Ningchao Gao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Xin Fang
National Key Laboratory of Equipment State Sensing and Smart Support, College of Intelligent Science and Technology, National University of Defense Technology, Changsha, China
4 shared publications - Jin Tan
National Laboratory of the Rockies (NLR), Golden, CO (United States)
3 shared publications - Yuxin Deng
Department of Electrical and Computer Engineering, Mississippi State University, Starkville, MS, USA
2 shared publications - Andy Hoke
National Laboratory of the Rockies (NLR), Golden, CO (United States)
1 shared publication - David Wenzhong Gao
Department of Electrical and Computer Engineering, University of Denver, Denver, CO, USA
1 shared publication Haoyu Yuan
Active Power Investments LLC, Bellaire, TX, USA
1 shared publication
Latest Publications
- Open Access
- 30 March 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 258
Analytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation
- 30 March 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 258
Open AccessAnalytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation
- Open Access
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 595-609
Multi-Timescale Modeling Framework of Hybrid Power Plants Providing Secondary Frequency Regulation
Hybrid power plants (HPPs) present a promising solution to address the significant challenges posed by the rapid integration of variable renewable energy sources (VREs) into power systems, particularly in maintaining power balance and frequency stability. Therefore, there is a pressing need for system operators and HPP owners to effectively manage both the energy and regulation services of HPPs within the current system operational framework. Existing studies on HPP modeling often separate dynamic control from steady-state scheduling and lack coordinated integration of self-scheduling of HPPs with the system-level scheduling, leading to over/under estimation of the flexibility of HPPs. To address this challenge, this paper presents a generic modeling framework for HPPs that integrates steady-state optimization with dynamic control across multiple timescales, enabling seamless HPP participation in day-ahead and real-time markets and real-time control. Additionally, the framework facilitates comprehensive economic and frequency performance evaluations. Case studies on a modified IEEE 39-bus system demonstrate the framework’s ability to ensure frequency performance with flexible HPP operation modes, align BESS state-of-charge (SOC) with dispatch targets, and optimize reliability and economic outcomes under various scenarios.
- 22 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 595-609
Open AccessMulti-Timescale Modeling Framework of Hybrid Power Plants Providing Secondary Frequency Regulation
Hybrid power plants (HPPs) present a promising solution to address the significant challenges posed by the rapid integration of variable renewable energy sources (VREs) into power systems, particularly in maintaining power balance and frequency stability. Therefore, there is a pressing need for system operators and HPP owners to effectively manage both the energy and regulation services of HPPs within the current system operational framework. Existing studies on HPP modeling often separate dynamic control from steady-state scheduling and lack coordinated integration of self-scheduling of HPPs with the system-level scheduling, leading to over/under estimation of the flexibility of HPPs. To address this challenge, this paper presents a generic modeling framework for HPPs that integrates steady-state optimization with dynamic control across multiple timescales, enabling seamless HPP participation in day-ahead and real-time markets and real-time control. Additionally, the framework facilitates comprehensive economic and frequency performance evaluations. Case studies on a modified IEEE 39-bus system demonstrate the framework’s ability to ensure frequency performance with flexible HPP operation modes, align BESS state-of-charge (SOC) with dispatch targets, and optimize reliability and economic outcomes under various scenarios.
- Open Access
- 26 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 141-153
Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems
The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system’s frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.
- 26 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 11, 141-153
Open AccessFrequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems
The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system’s frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.
- 28 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (6) , 5278-5289
Manage Real-Time Power Imbalance With Renewable Energy: Fast Generation Dispatch or Adaptive Frequency Regulation?
The carbon neutrality objective requires a large amount of renewable energy integrated into power systems. The rapid deployment of variable renewable energy (VRE), such as solar photovoltaic (PV) generation, increases the system real-time power imbalance because of the random variation and uncertainty of VRE power generation. To manage this, system operators have two potential options: the first is a fast real-time generation dispatch to schedule generation resources with a small time interval to promptly follow the change of load and renewable power. The second is to procure adaptive frequency regulation services, such as secondary frequency regulation (SFR), based on the system variation and imbalance conditions to reduce the power imbalance and maintain the stable intra-interval frequency. This paper proposes an integrated alternating current optimal power flow-based generation scheduling and time domain simulation framework to investigate the economic and reliability perspectives of aforementioned two options. The impacts of the SFR requirements on the generation cost and frequency response performance are analyzed. In addition, the SFR provided by the PV generation is investigated. The uncertainty of the PV power output is considered using chance constraints to guarantee the real-time delivery of its frequency regulation services. The framework is tested in the IEEE 39-bus network with a large-scale PV power plant. The simulation results demonstrate that the small real-time generation dispatch interval does not necessarily improve the system frequency response and cannot maintain stable frequency. An adaptive frequency regulation with a 5-minute economic dispatch interval is more appropriate and efficient to reduce the generation cost and improve the frequency response with renewable energy.
- 28 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (6) , 5278-5289
Manage Real-Time Power Imbalance With Renewable Energy: Fast Generation Dispatch or Adaptive Frequency Regulation?
The carbon neutrality objective requires a large amount of renewable energy integrated into power systems. The rapid deployment of variable renewable energy (VRE), such as solar photovoltaic (PV) generation, increases the system real-time power imbalance because of the random variation and uncertainty of VRE power generation. To manage this, system operators have two potential options: the first is a fast real-time generation dispatch to schedule generation resources with a small time interval to promptly follow the change of load and renewable power. The second is to procure adaptive frequency regulation services, such as secondary frequency regulation (SFR), based on the system variation and imbalance conditions to reduce the power imbalance and maintain the stable intra-interval frequency. This paper proposes an integrated alternating current optimal power flow-based generation scheduling and time domain simulation framework to investigate the economic and reliability perspectives of aforementioned two options. The impacts of the SFR requirements on the generation cost and frequency response performance are analyzed. In addition, the SFR provided by the PV generation is investigated. The uncertainty of the PV power output is considered using chance constraints to guarantee the real-time delivery of its frequency regulation services. The framework is tested in the IEEE 39-bus network with a large-scale PV power plant. The simulation results demonstrate that the small real-time generation dispatch interval does not necessarily improve the system frequency response and cannot maintain stable frequency. An adaptive frequency regulation with a 5-minute economic dispatch interval is more appropriate and efficient to reduce the generation cost and improve the frequency response with renewable energy.