Accuracy of metabolic volume and total glycolysis among six threshold-based target segmentation algorithms
- 11 June 2020
- journal article
- research article
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 34 (8) , 583-594
Abstract
Objective This study aimed to evaluate the accuracy of six threshold-based segmentation methods with different target-to-background ratios (TBR), images with different voxel sizes and image noise, in measuring metabolic volume (MV) and total glycolysis (TG). Methods A standard body phantom consisting of six spheres (inner diameters of 37, 28, 22, 17, 13, and 10 mm) was filled with 18F-FDG solution. The background radioactivity level was 2.65 kBq/mL, and the TBRs were 4 and 8. PET data were acquired for 30 min with list mode. PET data for 30 and 3 min were reconstructed with a three-dimensional ordered subset expectation maximization algorithm plus time-of-flight information with images with 2 and 4 mm isotropic voxels. The six methods examined were absolute standardized uptake value (SUV) of 2.5 (SUV2.5), 41%, 50%, adaptive 41%, and adaptive 50% thresholds of maximum SUV (Th41, Th50, ThA41, and ThA50, respectively); and the contrast-oriented algorithm (ThCOA). Segmented MV and TG were compared with the actual inner volume and expressed as percentages (%MVseg and %TGseg, respectively). In addition, the segmented MV was converted to the diameter, and the differences of it from the reference diameter were compared among six methods. Results The ThCOA method yielded the most accurate measurements of %MVseg and %TGseg; the difference between %MVseg or %TGseg and its reference were smaller than 10% in 30-min and 15% in 3-min images, but the segmented contour was almost the same as the reference diameter. Measurements with Th50 and ThCOA were highly accurate for both %MVseg and %TGseg in the large spheres, and the adaptive threshold methods, including ThA41, ThA50, and ThCOA, were also highly accurate in the small spheres. The voxel sizes affected the accuracy of %MVseg and %TGseg with a TBR of 4 in any threshold-based methods. Conclusions Of the six threshold-based segmentation methods studied, ThCOA was the most accurate method for evaluating MV and TG and had only minor dependence on TBRs and sphere size. The small voxel sizes improved the variation of the accuracy in low TBR.Keywords
This publication has 24 references indexed in Scilit:
- FDG PET/CT for metastatic squamous cell carcinoma of unknown primary of the head and neckOral Oncology, 2019
- 18F-FDG PET/CT for Staging and Restaging of Breast CancerJournal of Nuclear Medicine, 2016
- Prognostic value of volumetric parameters of 18F-FDG PET in non-small-cell lung cancer: a meta-analysisEuropean Journal of Nuclear Medicine and Molecular Imaging, 2014
- Prognostic Value of Metabolic Tumor Volume and Total Lesion Glycolysis on Preoperative 18F-FDG PET/CT in Patients with Pancreatic CancerJournal of Nuclear Medicine, 2014
- FDG PET/CT metabolic tumor volume and total lesion glycolysis predict prognosis in patients with advanced lung adenocarcinomaJournal of Cancer Research and Clinical Oncology, 2013
- 18F-FDG PET/CT Metabolic Tumor Volume and Total Lesion Glycolysis Predict Outcome in Oropharyngeal Squamous Cell CarcinomaJournal of Nuclear Medicine, 2012
- Clinical evidence on PET–CT for radiation therapy planning in head and neck tumoursRadiotherapy and Oncology, 2010
- 18F-FDG PET/CT for early prediction of response to neoadjuvant chemotherapy in breast cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- Dual-Modality Imaging: Combining Anatomy and FunctionJournal of Nuclear Medicine, 2008
- PET/CT: a new imaging technology in nuclear medicineEuropean Journal of Nuclear Medicine and Molecular Imaging, 2003