Performance Study of Personal Inhalable Aerosol Samplers at Ultra-Low Wind Speeds
Open Access
- 10 October 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Annals of Occupational Hygiene
- Vol. 56 (2) , 207-220
Abstract
The assessment of personal inhalable aerosol samplers in a controlled laboratory setting has not previously been carried out at the ultra-low wind speed conditions that represent most modern workplaces. There is currently some concern about whether the existing inhalable aerosol convention is appropriate at these low wind speeds and an alternative has been suggested. It was therefore important to assess the performance of the most common personal samplers used to collect the inhalable aerosol fraction, especially those that were designed to match the original curve. The experimental set-up involved use of a hybrid ultra-low speed wind tunnel/calm air chamber and a rotating, heating breathing mannequin to measure the inhalable fraction of aerosol exposure. The samplers that were tested included the Institute of Occupational Medicine (IOM), Button, and GSP inhalable samplers as well as the closed-face cassette sampler that has been (and still is) widely used by occupational hygienists in many countries. The results showed that, down to ∼0.2 m s−1, the samplers matched the current inhalability criterion relatively well but were significantly greater than this at the lowest wind speed tested. Overall, there was a significant effect of wind speed on sampling efficiency, with lower wind speeds clearly associated with an increase in sampling efficiency.Keywords
This publication has 19 references indexed in Scilit:
- Laboratory Study of Selected Personal Inhalable Aerosol SamplersAnnals of Occupational Hygiene, 2010
- On Wiping the Interior Walls of 37-mm Closed-Face Cassettes: An OSHA PerspectiveJournal of Occupational and Environmental Hygiene, 2009
- A Headset-Mounted Mini Sampler for Measuring Exposure to Welding Aerosol in the Breathing ZoneAnnals of Work Exposures and Health, 2009
- The Need for an International Sampling Convention for Inhalable Dust in Calm AirJournal of Occupational and Environmental Hygiene, 2006
- Field Comparison of 37-mm Closed-Face Cassettes and IOM SamplersApplied Occupational and Environmental Hygiene, 2002
- Evaluation of personal aerosol samplers challenged with large particlesJournal of Aerosol Science, 2001
- Performance Characteristics of the Button Personal Inhalable Aerosol SamplerAIHA Journal, 2000
- AEROSOL INHALABILITY IN LOW AIR MOVEMENT ENVIRONMENTSJournal of Aerosol Science, 1999
- THE SAMPLING EFFICIENCY OF PERSONAL INHALABLE AEROSOL SAMPLERS IN LOW AIR MOVEMENT ENVIRONMENTSJournal of Aerosol Science, 1999
- A COLLABORATIVE EUROPEAN STUDY OF PERSONAL INHALABLE AEROSOL SAMPLER PERFORMANCEAnnals of Occupational Hygiene, 1997