The Xe44+ 2.7203 Å line, which has been proposed as one of the diagnostic lines for the x-ray imaging crystal spectrometer on ITER, is observed on the EAST tokamak together with its several satellite lines. The observations are made under high electron temperature (T e ) conditions (core T e > 5 keV). Most of the observed xenon lines are identified by comparing the experiment results with the atomic simulation results. The first ion temperature measurements made by the xenon spectra on EAST are also reported in this article. These xenon spectra observations contribute to the justification for using xenon as the diagnostic impurity in x-ray crystal spectrometers in future reactor-scale high-temperature plasmas.Keywords
Funding Information
- National Natural Science Foundation of China (12175278)
- Open Fund of Magnetic Confinement Fusion Laboratory of Anhui Province (2021AMF01002)
- The University Synergy Innovation Program of Anhui Province (GXXT-2021-029)
- Comprehensive Research Facility for Fusion Technology Program of China (2018-000052-73-01-001228)
- National Magnetic Confinement Fusion Science Program of China (2018-000052-73-01-001228)
- Natural Science Foundation of Anhui Province (1908085J01)
This publication has 24 references indexed in Scilit:
- Spatially Resolved Measurements of Temperature and Rotation Velocity from the Tangential Imaging X-ray Crystal Spectrometer on the EAST TokamakJournal of the Korean Physical Society, 2011
- Upgraded multipulse laser and multipoint Thomson scattering diagnostics on EASTReview of Scientific Instruments, 2011
- Development of a spatially resolving x-ray crystal spectrometer for measurement of ion-temperature (Ti) and rotation-velocity (v) profiles in ITERReview of Scientific Instruments, 2010
- Imaging x-ray crystal spectrometer on EASTPlasma Physics and Controlled Fusion, 2010
- The ITER core imaging x-ray spectrometerJournal of Physics B: Atomic, Molecular and Optical Physics, 2010
- Spatially resolved high resolution x-ray spectroscopy for magnetically confined fusion plasmas (invited)Review of Scientific Instruments, 2008
- The flexible atomic codeCanadian Journal of Physics, 2008
- FLYCHK: Generalized population kinetics and spectral model for rapid spectroscopic analysis for all elementsHigh Energy Density Physics, 2005
- Inversion technique to obtain an emissivity profile from tangential line-integrated hard x-ray measurementsReview of Scientific Instruments, 1995
- X-ray transitions in highly charged neonlike ionsPhysical Review A, 1988