Evaluation and Prediction of Human Lumbar Vertebrae Endplate Mechanical Properties Using Indentation and Computed Tomography
- 21 June 2018
- journal article
- research article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (10) , 101011
Abstract
Current implant materials and designs used in spinal fusion show high rates of subsidence. There is currently a need for a method to predict the mechanical properties of the endplate using clinically available tools. The purpose of this study was to develop a predictive model of the mechanical properties of the vertebral endplate at a scale relevant to the evaluation of current medical implant designs and materials. Twenty vertebrae (10 L1 and 10 L2) from 10 cadavers were studied using dual-energy X-ray absorptiometry to define bone status (normal, osteopenic, or osteoporotic) and computed tomography (CT) to study endplate thickness (μm), density (mg/mm3), and mineral density of underlying trabecular bone (mg/mm3) at discrete sites. Apparent Oliver–Pharr modulus, stiffness, maximum tolerable pressure (MTP), and Brinell hardness were measured at each site using a 3 mm spherical indenter. Predictive models were built for each measured property using various measures obtained from CT and demographic data. Stiffness showed a strong correlation between the predictive model and experimental values (r = 0.85), a polynomial model for Brinell hardness had a stronger predictive ability compared to the linear model (r = 0.82), and the modulus model showed weak predictive ability (r = 0.44), likely due the low indentation depth and the inability to image the endplate at that depth (≈0.15 mm). Osteoporosis and osteopenia were found to be the largest confounders of the measured properties, decreasing them by approximately 50%. It was confirmed that vertebral endplate mechanical properties could be predicted using CT and demographic indices.Keywords
Funding Information
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (1R21AR065713)
This publication has 29 references indexed in Scilit:
- Results and complications after 2-level axial lumbar interbody fusion with a minimum 2-year follow-upJournal of Neurosurgery: Spine, 2012
- Morphology of the human vertebral endplateJournal of Orthopaedic Research, 2011
- Evaluation of spinal instrumentation rod bending characteristics for in‐situ contouringJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2011
- PMS17 BUDGET IMPACT OF NEW RHBMP-2 FORMULATION IN PATIENTS UNDERGOING POSTEROLATERAL SPINAL FUSION PROCEDURES FOR DEGENERATIVE DISC DISEASE IN RANDOMIZED CONTROLLED TRIAL (RCT)Value in Health, 2010
- Elastic modulus of Ti–6Al–4V–xB alloys with B up to 0.55wt.%Scripta Materialia, 2010
- Mechanical property determination of bone through nano- and micro-indentation testing and finite element simulationJournal of Biomechanics, 2008
- Biomechanical Rationale for Using Polyetheretherketone (PEEK) Spacers for Lumbar Interbody Fusion–A Finite Element StudySpine, 2006
- Measurement of hardness and elastic modulus by instrumented indentation: Advances in understanding and refinements to methodologyJournal of Materials Research, 2004
- Finite Element Modeling of the Human Thoracolumbar SpineSpine, 2003
- An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experimentsJournal of Materials Research, 1992