Dian Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dian Lu has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Bo Lyu
Institute of Plasma Physics, Chinese Academy of Sciences
4 shared publications - Fudi Wang
Institute of Plasma Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China
3 shared publications - Hongming Zhang
Institute of Plasma Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China
3 shared publications - Jia Fu
Institute of Plasma Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China
3 shared publications - Lan Gao
Princeton Plasma Physics Laboratory, Princeton University 1 , Princeton, New Jersey 08543
3 shared publications - Novimir Antoniuk Pablant
Princeton Plasma Physics Laboratory
3 shared publications
Latest Publications
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Advanced Simulation of ITER Core X-ray Crystal Spectroscopy
X-Ray Simulation Analysis (XRSA) is an analytical ray-tracing mixed code developed specifically for the ITER Core X-Ray Crystal Spectroscopy (XRCS-Core) diagnostic, which employs a dual-reflection configuration incorporating multiple pre-reflectors made of Highly Oriented Pyrolytic Graphite (HOPG) and spherically curved analyzing crystals. The ITER XRCS-Core is designed for high spectral resolution measurement in specific wavelength ranges, including narrow bands around 1.354 Å for W64+, 2.19 Å for Xe51+, and 2.555 Å for Xe44+ and Xe47+, enabling diagnostic capability across a broad electron temperature range in the ITER plasma. XRSA facilitates efficient simulation of the spectral performance of this complex X-ray spectroscopic system. Recent updates to the XRSA code have incorporated two critical effects: auto-focusing, which specifically applies to HOPG, and polarization. These two effects are particularly important in the dual-reflection configuration used in the ITER XRCS-Core system to provide more accurate modeling results. Simulations conducted with the updated code demonstrate that polarization has a substantial impact on the performance of the dual-reflection system. Additionally, the combined influence of polarization and system layout introduces performance variations across channels through the same crystal.
- 1 May 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (5)
Advanced Simulation of ITER Core X-ray Crystal Spectroscopy
X-Ray Simulation Analysis (XRSA) is an analytical ray-tracing mixed code developed specifically for the ITER Core X-Ray Crystal Spectroscopy (XRCS-Core) diagnostic, which employs a dual-reflection configuration incorporating multiple pre-reflectors made of Highly Oriented Pyrolytic Graphite (HOPG) and spherically curved analyzing crystals. The ITER XRCS-Core is designed for high spectral resolution measurement in specific wavelength ranges, including narrow bands around 1.354 Å for W64+, 2.19 Å for Xe51+, and 2.555 Å for Xe44+ and Xe47+, enabling diagnostic capability across a broad electron temperature range in the ITER plasma. XRSA facilitates efficient simulation of the spectral performance of this complex X-ray spectroscopic system. Recent updates to the XRSA code have incorporated two critical effects: auto-focusing, which specifically applies to HOPG, and polarization. These two effects are particularly important in the dual-reflection configuration used in the ITER XRCS-Core system to provide more accurate modeling results. Simulations conducted with the updated code demonstrate that polarization has a substantial impact on the performance of the dual-reflection system. Additionally, the combined influence of polarization and system layout introduces performance variations across channels through the same crystal.
- 1 January 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (1)
Performance characterization of x-ray crystal spectroscopy highly oriented pyrolytic graphite reflectors based on x-ray diffractometry experiments
The use of Highly Oriented Pyrolytic Graphite (HOPG) reflectors is often proposed in the design of X-ray Crystal Spectroscopy (XCS) diagnostic systems for the next-generation tokamak devices, including the ITER project. This study introduces an experimental study based on the X-Ray Diffractometry (XRD) method to evaluate the performance of HOPG reflectors. The experimental method provides both the angular responses and the reflectivities of the HOPG reflectors. A demonstrative XRD experiment is conducted, and the details of the experiment are introduced. This method enables precise studies on HOPG reflectors, facilitating the design of XCS diagnostic systems for future tokamaks.
- 1 January 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (1)
Performance characterization of x-ray crystal spectroscopy highly oriented pyrolytic graphite reflectors based on x-ray diffractometry experiments
The use of Highly Oriented Pyrolytic Graphite (HOPG) reflectors is often proposed in the design of X-ray Crystal Spectroscopy (XCS) diagnostic systems for the next-generation tokamak devices, including the ITER project. This study introduces an experimental study based on the X-Ray Diffractometry (XRD) method to evaluate the performance of HOPG reflectors. The experimental method provides both the angular responses and the reflectivities of the HOPG reflectors. A demonstrative XRD experiment is conducted, and the details of the experiment are introduced. This method enables precise studies on HOPG reflectors, facilitating the design of XCS diagnostic systems for future tokamaks.
- Open Access
- 13 September 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (10) , 106061
Prediction of plasma rotation velocity and ion temperature profiles in EAST Tokamak using artificial neural network models
Artificial neural network models have been developed to predict rotation velocity and ion temperature profiles on the EAST tokamak based on spectral measurements from the x-ray crystal spectrometer. Both Deep Neural Network (DNN) and Convolutional Neural Network (CNN) models have been employed to infer line-integrated ion temperatures. The predicted results from these two models exhibit a strong correlation with the target values, providing an opportunity for cross-validation to enhance prediction accuracy. Notably, the computational speed of these models has been significantly increased, surpassing traditional methods by over tenfold. Furthermore, the investigation of input data range and error prediction serves as the foundation for future automated calculation process. Finally, CNNs have also been employed to predict line-integrated rotation velocity profiles and inverted ion temperature profiles for their robustness in the training process. It is noted that these algorithms are not restricted to any specific physics model and can be readily adapted to various fusion devices.
- 13 September 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (10) , 106061
Open AccessPrediction of plasma rotation velocity and ion temperature profiles in EAST Tokamak using artificial neural network models
Artificial neural network models have been developed to predict rotation velocity and ion temperature profiles on the EAST tokamak based on spectral measurements from the x-ray crystal spectrometer. Both Deep Neural Network (DNN) and Convolutional Neural Network (CNN) models have been employed to infer line-integrated ion temperatures. The predicted results from these two models exhibit a strong correlation with the target values, providing an opportunity for cross-validation to enhance prediction accuracy. Notably, the computational speed of these models has been significantly increased, surpassing traditional methods by over tenfold. Furthermore, the investigation of input data range and error prediction serves as the foundation for future automated calculation process. Finally, CNNs have also been employed to predict line-integrated rotation velocity profiles and inverted ion temperature profiles for their robustness in the training process. It is noted that these algorithms are not restricted to any specific physics model and can be readily adapted to various fusion devices.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing
A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe44+, Xe47+, and Xe51+, based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing
A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe44+, Xe47+, and Xe51+, based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.
- Open Access
- 21 February 2023
- Published by IOP Publishing in Nuclear Fusion
- Vol. 63 (5) , 056002
Observations of xenon spectra on the EAST x-ray crystal spectrometer for high-temperature plasma diagnostics
The Xe44+ 2.7203 Å line, which has been proposed as one of the diagnostic lines for the x-ray imaging crystal spectrometer on ITER, is observed on the EAST tokamak together with its several satellite lines. The observations are made under high electron temperature (T e ) conditions (core T e > 5 keV). Most of the observed xenon lines are identified by comparing the experiment results with the atomic simulation results. The first ion temperature measurements made by the xenon spectra on EAST are also reported in this article. These xenon spectra observations contribute to the justification for using xenon as the diagnostic impurity in x-ray crystal spectrometers in future reactor-scale high-temperature plasmas.
- 21 February 2023
- Published by IOP Publishing in Nuclear Fusion
- Vol. 63 (5) , 056002
Open AccessObservations of xenon spectra on the EAST x-ray crystal spectrometer for high-temperature plasma diagnostics
The Xe44+ 2.7203 Å line, which has been proposed as one of the diagnostic lines for the x-ray imaging crystal spectrometer on ITER, is observed on the EAST tokamak together with its several satellite lines. The observations are made under high electron temperature (T e ) conditions (core T e > 5 keV). Most of the observed xenon lines are identified by comparing the experiment results with the atomic simulation results. The first ion temperature measurements made by the xenon spectra on EAST are also reported in this article. These xenon spectra observations contribute to the justification for using xenon as the diagnostic impurity in x-ray crystal spectrometers in future reactor-scale high-temperature plasmas.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043544
Design consideration of an x-ray imaging crystal spectrometer for China Fusion Engineering Test Reactor
The x-ray imaging crystal spectrometer (XICS) is proposed as the principal method of diagnostics for plasma ion temperature and rotation for the China Fusion Engineering Test Reactor (CFETR) for its simplicity in implementation and no reliance on neutral beams. For D–T experiments with the electron temperature as high as 35–40 keV at the core region, highly charged high-Z ions can serve as the diagnostic ions for the XICS. For the CFETR, Xe44+, Xe51+, and W64+ are selected as the impurity ions. Appropriate crystal parameters are selected, as well as the preliminary layout for the spectrometer. We estimated the general performance of the spectrometer, including the emissivity of the impurities, the spatial resolution of the x-ray detector, and the expected count rate of line emissions. For the application in the fusion reactor environment, the effect of neutron irradiation on the crystal is briefly discussed.
- 1 April 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (4) , 043544
Design consideration of an x-ray imaging crystal spectrometer for China Fusion Engineering Test Reactor
The x-ray imaging crystal spectrometer (XICS) is proposed as the principal method of diagnostics for plasma ion temperature and rotation for the China Fusion Engineering Test Reactor (CFETR) for its simplicity in implementation and no reliance on neutral beams. For D–T experiments with the electron temperature as high as 35–40 keV at the core region, highly charged high-Z ions can serve as the diagnostic ions for the XICS. For the CFETR, Xe44+, Xe51+, and W64+ are selected as the impurity ions. Appropriate crystal parameters are selected, as well as the preliminary layout for the spectrometer. We estimated the general performance of the spectrometer, including the emissivity of the impurities, the spatial resolution of the x-ray detector, and the expected count rate of line emissions. For the application in the fusion reactor environment, the effect of neutron irradiation on the crystal is briefly discussed.