Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems
Open Access
- 26 February 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 141-153
Abstract
The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system’s frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.Keywords
Funding Information
- National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, under U.S. Department of Energy (DE-AC36-08GO28308)
- U.S. Department of Energy Office of Energy Efficiency and Renewable Energy, Solar Energy Technologies Office (34224, 37772)
This publication has 38 references indexed in Scilit:
- Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables2023
- Robust frequency constrained uc using data driven logistic regression for island power systemsIET Generation, Transmission & Distribution, 2022
- A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems2022
- Prediction of new active cases of coronavirus disease (COVID-19) pandemic using multiple linear regression modelDiabetes & Metabolic Syndrome: Clinical Research & Reviews, 2020
- Frequency‐constrained unit‐commitment using analytical solutions for system frequency responses considering generator contingenciesIET Generation, Transmission & Distribution, 2020
- Data-Driven Look-Ahead Unit Commitment Considering Forbidden Zones and Dynamic Ramping RatesIEEE Transactions on Industrial Informatics, 2018
- Predictive and mechanistic multivariate linear regression models for reaction developmentChemical Science, 2018
- A Frequency-Constrained Stochastic Economic Dispatch ModelIEEE Transactions on Power Systems, 2013
- Frequency-regulating reserve constrained unit commitment for an isolated power systemIEEE Transactions on Power Systems, 2012
- Adaptive Underfrequency Load Shedding Based on the Magnitude of the Disturbance EstimationIEEE Transactions on Power Systems, 2006