Evaluation of Single-Photon Emission Computed Tomography Myocardial Perfusion Detection Capability through Physical Descriptors
Open Access
- 18 June 2024
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 14 (12) , 5283
Abstract
A comprehensive validation of data acquired by different myocardial perfusion imaging (MPI) systems was performed to evaluate contrast, self-attenuation properties, and perfusion detection capability. An anthropomorphic phantom with a myocardial insert and perfusion defect was used to simulate 99mTc-tetrofosmin distribution. Different MPI systems were evaluated: a SPECT system with iterative reconstruction algorithms and resolution recovery (IRR) with/without scatter correction (SPECT-IRR-SC and SPECT-IRR), and a cardio-centric IQ SPECT/CT system with IRR, with/without scatter and attenuation corrections (IQ-IRR-SC-AC and IQ-IRR). The image quality was assessed through physical descriptors: the contrast between the left ventricular (LV) wall and LV inner chamber (), intrinsic contrast (IC), and net contrast (NC). was found to be superior for IQ-IRR-SC-AC. The IC results showed non-uniformity of the signal intensity in the LV wall for the SPECT systems. The lowest IC values were obtained for IQ-IRR-SC-AC, except for septal position, where an underestimation of the signal intensity was revealed. The NC was found to be the highest for IQ-IRR-SC-AC and SPECT-IRR-SC. Additionally, for IQ-IRR-SC-AC, the NC increased in posterior and septal positions compared to IQ-IRR, enabling better perfusion detection capability over short-axis images. IQ-IRR showed performances comparable to SPECT-IRR. The characterization and evaluation perfusion detection capability of the MPI systems enabled the investigation of the systems’ performance and limitations.
Keywords
This publication has 23 references indexed in Scilit:
- National survey to set diagnostic reference levels in nuclear medicine single photon emission imaging in CroatiaPhysica Medica, 2020
- Optimal 99mTc activity ratio in the single-day stress-rest myocardial perfusion imaging protocol: A multi-SPECT phantom studyJournal of Nuclear Cardiology, 2020
- Agreement between left ventricular ejection fraction assessed in patients with gated IQ-SPECT and conventional imagingJournal of Nuclear Cardiology, 2018
- IQ·SPECT technology and its clinical applications using multicenter normal databasesAnnals of Nuclear Medicine, 2017
- Comparative analysis of iterative reconstruction algorithms with resolution recovery and new solid state cameras dedicated to myocardial perfusion imagingPhysica Medica, 2017
- Differences in polar-map patterns using the novel technologies for myocardial perfusion imagingJournal of Nuclear Cardiology, 2016
- The importance of a correct positioning of the heart using IQ-SPECT system with multifocal collimators in myocardial perfusion imaging: A phantom studyJournal of Nuclear Cardiology, 2015
- A performance comparison of novel cadmium–zinc–telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuationAnnals of Nuclear Medicine, 2015
- Comparative analysis of iterative reconstruction algorithms with resolution recovery for cardiac SPECT studies. A multi-center phantom studyJournal of Nuclear Cardiology, 2014
- Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imagingJournal of Nuclear Cardiology, 2013