R. Dana Carpenter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
R. Dana Carpenter has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Christopher M. Yakacki
Department of Mechanical Engineering, University of Colorado, Denver, CO 80217, USA
2 shared publications- Andriy Noshchenko
Department of Orthopedics, University of Colorado, Anschutz Medical Campus, 13001 E 17th Avenue, Building 500, Mail Stop 432, Aurora, CO 80045
1 shared publication - Brecca M. M. Gaffney
Department of Mechanical Engineering, University of Colorado Denver, Denver, CO, USA
1 shared publication Brett S. Klosterhoff
Parker H. Petit Institute for Bioengineering & Bioscience, Georgia Institute of Technology, Atlanta, GA, USA; George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication- Carl Pieter Frick
Department of Mechanical Engineering, University of Wyoming, Laramie, WY 82071, USA
1 shared publication Carole Schreck
Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, United States
1 shared publication
Latest Publications
- 7 February 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 182, 112569
Estimating temporal bone-implant stresses in patients with bone-anchored lower limbs
- 7 February 2025
- Published by Elsevier in Journal of Biomechanics
- Vol. 182, 112569
Estimating temporal bone-implant stresses in patients with bone-anchored lower limbs
- Open Access
- 13 May 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (10) , 1-27
Implant Strength Contributes to the Osseointegration Strength of Porous Metallic Materials
Creating the optimal environment for effective and long term osseointegration is a heavily researched and sought-after design criteria for orthopedic implants. A validated multimaterial finite element (FE) model was developed to replicate and understand the results of an experimental in vivo push-out osseointegration model. The FE model results closely predicted global force (at 0.5 mm) and stiffness for the 50–90% porous implants with an r2 of 0.97 and 0.98, respectively. In addition, the FE global force at 0.5 mm showed a correlation to the maximum experimental forces with an r2 of 0.90. The highest porosity implants (80–90%) showed lower stiffnesses and more equitable load sharing but also failed at lower a global force level than the low porosity implants (50–70%). The lower strength of the high porosity implants caused premature plastic deformation of the implant itself during loading as well as significant deformations in the ingrown and surrounding bone, resulting in lower overall osseointegration strength, consistent with experimental measurements. The lower porosity implants showed a balance of sufficient bony ingrowth to support osseointegration strength coupled with implant mechanical properties to circumvent significant implant plasticity and collapse under the loading conditions. Together, the experimental and finite element modeling results support an optimal porosity in the range of 60–70% for maximizing osseointegration with current structure and loading.
- 13 May 2024
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 146 (10) , 1-27
Open AccessImplant Strength Contributes to the Osseointegration Strength of Porous Metallic Materials
Creating the optimal environment for effective and long term osseointegration is a heavily researched and sought-after design criteria for orthopedic implants. A validated multimaterial finite element (FE) model was developed to replicate and understand the results of an experimental in vivo push-out osseointegration model. The FE model results closely predicted global force (at 0.5 mm) and stiffness for the 50–90% porous implants with an r2 of 0.97 and 0.98, respectively. In addition, the FE global force at 0.5 mm showed a correlation to the maximum experimental forces with an r2 of 0.90. The highest porosity implants (80–90%) showed lower stiffnesses and more equitable load sharing but also failed at lower a global force level than the low porosity implants (50–70%). The lower strength of the high porosity implants caused premature plastic deformation of the implant itself during loading as well as significant deformations in the ingrown and surrounding bone, resulting in lower overall osseointegration strength, consistent with experimental measurements. The lower porosity implants showed a balance of sufficient bony ingrowth to support osseointegration strength coupled with implant mechanical properties to circumvent significant implant plasticity and collapse under the loading conditions. Together, the experimental and finite element modeling results support an optimal porosity in the range of 60–70% for maximizing osseointegration with current structure and loading.
- Open Access
- 16 November 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (11) , e0288049
Effect of intramedullary nail stiffness on load-sharing in tibiotalocalcaneal arthrodesis: A patient-specific finite element study
Tibiotalocalcaneal (TTC) arthrodesis is a procedure to treat severe ankle and subtalar arthropathy by providing pain free and stable fusion using IM nails. These nails can be manufactured with multiple materials and some feature the ability to dynamize the arthrodesis construct. However, the impact of IM nail material and nail dynamization on load-sharing and in the setting of bone resorption have not been quantified. This work utilized a patient-specific finite element analysis model of TTC arthrodesis to investigate IM nails with differing material moduli and the impact of nail dynamization on load-sharing and intersegmental compression in the setting of bone resorption. Each nail was virtually inserted into a patient-specific model of a hindfoot, which was segmented into the three bones of the TTC complex and assigned material properties based on the densitometry of the bone. Compression, amount of load-sharing, and stress distributions after simulated bone resorption were quantified and compared between the varying IM nails. Simulations revealed that bone segments were only subjected to 17% and 22% of dynamic gait forces in the titanium and carbon fiber nail constructs, whereas the pseudoelastic NiTi nail constructs allowed for 67% of the same. The titanium and carbon fiber nails lost all initial compression in less than 0.13mm of bone resorption, whereas the NiTi nail maintained compression through all simulated values of bone resorption. These data highlight the poor load-sharing of static nail TTC arthrodesis constructs and the ability of a pseudoelastic IM nail construct to maintain intersegmental compression when challenged with bone resorption.
- 16 November 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (11) , e0288049
Open AccessEffect of intramedullary nail stiffness on load-sharing in tibiotalocalcaneal arthrodesis: A patient-specific finite element study
Tibiotalocalcaneal (TTC) arthrodesis is a procedure to treat severe ankle and subtalar arthropathy by providing pain free and stable fusion using IM nails. These nails can be manufactured with multiple materials and some feature the ability to dynamize the arthrodesis construct. However, the impact of IM nail material and nail dynamization on load-sharing and in the setting of bone resorption have not been quantified. This work utilized a patient-specific finite element analysis model of TTC arthrodesis to investigate IM nails with differing material moduli and the impact of nail dynamization on load-sharing and intersegmental compression in the setting of bone resorption. Each nail was virtually inserted into a patient-specific model of a hindfoot, which was segmented into the three bones of the TTC complex and assigned material properties based on the densitometry of the bone. Compression, amount of load-sharing, and stress distributions after simulated bone resorption were quantified and compared between the varying IM nails. Simulations revealed that bone segments were only subjected to 17% and 22% of dynamic gait forces in the titanium and carbon fiber nail constructs, whereas the pseudoelastic NiTi nail constructs allowed for 67% of the same. The titanium and carbon fiber nails lost all initial compression in less than 0.13mm of bone resorption, whereas the NiTi nail maintained compression through all simulated values of bone resorption. These data highlight the poor load-sharing of static nail TTC arthrodesis constructs and the ability of a pseudoelastic IM nail construct to maintain intersegmental compression when challenged with bone resorption.
- 21 June 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (10) , 101011
Evaluation and Prediction of Human Lumbar Vertebrae Endplate Mechanical Properties Using Indentation and Computed Tomography
Current implant materials and designs used in spinal fusion show high rates of subsidence. There is currently a need for a method to predict the mechanical properties of the endplate using clinically available tools. The purpose of this study was to develop a predictive model of the mechanical properties of the vertebral endplate at a scale relevant to the evaluation of current medical implant designs and materials. Twenty vertebrae (10 L1 and 10 L2) from 10 cadavers were studied using dual-energy X-ray absorptiometry to define bone status (normal, osteopenic, or osteoporotic) and computed tomography (CT) to study endplate thickness (μm), density (mg/mm3), and mineral density of underlying trabecular bone (mg/mm3) at discrete sites. Apparent Oliver–Pharr modulus, stiffness, maximum tolerable pressure (MTP), and Brinell hardness were measured at each site using a 3 mm spherical indenter. Predictive models were built for each measured property using various measures obtained from CT and demographic data. Stiffness showed a strong correlation between the predictive model and experimental values (r = 0.85), a polynomial model for Brinell hardness had a stronger predictive ability compared to the linear model (r = 0.82), and the modulus model showed weak predictive ability (r = 0.44), likely due the low indentation depth and the inability to image the endplate at that depth (≈0.15 mm). Osteoporosis and osteopenia were found to be the largest confounders of the measured properties, decreasing them by approximately 50%. It was confirmed that vertebral endplate mechanical properties could be predicted using CT and demographic indices.
- 21 June 2018
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 140 (10) , 101011
Evaluation and Prediction of Human Lumbar Vertebrae Endplate Mechanical Properties Using Indentation and Computed Tomography
Current implant materials and designs used in spinal fusion show high rates of subsidence. There is currently a need for a method to predict the mechanical properties of the endplate using clinically available tools. The purpose of this study was to develop a predictive model of the mechanical properties of the vertebral endplate at a scale relevant to the evaluation of current medical implant designs and materials. Twenty vertebrae (10 L1 and 10 L2) from 10 cadavers were studied using dual-energy X-ray absorptiometry to define bone status (normal, osteopenic, or osteoporotic) and computed tomography (CT) to study endplate thickness (μm), density (mg/mm3), and mineral density of underlying trabecular bone (mg/mm3) at discrete sites. Apparent Oliver–Pharr modulus, stiffness, maximum tolerable pressure (MTP), and Brinell hardness were measured at each site using a 3 mm spherical indenter. Predictive models were built for each measured property using various measures obtained from CT and demographic data. Stiffness showed a strong correlation between the predictive model and experimental values (r = 0.85), a polynomial model for Brinell hardness had a stronger predictive ability compared to the linear model (r = 0.82), and the modulus model showed weak predictive ability (r = 0.44), likely due the low indentation depth and the inability to image the endplate at that depth (≈0.15 mm). Osteoporosis and osteopenia were found to be the largest confounders of the measured properties, decreasing them by approximately 50%. It was confirmed that vertebral endplate mechanical properties could be predicted using CT and demographic indices.
- Open Access
- 25 April 2018
- Published by The Royal Society in Royal Society Open Science
- Vol. 5 (4) , 172067
New Guinea bone daggers were engineered to preserve social prestige
Bone daggers were once widespread in New Guinea. Their purpose was both symbolic and utilitarian; they functioned as objects of artistic expression with the primary function of stabbing and killing people at close quarters. Most daggers were shaped from the tibiotarsus of cassowaries, but daggers shaped from the femora of respected men carried greater social prestige. The greater cross-sectional curvature of human bone daggers indicates superior strength, but the material properties of cassowary bone are unknown. It is, therefore, uncertain whether the macrostructure of human bone daggers exists to compensate for inferior material properties of human femora or to preserve the symbolic value of a prestigious object. To explore this question, we used computed tomography to examine the structural mechanics of 11 bone daggers, 10 of which are museum-accessioned objects of art. We found that human and cassowary bones have similar material properties and that the geometry of human bone daggers results in higher moments of inertia and a greater resistance to bending. Data from finite-element models corroborated the superior mechanical performance of human bone daggers, revealing greater resistance to larger loads with fewer failed elements. Taken together, our findings suggest that human bone daggers were engineered to preserve symbolic capital, an outcome that agrees well with the predictions of signalling theory.
- 25 April 2018
- Published by The Royal Society in Royal Society Open Science
- Vol. 5 (4) , 172067
Open AccessNew Guinea bone daggers were engineered to preserve social prestige
Bone daggers were once widespread in New Guinea. Their purpose was both symbolic and utilitarian; they functioned as objects of artistic expression with the primary function of stabbing and killing people at close quarters. Most daggers were shaped from the tibiotarsus of cassowaries, but daggers shaped from the femora of respected men carried greater social prestige. The greater cross-sectional curvature of human bone daggers indicates superior strength, but the material properties of cassowary bone are unknown. It is, therefore, uncertain whether the macrostructure of human bone daggers exists to compensate for inferior material properties of human femora or to preserve the symbolic value of a prestigious object. To explore this question, we used computed tomography to examine the structural mechanics of 11 bone daggers, 10 of which are museum-accessioned objects of art. We found that human and cassowary bones have similar material properties and that the geometry of human bone daggers results in higher moments of inertia and a greater resistance to bending. Data from finite-element models corroborated the superior mechanical performance of human bone daggers, revealing greater resistance to larger loads with fewer failed elements. Taken together, our findings suggest that human bone daggers were engineered to preserve symbolic capital, an outcome that agrees well with the predictions of signalling theory.
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 83-92
Finite element analysis of a pseudoelastic compression-generating intramedullary ankle arthrodesis nail
- 1 September 2016
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 62, 83-92
Finite element analysis of a pseudoelastic compression-generating intramedullary ankle arthrodesis nail
- Open Access
- 4 July 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (10) , 1225-1232
Inter-scanner differences in in vivo QCT measurements of the density and strength of the proximal femur remain after correction with anthropomorphic standardization phantoms
In multicenter studies and longitudinal studies that use two or more different quantitative computed tomography (QCT) imaging systems, anthropomorphic standardization phantoms (ASPs) are used to correct inter-scanner differences and allow pooling of data. In this study, in vivo imaging of 20 women on two imaging systems was used to evaluate inter-scanner differences in hip integral BMD (iBMD), trabecular BMD (tBMD), cortical BMD (cBMD), femoral neck yield moment (My) and yield force (Fy), and finite-element derived strength of the femur under stance (FEstance) and fall (FEfall) loading. Six different ASPs were used to derive inter-scanner correction equations. Significant (p<0.05) inter-scanner differences were detected in all measurements except My and FEfall, and no ASP-based correction was able to reduce inter-scanner variability to corresponding levels of intra-scanner precision. Inter-scanner variability was considerably higher than intra-scanner precision, even in cases where the mean inter-scanner difference was statistically insignificant. A significant (p<0.01) effect of body size on inter-scanner differences in BMD was detected, demonstrating a need to address the effects of body size on QCT measurements. The results of this study show that significant inter-scanner differences in QCT-based measurements of BMD and bone strength can remain even when using an ASP.
- 4 July 2014
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 36 (10) , 1225-1232
Open AccessInter-scanner differences in in vivo QCT measurements of the density and strength of the proximal femur remain after correction with anthropomorphic standardization phantoms
In multicenter studies and longitudinal studies that use two or more different quantitative computed tomography (QCT) imaging systems, anthropomorphic standardization phantoms (ASPs) are used to correct inter-scanner differences and allow pooling of data. In this study, in vivo imaging of 20 women on two imaging systems was used to evaluate inter-scanner differences in hip integral BMD (iBMD), trabecular BMD (tBMD), cortical BMD (cBMD), femoral neck yield moment (My) and yield force (Fy), and finite-element derived strength of the femur under stance (FEstance) and fall (FEfall) loading. Six different ASPs were used to derive inter-scanner correction equations. Significant (p<0.05) inter-scanner differences were detected in all measurements except My and FEfall, and no ASP-based correction was able to reduce inter-scanner variability to corresponding levels of intra-scanner precision. Inter-scanner variability was considerably higher than intra-scanner precision, even in cases where the mean inter-scanner difference was statistically insignificant. A significant (p<0.01) effect of body size on inter-scanner differences in BMD was detected, demonstrating a need to address the effects of body size on QCT measurements. The results of this study show that significant inter-scanner differences in QCT-based measurements of BMD and bone strength can remain even when using an ASP.
- 16 March 2013
- Published by Springer Nature in Current Osteoporosis Reports
- Vol. 11 (2) , 156-162
Finite Element Analysis of the Hip and Spine Based on Quantitative Computed Tomography
Quantitative computed tomography (QCT) provides three-dimensional information about bone geometry and the spatial distribution of bone mineral. Images obtained with QCT can be used to create finite element models, which offer the ability to analyze bone strength and the distribution of mechanical stress and physical deformation. This approach can be used to investigate different mechanical loading scenarios (stance and fall configurations at the hip, for example) and to estimate whole bone strength and the relative mechanical contributions of the cortical and trabecular bone compartments. Finite element analyses based on QCT images of the hip and spine have been used to provide important insights into the biomechanical effects of factors such as age, sex, bone loss, pharmaceuticals, and mechanical loading at sites of high clinical importance. Thus, this analysis approach has become an important tool in the study of the etiology and treatment of osteoporosis at the hip and spine.
- 16 March 2013
- Published by Springer Nature in Current Osteoporosis Reports
- Vol. 11 (2) , 156-162
Finite Element Analysis of the Hip and Spine Based on Quantitative Computed Tomography
Quantitative computed tomography (QCT) provides three-dimensional information about bone geometry and the spatial distribution of bone mineral. Images obtained with QCT can be used to create finite element models, which offer the ability to analyze bone strength and the distribution of mechanical stress and physical deformation. This approach can be used to investigate different mechanical loading scenarios (stance and fall configurations at the hip, for example) and to estimate whole bone strength and the relative mechanical contributions of the cortical and trabecular bone compartments. Finite element analyses based on QCT images of the hip and spine have been used to provide important insights into the biomechanical effects of factors such as age, sex, bone loss, pharmaceuticals, and mechanical loading at sites of high clinical importance. Thus, this analysis approach has become an important tool in the study of the etiology and treatment of osteoporosis at the hip and spine.