Multi-angle pulse shape detection of scattered light in flow cytometry for label-free cell cycle classification
Open Access
- 30 September 2021
- journal article
- research article
- Published by Springer Nature in Communications Biology
- Vol. 4 (1) , 1-11
Abstract
Flow cytometers are robust and ubiquitous tools of biomedical research, as they enable high-throughput fluorescence-based multi-parametric analysis and sorting of single cells. However, analysis is often constrained by the availability of detection reagents or functional changes of cells caused by fluorescent staining. Here, we introduce MAPS-FC (multi-angle pulse shape flow cytometry), an approach that measures angle- and time-resolved scattered light for high-throughput cell characterization to circumvent the constraints of conventional flow cytometry. In order to derive cell-specific properties from the acquired pulse shapes, we developed a data analysis procedure based on wavelet transform and k-means clustering. We analyzed cell cycle stages of Jurkat and HEK293 cells by MAPS-FC and were able to assign cells to the G1, S, and G2/M phases without the need for fluorescent labeling. The results were validated by DNA staining and by sorting and re-analysis of isolated G1, S, and G2/M populations. Our results demonstrate that MAPS-FC can be used to determine cell properties that are otherwise only accessible by invasive labeling. This approach is technically compatible with conventional flow cytometers and paves the way for label-free cell sorting.Keywords
This publication has 42 references indexed in Scilit:
- Tracking protein aggregation and mislocalization in cells with flow cytometryNature Methods, 2012
- Functional analysis and classification of phytoplankton based on data from an automated flow cytometerCytometry Part A, 2011
- Measurement and autocorrelation analysis of two‐dimensional light‐scattering patterns from living cells for label‐free classificationCytometry Part A, 2011
- Quantification of nanoscale nuclear refractive index changes during the cell cycleJournal of Biomedical Optics, 2011
- Light scattering and morphology of the lymphocyte as applied to flow cytometry for distinguishing healthy and infected individualsJournal of Biomedical Optics, 2010
- Cell Cycle Synchronization at the G2/M Phase Border by Reversible Inhibition of CDK1Cell Cycle, 2006
- The mutagenic properties of DNA minor-groove binding ligandsMutation Research - Fundamental and Molecular Mechanisms of Mutagenesis, 1996
- Flow cytometric analysis using digital signal processingCytometry, 1995
- Chromosome banding analysis by slit‐scan flow cytometryCytometry, 1989
- Cytotoxicity, Mutagenicity and DNA damage by Hoechst 33342.Journal of Histochemistry & Cytochemistry, 1982