. Versatile and producing high resolution KMD plots, the introduction of fractional base units is believed to be a major step towards the implementation of the KMD analysis as a routine data mining tool for mass spectrometry in polymer chemistry.Keywords
This publication has 29 references indexed in Scilit:
- Multidimensional Mass Spectrometry of Synthetic Polymers and Advanced MaterialsAngewandte Chemie International Edition, 2017
- Structural characterization of silicone polymers using compositional ultra-high performance liquid chromatography separation, electrospray ionization, and high resolution/accurate massAnalytica Chimica Acta, 2014
- MALDI of synthetic polymers with labile end‐groupsMass Spectrometry Reviews, 2013
- Capabilities and limitations of direct analysis in real time orbitrap mass spectrometry and tandem mass spectrometry for the analysis of synthetic and natural polymersRapid Communications in Mass Spectrometry, 2013
- High Resolution Mass SpectrometryAnalytical Chemistry, 2012
- Mass Spectrometry of Polymers – New Techniques2012
- Mass spectrometry in polymer chemistry: a state-of-the-art up-datePolymer Chemistry, 2010
- Influence of internal standard charge state on the accuracy of mass measurements in orthogonal acceleration time‐of‐flight mass spectrometersRapid Communications in Mass Spectrometry, 2007
- The design and characteristic features of a new time-of-flight mass spectrometer with a spiral ion trajectoryJournal of the American Society for Mass Spectrometry, 2005
- Mass Spectrometry of Polymers2001