Toralf Kaiser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Toralf Kaiser has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Jenny Kirsch
German Rheumatology Research Center (DRFZ) - Flow Cytometry Core Facility, Berlin, Germany
9 shared publicationsAndreas Radbruch
Department of Cell Biology Deutsches Rheuma‐Forschungzentrum Berlin, ein Institut der Leibniz Gesellschaft Berlin Germany
6 shared publicationsKristen Feher
EMBL Australia Node in Single Molecule Science, School of Medical Sciences, University of New South Wales, Sydney, Australia
6 shared publicationsDaniel Kage
Flow Cytometry Core Facility Deutsches Rheuma‐Forschungszentrumein Institut der Leibniz‐Gemeinschaft Berlin Germany
5 shared publications- Elena A. Levashina
Vector Biology Unit, Max Planck Institute for Infection Biology, Berlin, Germany
5 shared publications Konrad von Volkmann
APE Angewandte Physik und Elektronik GmbH Berlin Germany
5 shared publications
Latest Publications
- Open Access
- 5 November 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (11) , e0354060
Identification of Plasmodium sporozoites using angle-resolved scattered light pulse shapes
Flow cytometry is widely used to identify and sort rare cells, but conventional approaches rely on fluorescent labels. Label-free discrimination of rare targets in complex, heterogeneous samples remains challenging. Here, we introduce a label-free strategy that combines multi-angle pulse shape flow cytometry (MAPS-FC), which exploits the full temporal structure of the signal pulses during cell or particles transit through the laser spot, with a deep learning–based analysis. As a biologically relevant test case, we focus on Plasmodium falciparum sporozoites, the infectious stage of the malaria parasite, which need to be isolated from mosquito salivary glands and are embedded in a heterogeneous mosquito-derived background. Using a GFP-expressing reporter line for validation, we trained a long short-term memory (LSTM) neural network to classify sporozoites solely from their scattering pulse shapes captured through MAPS-FC. Using training data from multiple days and setting a threshold on the classification confidence, the network can distinguish sporozoites from mosquito debris without fluorescent labels. This work establishes MAPS-FC with deep learning as a platform for label-free identification of rare parasites in complex biological samples.
- 5 November 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (11) , e0354060
Open AccessIdentification of Plasmodium sporozoites using angle-resolved scattered light pulse shapes
Flow cytometry is widely used to identify and sort rare cells, but conventional approaches rely on fluorescent labels. Label-free discrimination of rare targets in complex, heterogeneous samples remains challenging. Here, we introduce a label-free strategy that combines multi-angle pulse shape flow cytometry (MAPS-FC), which exploits the full temporal structure of the signal pulses during cell or particles transit through the laser spot, with a deep learning–based analysis. As a biologically relevant test case, we focus on Plasmodium falciparum sporozoites, the infectious stage of the malaria parasite, which need to be isolated from mosquito salivary glands and are embedded in a heterogeneous mosquito-derived background. Using a GFP-expressing reporter line for validation, we trained a long short-term memory (LSTM) neural network to classify sporozoites solely from their scattering pulse shapes captured through MAPS-FC. Using training data from multiple days and setting a threshold on the classification confidence, the network can distinguish sporozoites from mosquito debris without fluorescent labels. This work establishes MAPS-FC with deep learning as a platform for label-free identification of rare parasites in complex biological samples.
- Open Access
- 18 August 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (24) , 7154-7167
Pulse shapes of angle- and time-resolved scattering and interference signals in a flow cytometer
Particles passing through a focused laser beam in a flow cytometer cause time-dependent angular intensity distributions of the scattered light, which can be detected as signal pulses of a few microseconds in length. Extinction effects are observed due to interference between the incident beam and scattered light near the forward direction. We present angle-resolved measurements of such pulses for polymer microparticles using an optical fiber array. Even for homogeneous spherical particles, this can result in pulses with non-trivial shapes that carry information about the particles. We compare with results from mathematical modeling based on generalized Lorenz–Mie theory for the scattering of elliptical Gaussian beams by spherical particles at arbitrary locations.
- 18 August 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (24) , 7154-7167
Open AccessPulse shapes of angle- and time-resolved scattering and interference signals in a flow cytometer
Particles passing through a focused laser beam in a flow cytometer cause time-dependent angular intensity distributions of the scattered light, which can be detected as signal pulses of a few microseconds in length. Extinction effects are observed due to interference between the incident beam and scattered light near the forward direction. We present angle-resolved measurements of such pulses for polymer microparticles using an optical fiber array. Even for homogeneous spherical particles, this can result in pulses with non-trivial shapes that carry information about the particles. We compare with results from mathematical modeling based on generalized Lorenz–Mie theory for the scattering of elliptical Gaussian beams by spherical particles at arbitrary locations.
- Open Access
- 30 August 2024
- Published by Springer Nature in Communications Biology
- Vol. 7 (1) , 1-11
Cell sorting based on pulse shapes from angle resolved detection of scattered light
Flow cytometry is a key technology for the analysis and sorting of cells or particles at high throughput. Conventional and current flow cytometry is primarily based on fluorescent stains to detect the cells of interest. However, such stains also have disadvantages, as their effect on cells must be carefully tested to avoid effects on the results of the experiments. Alternative approaches using imaging or other label-free techniques often require highly sophisticated setups, are commonly limited in resolution, and produce challenging amounts of data. Our technology exploits scattered light instead. The custom-built flow cytometry setup comprises a fiber array in forward scatter detection for angular resolution and captures the whole pulse shape with advanced signal processing. Thereby this setup enables cell analysis and sorting purely based on scattered light signals without the need for fluorescent labels. We demonstrate the feasibility of this cell sorting technology by sorting cell lines for their cell cycle stages based on scattered light. Furthermore, we demonstrate the ability to classify human peripheral blood T- and B-cell subsets.
- 30 August 2024
- Published by Springer Nature in Communications Biology
- Vol. 7 (1) , 1-11
Open AccessCell sorting based on pulse shapes from angle resolved detection of scattered light
Flow cytometry is a key technology for the analysis and sorting of cells or particles at high throughput. Conventional and current flow cytometry is primarily based on fluorescent stains to detect the cells of interest. However, such stains also have disadvantages, as their effect on cells must be carefully tested to avoid effects on the results of the experiments. Alternative approaches using imaging or other label-free techniques often require highly sophisticated setups, are commonly limited in resolution, and produce challenging amounts of data. Our technology exploits scattered light instead. The custom-built flow cytometry setup comprises a fiber array in forward scatter detection for angular resolution and captures the whole pulse shape with advanced signal processing. Thereby this setup enables cell analysis and sorting purely based on scattered light signals without the need for fluorescent labels. We demonstrate the feasibility of this cell sorting technology by sorting cell lines for their cell cycle stages based on scattered light. Furthermore, we demonstrate the ability to classify human peripheral blood T- and B-cell subsets.
- Open Access
- 8 July 2022
- Published by Wiley in Engineering in Life Sciences
- Vol. 22 (8) , 550-553
A UV‐C LED‐based unit for continuous decontamination of the sheath fluid in a flow‐cytometric cell sorter
Aseptic cell sorting is challenging, especially when a flow-cytometric cell sorter is not operated in a sterile environment. The sheath fluid system of a cell sorter may be contaminated with germs such as bacteria, yeasts, viruses, or fungi. Thus, a regular chemical cleaning procedure is required to prepare a sorter for aseptic cell sorting by flushing the fluidic system. However, this procedure is time consuming, and most importantly, the researcher can never be sure that the cleaning process was successful. Here we present a method in which the sheath fluid of a cell sorter was decontaminated by irradiation with UV-C light using a flow-through principle. Using this principle, we were able to achieve a 5 log reduction of bacteria in the sheath fluid.
- 8 July 2022
- Published by Wiley in Engineering in Life Sciences
- Vol. 22 (8) , 550-553
Open AccessA UV‐C LED‐based unit for continuous decontamination of the sheath fluid in a flow‐cytometric cell sorter
Aseptic cell sorting is challenging, especially when a flow-cytometric cell sorter is not operated in a sterile environment. The sheath fluid system of a cell sorter may be contaminated with germs such as bacteria, yeasts, viruses, or fungi. Thus, a regular chemical cleaning procedure is required to prepare a sorter for aseptic cell sorting by flushing the fluidic system. However, this procedure is time consuming, and most importantly, the researcher can never be sure that the cleaning process was successful. Here we present a method in which the sheath fluid of a cell sorter was decontaminated by irradiation with UV-C light using a flow-through principle. Using this principle, we were able to achieve a 5 log reduction of bacteria in the sheath fluid.
- Open Access
- 30 September 2021
- Published by Springer Nature in Communications Biology
- Vol. 4 (1) , 1-11
Multi-angle pulse shape detection of scattered light in flow cytometry for label-free cell cycle classification
Flow cytometers are robust and ubiquitous tools of biomedical research, as they enable high-throughput fluorescence-based multi-parametric analysis and sorting of single cells. However, analysis is often constrained by the availability of detection reagents or functional changes of cells caused by fluorescent staining. Here, we introduce MAPS-FC (multi-angle pulse shape flow cytometry), an approach that measures angle- and time-resolved scattered light for high-throughput cell characterization to circumvent the constraints of conventional flow cytometry. In order to derive cell-specific properties from the acquired pulse shapes, we developed a data analysis procedure based on wavelet transform and k-means clustering. We analyzed cell cycle stages of Jurkat and HEK293 cells by MAPS-FC and were able to assign cells to the G1, S, and G2/M phases without the need for fluorescent labeling. The results were validated by DNA staining and by sorting and re-analysis of isolated G1, S, and G2/M populations. Our results demonstrate that MAPS-FC can be used to determine cell properties that are otherwise only accessible by invasive labeling. This approach is technically compatible with conventional flow cytometers and paves the way for label-free cell sorting.
- 30 September 2021
- Published by Springer Nature in Communications Biology
- Vol. 4 (1) , 1-11
Open AccessMulti-angle pulse shape detection of scattered light in flow cytometry for label-free cell cycle classification
Flow cytometers are robust and ubiquitous tools of biomedical research, as they enable high-throughput fluorescence-based multi-parametric analysis and sorting of single cells. However, analysis is often constrained by the availability of detection reagents or functional changes of cells caused by fluorescent staining. Here, we introduce MAPS-FC (multi-angle pulse shape flow cytometry), an approach that measures angle- and time-resolved scattered light for high-throughput cell characterization to circumvent the constraints of conventional flow cytometry. In order to derive cell-specific properties from the acquired pulse shapes, we developed a data analysis procedure based on wavelet transform and k-means clustering. We analyzed cell cycle stages of Jurkat and HEK293 cells by MAPS-FC and were able to assign cells to the G1, S, and G2/M phases without the need for fluorescent labeling. The results were validated by DNA staining and by sorting and re-analysis of isolated G1, S, and G2/M populations. Our results demonstrate that MAPS-FC can be used to determine cell properties that are otherwise only accessible by invasive labeling. This approach is technically compatible with conventional flow cytometers and paves the way for label-free cell sorting.
- Open Access
- 14 August 2020
- Published by Wiley in Cytometry Part A
- Vol. 97 (12) , 1278
Response to Parks et al.: Multispectral Flow Cytometry: Unaddressed Issues and Recommendations for Improvement
- 14 August 2020
- Published by Wiley in Cytometry Part A
- Vol. 97 (12) , 1278
Open AccessResponse to Parks et al.: Multispectral Flow Cytometry: Unaddressed Issues and Recommendations for Improvement
- Open Access
- 1 April 2020
- Published by Wiley in Cytometry Part A
- Vol. 97 (4) , 429-430
Response to: Comments on the publication "Determination of Background, Signal-to-Noise, and Dynamic Range of a Flow Cytometer: A Novel Practical Method for Instrument Characterization and Standardization" by Giesecke et al.
- 1 April 2020
- Published by Wiley in Cytometry Part A
- Vol. 97 (4) , 429-430
Open AccessResponse to: Comments on the publication "Determination of Background, Signal-to-Noise, and Dynamic Range of a Flow Cytometer: A Novel Practical Method for Instrument Characterization and Standardization" by Giesecke et al.
- Open Access
- 14 May 2019
- Published by Wiley in Cytometry Part A
- Vol. 95 (7) , 803-804
Corrigendum: Multispectral Flow Cytometry: The Consequences of Increased Light Collection
- 14 May 2019
- Published by Wiley in Cytometry Part A
- Vol. 95 (7) , 803-804
Open AccessCorrigendum: Multispectral Flow Cytometry: The Consequences of Increased Light Collection
- 30 September 2017
- Published by Springer Nature in BIOspektrum
- Vol. 23 (6) , 658-661
Neue Spektren in der Durchflusszytometrie
- 30 September 2017
- Published by Springer Nature in BIOspektrum
- Vol. 23 (6) , 658-661
Neue Spektren in der Durchflusszytometrie
- 27 September 2017
- Published by Wiley in Cytometry Part A
- Vol. 91 (11) , 1104-1114
Determination of background, signal‐to‐noise, and dynamic range of a flow cytometer: A novel practical method for instrument characterization and standardization
A well‐defined scale calibration in flow cytometry can improve many aspects of data acquisition such as cytometer setup, instrument comparison and sample comparison. The theory for scale calibration was proposed by Steen over two decades ago, but it has never been put into regular use due to the lack of a widely available precision light source. The introduction of such a light source, the quantiFlashTM , gave this possibility. Here, we describe how this light source can be used to characterize a cytometer's PMT performance. We, therefore, characterized the instrument's response over the entire PMT voltage range. As a consequence, we propose a practical method to characterize a cytometer's signal‐to‐noise ratio (SNR) and dynamic range (DNR). This allows the selection of a voltage/gain corresponding to a PMT's maximum efficiency and hence the lowest electronic noise, which can help with experiment design. We further introduced a decibel (dB) scale for the presentation of SNR and DNR values. SNR and DNR are stand‐alone values that allow the direct comparison of different instruments. Finally, with this method, it becomes clear that increased SNR comes at the expense of DNR and thus the limiting factor of modern cytometers is the DNR. © 2017 International Society for Advancement of Cytometry
- 27 September 2017
- Published by Wiley in Cytometry Part A
- Vol. 91 (11) , 1104-1114
Determination of background, signal‐to‐noise, and dynamic range of a flow cytometer: A novel practical method for instrument characterization and standardization
A well‐defined scale calibration in flow cytometry can improve many aspects of data acquisition such as cytometer setup, instrument comparison and sample comparison. The theory for scale calibration was proposed by Steen over two decades ago, but it has never been put into regular use due to the lack of a widely available precision light source. The introduction of such a light source, the quantiFlashTM , gave this possibility. Here, we describe how this light source can be used to characterize a cytometer's PMT performance. We, therefore, characterized the instrument's response over the entire PMT voltage range. As a consequence, we propose a practical method to characterize a cytometer's signal‐to‐noise ratio (SNR) and dynamic range (DNR). This allows the selection of a voltage/gain corresponding to a PMT's maximum efficiency and hence the lowest electronic noise, which can help with experiment design. We further introduced a decibel (dB) scale for the presentation of SNR and DNR values. SNR and DNR are stand‐alone values that allow the direct comparison of different instruments. Finally, with this method, it becomes clear that increased SNR comes at the expense of DNR and thus the limiting factor of modern cytometers is the DNR. © 2017 International Society for Advancement of Cytometry